PP 45 RC / PPB 30 RC fault messages


Red LED (*) | Malfunction |
| Internal error in control Fault LED in alternation: lit up for extended period and then flashes briefly 1x. Fault rectification: Ensure that no voltage is present, restart the unit. To reset the unit, press:
|
| Master-slave communication Fault LED in alternation: lit up for extended period and then flashes briefly 2x. Fault rectification: Check communication paths for radio signals and select a different positioning if necessary. If the fault continues to occur, set the last parameter in the PP 45 RC service menu to "Single-room ventilation unit", see installation instructions for PP 45 final installation kit, service menu, chapter 9.4. |
| Internal sensor defective (I2C) Fault LED in alternation: lit up for extended period and then flashes briefly 3x. Fault rectification: Check that the sensor is positioned correctly or replace the sensor. |
| External sensor not reporting Fault LED in alternation: lit up for extended period and then flashes briefly 4x. Fault rectification: Check sensor. |
| No communication with the EnOcean module PP 45 EO Fault LED in alternation: lit up for extended period and then flashes briefly 5x. Fault rectification: Check PP 45 EO module for functionality. |
The faults are not acknowledged. The acknowledgement takes place automatically when the fault is rectified.

for 2 seconds.