Electrical connection
DANGER due to electric shock.
Switch off the mains fuse before working on the electrical equipment. Observe safety instruction supplementary sheet.
DANGER due to short circuit/fire if moisture penetrates into the terminal compartment. Electronics cover not flat/tight if installed incorrectly.
Lead the cable sheathing into the terminal compartment as little as possible and sealed. Observe the permissible length of individual cable cores.
- Switch off mains fuse, secure against being accidentally switched back on and position a warning sign.
- Only lay single cable cores in the fan. To do this, remove power cable sheathing over a length of 100 mm. Strip single cable cores to 9 to 10 mm.
Permissible length of individual cable cores

13 | Spring terminal |
14 | Circuit diagram |
- Connect power cable to spring terminal → ECA 100 ipro circuit diagrams.
Appendix.
- Check fit/tightness of the cable grommet.
- If necessary, connect a speed controller (STX 1,5).
The standard model of ECA 100 ipro can be operated in two levels with double switches. Without a double switch, the fan can be operated either at power level 1 or at power level 2 → Associated switching variants