Technical data for PPB 30

External diameter

DN 160

Length of
wall sleeve

PP 45 RHK: 500 mm
PP 45 RHL: 800 millimeters

Wall thickness

320 – 790 mm

Air filter

Filter class ISO 16890
ISO coarse 45 % (G3) 2 items

Air volume/unit

26 m³/h

Degree of protection

IP X4

Sound pressure level: at distance of 1 m, free-field conditions (ventilation levels 1 - 5)

18 / 32 / 41 / 45 / 49 dB(A)

Rated voltage

PPB 30 O, PPB 30 K: 12 V
PPB 30 RC: 230 V

Power frequency

50/60 Hz

Volumetric flow in heat recovery mode, ventilation levels 1 to 5

5 / 12 / 18 / 22 / 26 m³/h

Volumetric flow in exhaust air mode (no heat recovery unit)

45 m³/h

Power consumption

1.7 / 2.5 / 3.4 / 4.4 / 5.3 W

Degree of heat provision

73.3 % (level 3)

SPI

0.19 W / (m³/h)

SEC value

A (-39,71 kWh / (m²*a))

Permissible ducting lengths with wired connection

From star point, max. 25 m per ventilation unit

Weight of slide-in module, cpl.

3.6 kg

Radio components: Frequency range (in acc. with EN 300220-1)

868.35 MHz

Radio receiver with internal antenna

Do not mount on the wall side of the transmitter

“Wireless” operating distances in the building are dependent on the building materials used:

 

up to:

DS 45 RC PP 45 RC

30 m

PP 45 EO PP 45 RC

30 m

PP 45 RC PP 45 RC

30 m

With signal amplification on EnOcean radio sensors and radio switches with EEP protocol

40 m

For more technical data → rating plate.