Permitted operation
Operation of the ventilation unit is permitted:
- in exterior walls with a minimum wall thickness of 365 mm and a maximum wall thickness of 500 mm with sufficient load-bearing capacity.
- in closed rooms (supply and exhaust air rooms), space requirement/working space in front of the unit 0.7 m.
- exactly levelled with a spirit level and aligned with the exterior wall, horizontal installation position (parapet variant) or vertical installation position (soffit variants).
- with permanent electrical installation.
- with correctly installed external grille (drip rail).
- with RLS 45 K comfort control for operating a maximum of 8 RV 2 units.
- with at least 1 pair of units, operation in pairs is recommended. A single RV 2 unit can also be combined with an exhaust air fan in the bathroom/WC. Exhaust air fans with up to 60 m³/h (ER 60 or ECA 100 ipro) are permitted.