Ambient conditions, technical data
- Permissible maximum temperature of air medium + 40 °C.
- Sufficient supply air intake must be ensured during operation with room-air-dependent fireplaces. The maximum permitted pressure difference per residential unit is 4 Pa.
- Resistance to interference according to EN 55014-2 depending on pulse shape and energy component 1000 to 4000 V. If operating with fluorescent tubes, extra interference suppression measures are needed (L or C components or RC modules, protection diodes, varistors) because these values may be exceeded.
- Storage: Store unit exclusively in a dry location (-20 to +50 °C).
All variants
Rated voltage | 230 V |
Power frequency | 50 Hz |
Protection rating of the fan | IP X5 |
Weight | 1.6 kg |
Variants B and KB (movement)
Reach | 5 m |
Horizontal / vertical detection range | 100° / 82° |
Variants RC, RCH, KRC, KRCH (radio)
Radio components: | 868.35 MHz |
Operating distances in the building are dependent on the building materials used: |
|
For more technical data → rating plate.
For characteristic curves → ECA 150 ipro.