ECA 150 ipro RC, RCH, KRC and KRCH (radio variants)

DS RC radio switch (EnOcean)

DS RC double rocker switch: Up to 5 DS RC per fan can be taught-in. Left rocker switch for on/off, right rocker switch for switching the power level. The rocker switches must be taught in separately. Always teach in the radio switch for the fan that is located in the same room as the switch. Automatic humidity control for RCH/KRCH with priority. Switching with DS RC possible at any time during humidity operating mode.

Radio window contact (EnOcean)

Radio window contact for fan on/off when window open or window closed. A maximum of 2 radio window contacts per fan can be taught in. Fan off when the window is opened, fan on after reduced level time of 30 minutes or when the window is closed. Fan on with radio switch possible at any time (radio switch with priority). Automatic humidity control for RCH/KRCH. Switching with radio window contact possible at any time during humidity operating mode.