Covers: Functions

 

ER-A

ER-AK

ER-AH

ER-AB

ER-AK NFC

ER-AH NFC

ER-AB NFC

Parameterisable via Maico@NFC app

 

 

 

 

Filter change indicator
(6 months) with TimeStrip

 

 

 

 

 

 

Filter change indicator
(6 months) with LED

 

Control with time module

 

Control with fully automatic humidity control: Air extraction takes place automatically if the specified switch-on humidity is exceeded.

 

 

 

 

 

Control with manual humidity control: Air extraction takes place when humidity switch-on points 1 and 2 are exceeded

 

 

 

 

 

 

Control with motion detector. Full load level after motion is detected (range motion sensor is 5 m)

 

 

 

 

 

Barrier-free product, (automatic ON/OFF)

 

 

 

Not speed-controllable

Electrical plug-in connection for quick connection of the ER EC with ER GH and ER-AK/-AK NFC, ER-AH/-AH NFC or ER-AB/-AB NFC with the ER EC 2.1 fan insert

 

Base load flow rate: 30 m³/h for continuous operation

●*

●*

●*

●*

●*

●*

●*

Flow rate of the base load and full load levels can be set

 

Additional adjustable base load
flow rates: 20 m³/h, 40 m³/h, 60 m³/h or 100 m³/h and in full load: 20 m³/h, 30 m³/h, 40 m³/h or 100 m³/h

 

●***

 

 

 

Additional adjustable base load flow rates: 15-100 m³/h and full load 15-100 m³/h

 

 

 

 

●***

Full load level on/off via light switch or separate switch. For manual operation (e.g. using a light switch), the start delay and run-on time apply.

Full load level 60 m³/h, start delay of 60 s, run-on time fixed at 15 min.

 

 

 

 

 

 

Full load operation (60 m³/h), start delay can be set with 0, 30, 60*, 90 or 120 seconds

 

●**

 

 

 

Full load operation (60 m³/h), start delay can be set with 0–120 seconds in 5-second increments

 

 

 

 

●**

Run-on time of the full load level can be set for 0, 3, 6, 15*, 24 or 30 minutes

 

 

 

 

Run-on time of the full load level adjustable 0–30 minutes in 1-minute increments

 

 

 

 

Adjustable interval control for ventilating rooms that are not regularly used. Time interval can be set for 0*, 1, 2, 4, 6 or 12 hours, operating time per interval 10 minutes

 

 

 

 

Adjustable interval control for ventilating rooms that are not regularly used. Time interval adjustable 0–24 hours in 1 hour increments, operating time adjustable at intervals.

 

 

 

 

Operating time adjustable at intervals of 10–60 minutes in 10-minute increments

 

 

 

 

Interval control can be switched off.

 

Switching option: The base load can be switched on or off by an additional switch (Wiring diagrams).

* Factory setting: Tolerance of time details max. ± 5 %.

** For the ER-AB/-AB NFC, the start delay only affects the light switch operation.

*** For ER-AH/-AH NFC humidity control, 15–40 m³/h can be set for base load and 40–100 m³/h for full load.