Setting signal amplification (repeater)

The repeater function (signal amplification) is available for EnOcean radio sensors and radio switches with EEP protocol. No signal amplification is possible between the PP 45 and PPB 30 ventilation units (internal unit protocol).

Setting values

Off
Level 1: Original telegrams are amplified
Level 2: Original telegrams, as well as telegrams that have already been amplified, are amplified.

Switching on signal amplifier

  1. Activate teach-in mode on the receiver (master unit). The 3 LEDs flash.
  2. Press the TEACH button briefly 3x. The 3 LEDs flash 3x and then the red LED flashes once (periodic process).
  1. The Repeater sub-menu (→ Radio telegram program levels) is activated. The basic setting is Repeater OFF.
  1. Press the TEACH button briefly x times.
  1. Press 1x: Repeater level 1, 3 LEDs flash 3x and then the red LED flashes 2x.
  2. Press 2x: Repeater level 2, 3 LEDs flash 3x and then the red LED flashes 3x.
  3. When the button is pressed 3x, the loop starts again from Repeater OFF.
  1. Press the TEACH key (≥ 5 seconds) until the LEDs on the ventilation unit light up for an extended period. The setting is saved.