WS 170 / WS 170 ET

Centralised ventilation unit with heat recovery, in standard, comfort and bypass versions up to 160 m³/h

WS 170 / WS 170 ET IM0014394.PNG Centralised ventilation unit with heat recovery, in standard, comfort and bypass versions up to 160 m³/h

Below you can see a direct comparison of the products you have selected. Differences between the products are highlighted in blue.

Article

WS 170 R

Centralised ventilation unit with very effective heat recovery through cross-counterflow exchanger, EC motors with constant volumetric flow regulation, supply and exhaust air on the right, 4 x DN 125, including RLS 1 WR control unit, DIBT approval, 40 - 160 m³/h, 23 - 46 m³/h in interval mode, KNX connection possible, 4 x SVR 125 plug connector or 90° B90-125 elbow needed to connect folded spiral-seams ducts (order as accessories)

  • On the notes

WS 170 RET

Centralised ventilation unit with very effective heat recovery through enthalpy cross-counterflow exchanger, EC motors with constant volumetric flow regulation, supply and exhaust air on the right, 4 x DN 125, including RLS 1 WR control unit, 40 - 160 m³/h, 23 - 46 m³/h in interval mode, KNX connection possible, 4 x SVR 125 plug connector or 90° B90-125 elbow needed to connect folded spiral-seams ducts (order as accessories)

  • On the notes

WS 170 L

Centralised ventilation unit with very effective heat recovery through cross-counterflow exchanger, EC motors with constant volumetric flow regulation, supply and exhaust air on the left, 4 x DN 125, including RLS 1 WR control unit, DIBT approval, 40 - 160 m³/h, 23 - 46 m³/h in interval mode, KNX connection possible, 4 x SVR 125 plug connector or 90° B90-125 elbow needed to connect folded spiral-seams ducts (order as accessories)

  • On the notes

WS 170 LET

Centralised ventilation unit with very effective heat recovery through enthalpy cross-counterflow exchanger, EC motors with constant volumetric flow regulation, supply and exhaust air on the left, 4 x DN 125, including RLS 1 WR control unit, 40 - 160 m³/h, 23 - 46 m³/h in interval mode, KNX connection possible, 4 x SVR 125 plug connector or 90° B90-125 elbow needed to connect folded spiral-seams ducts (order as accessories)

  • On the notes

WS 170 KR

Centralised ventilation unit with very effective heat recovery through cross-counterflow exchanger, EC motors with constant volumetric flow regulation, supply and exhaust air on the right, 4 x DN 125, including frost protection heating and RLS 1 WR control unit, DIBT and passive house approval, 40 - 160 m³/h, 23 - 46 m³/h in interval mode, KNX connection possible, 4 x SVR 125 plug connector or 90° B90-125 elbow needed to connect folded spiral-seams ducts (order as accessories)

  • On the notes

WS 170 KRET

Centralised ventilation unit with very effective heat recovery through enthalpy cross-counterflow exchanger, EC motors with constant volumetric flow regulation, supply and exhaust air on the right, 4 x DN 125, including frost protection heating and RLS 1 WR control unit, 40 - 160 m³/h, 23 - 46 m³/h in interval mode, KNX connection possible, 4 x SVR 125 plug connector or 90° B90-125 elbow needed to connect folded spiral-seams ducts (order as accessories)

  • On the notes

WS 170 KL

Centralised ventilation unit with very effective heat recovery through cross-counterflow exchanger, EC motors with constant volumetric flow regulation, supply and exhaust air on the left, 4 x DN 125, including frost protection heating and RLS 1 WR control unit, DIBT and passive house approval, 40 - 160 m³/h, 23 - 46 m³/h in interval mode, KNX connection possible, 4 x SVR 125 plug connector or 90° B90-125 elbow needed to connect folded spiral-seams ducts (order as accessories)

  • On the notes

WS 170 KLET

Centralised ventilation unit with very effective heat recovery through enthalpy cross-counterflow exchanger, EC motors with constant volumetric flow regulation, supply and exhaust air on the left, 4 x DN 125, including frost protection heating and RLS 1 WR control unit, 40 - 160 m³/h, 23 - 46 m³/h in interval mode, KNX connection possible, 4 x SVR 125 plug connector or 90° B90-125 elbow needed to connect folded spiral-seams ducts (order as accessories)

  • On the notes
ArticleWS 170 RWS 170 RETWS 170 LWS 170 LETWS 170 KRWS 170 KRETWS 170 KLWS 170 KLET
ProduktdetailsProduktdetailsProduktdetailsProduktdetailsProduktdetailsProduktdetailsProduktdetailsProduktdetails
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
Product type Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit
Article number: 0095.0081 0095.0110 0095.0082 0095.0111 0095.0083 0095.0112 0095.0084 0095.0113
ModelStandard version - right-handStandard version - right-handStandard version - left-handStandard version - left-handComfort version - right-handComfort version - right-handComfort version - left-handComfort version - left-hand
Number of ventilation levels44444444
Air flow volume40 m³/h - 160 m³/h40 m³/h - 160 m³/h40 m³/h - 160 m³/h40 m³/h - 160 m³/h40 m³/h - 160 m³/h40 m³/h - 160 m³/h40 m³/h - 160 m³/h40 m³/h - 160 m³/h
Volumetric flow constantyesyesyesyesyesyesyesyes
SEC average-36,5 kWh/(m²*a)-34,28 kWh/(m²*a)-36,5 kWh/(m²*a)-34,28 kWh/(m²*a)-36,5 kWh/(m²*a)-34,28 kWh/(m²*a)-36,5 kWh/(m²*a)-34,28 kWh/(m²*a)
Energy efficiency classAAAAAAAA
Type of voltageAlternating currentAlternating currentAlternating currentAlternating currentAlternating currentAlternating currentAlternating currentAlternating current
Rated voltage230 V230 V230 V230 V230 V230 V230 V230 V
Frequency50 Hz/60 Hz50 Hz/60 Hz50 Hz/60 Hz50 Hz/60 Hz50 Hz/60 Hz50 Hz/60 Hz50 Hz/60 Hz50 Hz/60 Hz
SPI value in accordance with DIN EN 13141-7 (A7)0,32 Wh/m³0,28 Wh/m³0,32 Wh/m³0,28 Wh/m³0,32 Wh/m³0,28 Wh/m³0,32 Wh/m³0,28 Wh/m³
Power consumption21 W - 80 W / At 100 Pa counter pressure21 W - 80 W / At 100 Pa counter pressure21 W - 80 W / At 100 Pa counter pressure21 W - 80 W / At 100 Pa counter pressure21 W - 80 W / At 100 Pa counter pressure21 W - 80 W / At 100 Pa counter pressure21 W - 80 W / At 100 Pa counter pressure21 W - 80 W / At 100 Pa counter pressure
Power consumption in accordance with DIN EN 13141-7 (A7)35 W36 W35 W36 W35 W36 W35 W36 W
Stand-by power consumption< 5 W< 5 W< 5 W< 5 W< 5 W< 5 W< 5 W< 5 W
Imax0,5 A0,5 A0,5 A0,5 A0,5 A / With active 4 A frost protection heating0,5 A / With active 4 A frost protection heating0,5 A / With active 4 A frost protection heating0,5 A / With active 4 A frost protection heating
Degree of protectionIP 00IP 00IP 00IP 00IP 00IP 00IP 00IP 00
DIBT approvalyesyesyesyesyesNoyesNo
PHI certificationNoNoNoNoyesNoyesNo
Installation siteBathroom / Kitchen / Cellar / Storage tank / Jamb wall / Utility room / Heating room / HallBathroom / Kitchen / Cellar / Storage tank / Jamb wall / Utility room / Heating room / HallBathroom / Kitchen / Cellar / Storage tank / Jamb wall / Utility room / Heating room / HallBathroom / Kitchen / Cellar / Storage tank / Jamb wall / Utility room / Heating room / HallBathroom / Kitchen / Cellar / Storage tank / Jamb wall / Utility room / Heating room / HallBathroom / Kitchen / Cellar / Storage tank / Jamb wall / Utility room / Heating room / HallBathroom / Kitchen / Cellar / Storage tank / Jamb wall / Utility room / Heating room / HallBathroom / Kitchen / Cellar / Storage tank / Jamb wall / Utility room / Heating room / Hall
System typeCentralisedCentralisedCentralisedCentralisedCentralisedCentralisedCentralisedCentralised
Housing materialSheet steel, powder coatedSheet steel, powder coatedSheet steel, powder coatedSheet steel, powder coatedSheet steel, powder coatedSheet steel, powder coatedSheet steel, powder coatedSheet steel, powder coated
Heat exchanger materialSynthetic materialSynthetic materialSynthetic materialSynthetic materialSynthetic materialSynthetic materialSynthetic materialSynthetic material
Inner coating materialPlastic EPPPlastic EPPPlastic EPPPlastic EPPPlastic EPPPlastic EPPPlastic EPPPlastic EPP
Colourwhite aluminium, similar to RAL 9006white aluminium, similar to RAL 9006white aluminium, similar to RAL 9006white aluminium, similar to RAL 9006white aluminium, similar to RAL 9006white aluminium, similar to RAL 9006white aluminium, similar to RAL 9006white aluminium, similar to RAL 9006
Weight36,5 kg40 kg36,5 kg40 kg42,5 kg46 kg42,5 kg46 kg
Filter classG4 / G4G4 / G4G4 / G4G4 / G4G4 / F7G4 / F7G4 / F7G4 / F7
Connection diameter125 mm125 mm125 mm125 mm125 mm125 mm125 mm125 mm
Connection diameter of condensation drain3/4" hose connection or drain pipe with a diameter of 28 mm3/4" hose connection or drain pipe with a diameter of 28 mm3/4" hose connection or drain pipe with a diameter of 28 mm3/4" hose connection or drain pipe with a diameter of 28 mm3/4" hose connection or drain pipe with a diameter of 28 mm3/4" hose connection or drain pipe with a diameter of 28 mm3/4" hose connection or drain pipe with a diameter of 28 mm3/4" hose connection or drain pipe with a diameter of 28 mm
Width595 mm595 mm595 mm595 mm595 mm595 mm595 mm595 mm
Height820 mm820 mm820 mm820 mm820 mm820 mm820 mm820 mm
Depth375 mm375 mm375 mm375 mm375 mm375 mm375 mm375 mm
Airstream temperature at IMax-20 °C up to 60 °C-20 °C up to 60 °C-20 °C up to 60 °C-20 °C up to 60 °C-20 °C up to 60 °C-20 °C up to 60 °C-20 °C up to 60 °C-20 °C up to 60 °C
Ambient temperature10 °C up to 40 °C10 °C up to 40 °C10 °C up to 40 °C10 °C up to 40 °C10 °C up to 40 °C10 °C up to 40 °C10 °C up to 40 °C10 °C up to 40 °C
Max. degree of heat provision in accordance with DIN EN 13141-7 (A7)95 %90 %95 %90 %95 %90 %95 %90 %
Heat exchanger construction typeCross-counterflowEnthalpy cross-counterflowCross-counterflowEnthalpy cross-counterflowCross-counterflowEnthalpy cross-counterflowCross-counterflowEnthalpy cross-counterflow
BypassNoNoNoNoNoNoNoNo
Frost protectionExternalExternalExternalExternalintegratedintegratedintegratedintegrated
Enthalpy heat exchangerNoyesNoyesNoyesNoyes
Antifreeze circuityesyesyesyesyesyesyesyes
Summer circuitExhaust air with RLS D1 WRExhaust air with RLS D1 WRExhaust air with RLS D1 WRExhaust air with RLS D1 WRExhaust air with RLS D1 WRExhaust air with RLS D1 WRExhaust air with RLS D1 WRExhaust air with RLS D1 WR
Filter monitoringwith time controlwith time controlwith time controlwith time controlwith time controlwith time controlwith time controlwith time control
Humidity control--------
CO2-control (optional)SKDSKDSKDSKDSKDSKDSKDSKD
Air quality control (optional)EAQ 10/2EAQ 10/2EAQ 10/2EAQ 10/2EAQ 10/2EAQ 10/2EAQ 10/2EAQ 10/2
KNX connection (optional)to be supplied by the customerto be supplied by the customerto be supplied by the customerto be supplied by the customerto be supplied by the customerto be supplied by the customerto be supplied by the customerto be supplied by the customer
MODBUS interfaceNoNoNoNoNoNoNoNo
Control unit included in scope of delivery.RLS 1 WRRLS 1 WRRLS 1 WRRLS 1 WRRLS 1 WRRLS 1 WRRLS 1 WRRLS 1 WR
Control unit (optional)RLS D1 WRRLS D1 WRRLS D1 WRRLS D1 WRRLS D1 WRRLS D1 WRRLS D1 WRRLS D1 WR
Wireless switch on/off (optional)XE 1, XS 1XE 1, XS 1XE 1, XS 1XE 1, XS 1XE 1, XS 1XE 1, XS 1XE 1, XS 1XE 1, XS 1
EnOcean wireless integration (optional)NoNoNoNoNoNoNoNo
Mobile controlNoNoNoNoNoNoNoNo
Housing emission sound pressure level42 dB(A) / 45 dB(A) / 47 dB(A) / Spacing 1m, sound absorption 10 m²42 dB(A) / 45 dB(A) / 47 dB(A) / Spacing 1m, sound absorption 10 m²42 dB(A) / 45 dB(A) / 47 dB(A) / Spacing 1m, sound absorption 10 m²42 dB(A) / 45 dB(A) / 47 dB(A) / Spacing 1m, sound absorption 10 m²32 dB(A) / 34 dB(A) / 35 dB(A) / Spacing 1m, sound absorption 10 m²32 dB(A) / 34 dB(A) / 35 dB(A) / Spacing 1m, sound absorption 10 m²32 dB(A) / 34 dB(A) / 35 dB(A) / Spacing 1m, sound absorption 10 m²32 dB(A) / 34 dB(A) / 35 dB(A) / Spacing 1m, sound absorption 10 m²
Approval numberZ-51.3-292not specifiedZ-51.3-292not specifiedZ-51.3-292not specifiedZ-51.3-292not specified
Packing unit1 piece1 piece1 piece1 piece1 piece1 piece1 piece1 piece
RangeKKKKKKKK
GTIN (EAN)40127999508134012799951100401279995082040127999511174012799950837401279995112440127999508444012799951131
Humidity conditions with enthalpy heat exchanger in accordance with DIN EN 13141-7 (A2)not specified80 %not specified80 %not specified80 %not specified80 %
Power of preheating registernot specifiednot specifiednot specifiednot specified0,74 kW0,74 kW0,74 kW0,74 kW

* Blue markings show the differences between the products.

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Cookies are used on this website, which are necessary for technical reasons, so that we can present users our offers. A cookie that saves your current privacy settings is also used (selection cookie). With the exception of the above-mentioned selection cookie, technically non-essential cookies and tracking mechanisms that enable us to provide you with an optimal user experience as well as customised offers (marketing cookies and tracking mechanisms) are only used if you have previously approved their use by clicking ACCEPT. Details and options for changing your settings at a later date can be found in our cookie settings.

ACCEPT ALL COOKIES Continue with necessary cookies


Acknowledgements | Data protection