Small room fan

AKE 100

Article number: 0084.0220
Manufacturer: MAICO
Automatic cellar dehumidification, DN 100, air volume 92 m³/h
Application examples: Cellar and/or cellar room, Utility room, Drying room, Utility room
Product data sheet
AKE 100 IM0017002.PNG Automatic cellar dehumidification, DN 100, air volume 92 m³/h

Characteristic curve

AKE 100 - Characteristic curve

Dimensioned drawing

AKE 100 - Dimensioned drawing [mm]

  1. Cable entry

AKE 100 - Dimensioned drawing [mm]

Technical data

AKE 100 - Technical data

Article AKE 100
Air flow volume 92 m³/h
Rotating speed 2.500 1/min
Speed controllable
Reversing capacity
SEC average -24,18 kWh/(m²*a)
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Nominal output 8 W
Stand-by power consumption 2 W
Imax 0,06 A
Degree of protection IP X4
Mains cable 5 x 1,5 mm²
Installation site Wall
Type of installation Surface-mounted
Installation position any
Material Synthetic material
Colour Traffic white, similar to RAL 9016
Weight 0,85 kg
Weight including packaging 1,13 kg
Shutter none
Nominal size 100 mm
Cable length 1 m
Width 159 mm
Height 159 mm
Depth 130 mm
Width with packaging 225 mm
Height with packaging 225 mm
Depth with packaging 200 mm
Wall thickness max. 0.85 m (if a 1m length of cable isn't sufficient, please also order the 6m sensor cable)
Airstream temperature at IMax 40 °C
Sound pressure level 32 dB(A) / Distance 3 m, Free-field conditions
Packing unit 1 piece
Range A
GTIN (EAN) 4012799842200
Article number 0084.0220

Accessories / Spare parts

Product description

Productdescription

AKE 100

short description

Automatic cellar dehumidification, DN 100, air volume 92 m³/h

Product description

Model

  • Application area up to approx. 30 m² per fan.
  • Versatile expandability of the system: Connection of a supply air fan (e.g. ECA 11 E) is possible to increase the air exchange.

Features

  • Fully automatic, intelligent cellar dehumidification for the highest demands.
  • Constant comparison of the absolute humidity in the indoor and outdoor areas: Fan ventilates automatically if the absolute humidity in the room is greater than outside.
  • No maintenance and manual control required: Install once and the system works automatically.
  • Other fans without their own dew point control can be connected directly to the AKE, up to a max. of 600 mA, and benefit from the intelligence.
  • Fans > 600 mA can be connected with an additional relay or contactor and thus also dehumidify larger or several rooms via the AKE.
  • Designer cover conceals the inlet.
  • Barrier-free product as the fan switches itself on and off automatically without additional switches.
  • Fan monitors the room humidity.
  • Frost protection function: Switch off the system at inside temperatures below 5 °C.
  • Dry protection function: Switching off the system at a relative humidity of less than 30 %
  • Additional manual operation for 20 min. can be switched on and off by push button.
  • Additional installation of switch for unit not needed.
  • Additional manual continuous operation with switch possible.
  • Status and function displayed using LEDs.
  • Scope of delivery:
    • Fan
    • External shutter
    • Sensors
    • 1m connection cable
  • Housing made of impact-resistant plastic.
  • Thermal overload protection.
  • Protection class II.

Frost protection

  • To prevent the room from cooling down, the AKE has a frost protection function. This means that the fan automatically switches off at inside temperatures of less than 5 °C.

Protection against insufficient humidity

  • To prevent the room from drying out, the AKE has a dry protection function. This means that the fan automatically switches off at a relative room humidity of less than 30 %.

Motor

  • Energy-saving robust motor with ball bearings, maintenance-free.
  • Suitable for continuous operation.

Installation information

  • Simple installation:
    • AKE 100: Core drill hole 105 mm / 120 mm when installing with WH 100 wall sleeve accessory.
    • AKE 150: Core drill hole 155 mm / 170 mm when installing with WH 150 wall sleeve.
  • Wall and ceiling installation is possible

Electrical connection

  • Electrical connection can be either surface- or recessed-mounted.
  • Surface installation for AKE 100 with ECA-DR spacing frame accessory.

Table of contents

Wiring diagram

AKE 100 - Wiring diagram

EF - dehumidification control

T1 - Optional button for manual operation

Z - Connection for optional supply air element, e.g. ECA 11 E



Ab - Fuse protection provided by customer

mE - Manual switching-on option

S - Controller

AL - Exhaust air

ZL - Supply air option



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings