Connection advice
- Only use approved connection cables, see chapter 5.
- Only carry out the electrical connection in accordance with the connection and wiring diagrams in the associated final installation kit instructions.
- Install the RLS 45 control in a deep flush-mounted box. Always use a deep or double flush-mounted box for wiring several accessory components.
- Strip the connection cables sufficiently.
- Wire the enclosed connector plug to the control cable (see plug sticker).
- Imbalance may arise if the maximum stated cable lengths are exceeded. Observe installation requirements relating to cable lengths and types.
- Permissible cable length can be extended with the PP 45 LT power unit or with RLS 45 K/O slaves.
- PP/PPB/RV 2 ventilation units and RLS 45 K/O controls must only be used outside protection zones 0, 1 and 2. Protect them from moisture and wetness.
The ventilation units and RLS 45 controls are not suitable for outdoor areas.