WS 150

Centralised ventilation unit with heat recovery, as left-hand and right-hand version up to 165 m³/h

WS 150 IM0014358.PNG Centralised ventilation unit with heat recovery, as left-hand and right-hand version up to 165 m³/h

Below you can see a direct comparison of the products you have selected. Differences between the products are highlighted in blue.

ArticleWS 150 RWS 150 L
ProduktdetailsProduktdetails
  • On the notes
  • On the notes
Product type Centralised ventilation unit Centralised ventilation unit
Article number: 0095.0057 0095.0058
ModelConnections on the rightConnections on the left
Number of ventilation levels33
Air flow volume70 m³/h - 165 m³/h70 m³/h - 165 m³/h
Volumetric flow constantyesyes
SEC average-38,4 kWh/(m²*a)-38,4 kWh/(m²*a)
Energy efficiency classAA
Type of voltageAlternating currentAlternating current
Rated voltage230 V230 V
Frequency50 Hz/60 Hz50 Hz/60 Hz
SPI value in accordance with DIN EN 13141-7 (A7)0,23 Wh/m³0,23 Wh/m³
Power consumption24 W - 51 W / At 100 Pa counter pressure24 W - 51 W / At 100 Pa counter pressure
Power consumption in accordance with DIN EN 13141-7 (A7)27 W27 W
Stand-by power consumption< 2 W< 2 W
Imax0,5 A0,5 A
Degree of protectionIP 00IP 00
DIBT approvalyesyes
PHI certificationNoNo
Installation siteCellar / Storage tank / Jamb wall / Utility room / Heating roomCellar / Storage tank / Jamb wall / Utility room / Heating room
System typeCentralisedCentralised
Housing materialSheet steel, galvanisedSheet steel, galvanised
Heat exchanger materialAluminiumAluminium
ColourLight greyLight grey
Weight51 kg51 kg
Filter classG4G4
Connection diameter125 mm125 mm
Connection diameter of condensation drain3/4" external thread for connection to a 1/2" hose3/4" external thread for connection to a 1/2" hose
Width1.065 mm1.065 mm
Height460 mm460 mm
Depth400 mm400 mm
Ambient temperature40 °C40 °C
Max. degree of heat provision in accordance with DIN EN 13141-7 (A7)90 %90 %
Heat exchanger construction typeCross-counterflowCross-counterflow
BypassNoNo
Frost protectionExternalExternal
Enthalpy heat exchangerNoNo
Antifreeze circuityesyes
Summer circuitNoNo
Filter monitoringtime controlled with RLS 2 Ftime controlled with RLS 2 F
Humidity controloptional with HY 5, HY 5 I, HY 10 AP, HY 10 UPoptional with HY 5, HY 5 I, HY 10 AP, HY 10 UP
CO2-control (optional)--
Air quality control (optional)EAQ 10/1EAQ 10/1
KNX connection (optional)to be supplied by the customerto be supplied by the customer
MODBUS interfaceNoNo
Control unit included in scope of delivery.NoNo
Control unit (optional)RLS 2 F, RLS 3RLS 2 F, RLS 3
Wireless switch on/off (optional)XE 1, XS 1XE 1, XS 1
EnOcean wireless integration (optional)NoNo
Mobile controlNoNo
Housing emission sound pressure level31 dB(A) / Spacing 1m, sound absorption 10 m²31 dB(A) / Spacing 1m, sound absorption 10 m²
Approval numberZ-51.3-172Z-51.3-172
Packing unit1 piece1 piece
RangeKK
GTIN (EAN)40127999505784012799950585

* Blue markings show the differences between the products.

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Cookies are used on this website, which are necessary for technical reasons, so that we can present users our offers. A cookie that saves your current privacy settings is also used (selection cookie). With the exception of the above-mentioned selection cookie, technically non-essential cookies and tracking mechanisms that enable us to provide you with an optimal user experience as well as customised offers (marketing cookies and tracking mechanisms) are only used if you have previously approved their use by clicking ACCEPT. Details and options for changing your settings at a later date can be found in our cookie settings.

ACCEPT ALL COOKIES Continue with necessary cookies


Acknowledgements | Data protection