WS 320

Centralised ventilation unit with heat recovery in 14 variants, up to 320 m³/h

WS 320 IM0015750.PNG Centralised ventilation unit with heat recovery in 14 variants, up to 320 m³/h

Below you can see a direct comparison of the products you have selected. Differences between the products are highlighted in blue.

Article

WS 320 B

Centralised, highly-efficient ventilation units with EC fans and constant volumetric flow regulation, including bypass and cross-counterflow exchanger, supply and exhaust air on left, air volume 80 - 320 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors or 90° B90-160 elbow needed to connect folded spiral-seams ducts (order as accessories), including RLS 1 WR control unit, including integrated web server and MAICO app (air@home) for mobile unit control, live reports via web tool, DIBT approval and passive house certificate, KNX and EnOcean connection possible

  • On the notes

WS 320 BR

Centralised, highly-efficient ventilation units with EC fans and constant volumetric flow regulation, including cross-counterflow exchanger, supply and exhaust air on right, volumetric flow 80 - 320 m³/h, connection diameter 4 x DN 160, 4 x SVR 160 plug connectors or 90° B90-160 elbow needed to connect folded spiral-seams ducts (order as accessories), including RLS 1 WR control unit, including integrated web server and MAICO app (air@home) for mobile unit control, live reports via web tool, DIBT approval applied for and passive house certificate, KNX and EnOcean connection possible

  • On the notes

WS 320 K

Centralised, highly-efficient ventilation units with EC fans and constant volumetric flow regulation, including preheating register and cross-counterflow exchanger, supply and exhaust air on left, air volume 80 - 320 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors or 90° B90-160 elbow needed to connect folded spiral-seams ducts (order as accessories), including RLS 1 WR control unit, including integrated web server and MAICO app (air@home) for mobile unit control, live reports via web tool, DIBT approval and passive house certificate, KNX and EnOcean connection possible

  • On the notes

WS 320 KR

Centralised, highly-efficient ventilation units with EC fans and constant volumetric flow regulation, including preheating register and cross-counterflow exchanger, supply and exhaust air on right, volumetric flow 80 - 320 m³/h, connection diameter 4 x DN 160, 4 x SVR 160 plug connectors or 90° B90-160 elbow needed to connect folded spiral-seams ducts (order as accessories), including RLS 1 WR control unit, including integrated web server and MAICO app (air@home) for mobile unit control, live reports via web tool, DIBT approval applied for and passive house certificate, KNX and EnOcean connection possible

  • On the notes

WS 320 KB

Centralised, highly-efficient ventilation units with EC fans and constant volumetric flow regulation, including preheating register, bypass and cross-counterflow exchanger, supply and exhaust air on left, air volume 80 - 320 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors or 90° B90-160 elbow needed to connect folded spiral-seams ducts (order as accessories), including RLS 1 WR control unit, including integrated web server and MAICO app (air@home) for mobile unit control, live reports via web tool, DIBT approval and passive house certificate, KNX and EnOcean connection possible

  • On the notes

WS 320 KBR

Centralised, highly-efficient ventilation units with EC fans and constant volumetric flow regulation, including preheating register, bypass and cross-counterflow exchanger, supply and exhaust air on right, volumetric flow 80 - 320 m³/h, connection diameter 4 x DN 160, 4 x SVR 160 plug connectors or 90° B90-160 elbow needed to connect folded spiral-seams ducts (order as accessories), including RLS 1 WR control unit, including integrated web server and MAICO app (air@home) for mobile unit control, live reports via web tool, DIBT approval applied for and passive house certificate, KNX and EnOcean connection possible

  • On the notes

WS 320 ET

Centralised, highly-efficient ventilation units with EC fans and constant volumetric flow regulation, including enthalpy cross-counterflow exchanger, supply and exhaust air on left, air volume 80 - 320 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors or 90° B90-160 elbow needed to connect folded spiral-seams ducts (order as accessories), including RLS 1 WR control unit, including integrated web server and MAICO app (air@home) for mobile unit control, live reports via web tool, DIBT approval and passive house certificate, KNX and EnOcean connection possible

  • On the notes

WS 320 RET

Centralised, highly-efficient ventilation units with EC fans and constant volumetric flow regulation, including enthalpy cross-counterflow exchanger, supply and exhaust air on right, volumetric flow 80 - 320 m³/h, connection diameter 4 x DN 160, 4 x SVR 160 plug connectors or 90° B90-160 elbow needed to connect folded spiral-seams ducts (order as accessories), including RLS 1 WR control unit, including integrated web server and MAICO app (air@home) for mobile unit control, live reports via web tool, DIBT approval applied for and passive house certificate, KNX and EnOcean connection possible

  • On the notes

WS 320 BET

Centralised, highly-efficient ventilation units with EC fans and constant volumetric flow regulation, including bypass and enthalpy cross-counterflow exchanger, supply and exhaust air on left, air volume 80 - 320 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors or 90° B90-160 elbow needed to connect folded spiral-seams ducts (order as accessories), including RLS 1 WR control unit, including integrated web server and MAICO app (air@home) for mobile unit control, live reports via web tool, DIBT approval and passive house certificate, KNX and EnOcean connection possible

  • On the notes

WS 320 BRET

Centralised, highly-efficient ventilation units with EC fans and constant volumetric flow regulation, including bypass and enthalpy cross-counterflow exchanger, supply and exhaust air on right, volumetric flow 80 - 320 m³/h, connection diameter 4 x DN 160, 4 x SVR 160 plug connectors or 90° B90-160 elbow needed to connect folded spiral-seams ducts (order as accessories), including RLS 1 WR control unit, including integrated web server and MAICO app (air@home) for mobile unit control, live reports via web tool, DIBT approval applied for and passive house certificate, KNX and EnOcean connection possible

  • On the notes

WS 320 KET

Centralised, highly-efficient ventilation units with EC fans and constant volumetric flow regulation, including preheating register and enthalpy cross-counterflow exchanger, supply and exhaust air on left, air volume 80 - 320 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors or 90° B90-160 elbow needed to connect folded spiral-seams ducts (order as accessories), including RLS 1 WR control unit, including integrated web server and MAICO app (air@home) for mobile unit control, live reports via web tool, DIBT approval and passive house certificate, KNX and EnOcean connection possible

  • On the notes

WS 320 KRET

Centralised, highly-efficient ventilation units with EC fans and constant volumetric flow regulation, including preheating register and enthalpy cross-counterflow exchanger, supply and exhaust air on right, air volume 80 - 320 m³/h, connection diameter 4 x DN 160, 4 x SVR 160 plug connectors or 90° B90-160 elbow needed to connect folded spiral-seams ducts (order as accessories), including RLS 1 WR control unit, including integrated web server and MAICO app (air@home) for mobile unit control, live reports via web tool, DIBT approval applied for and passive house certificate, KNX and EnOcean connection possible

  • On the notes

WS 320 KBET

Centralised, highly-efficient ventilation units with EC fans and constant volumetric flow regulation, including preheating register, bypass and enthalpy cross-counterflow exchanger, supply and exhaust air on left, air volume 80 - 320 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors or 90° B90-160 elbow needed to connect folded spiral-seams ducts (order as accessories), including RLS 1 WR control unit, including integrated web server and MAICO app (air@home) for mobile unit control, live reports via web tool, DIBT approval and passive house certificate, KNX and EnOcean connection possible

  • On the notes

WS 320 KBRET

Centralised, highly-efficient ventilation units with EC fans and constant volumetric flow regulation, including preheating register, bypass and enthalpy cross-counterflow exchanger, supply and exhaust air on right, air volume 80 - 320 m³/h, connection diameter 4 x DN 160, 4 x SVR 160 plug connectors or 90° B90-160 elbow needed to connect folded spiral-seams ducts (order as accessories), including RLS 1 WR control unit, including integrated web server and MAICO app (air@home) for mobile unit control, live reports via web tool, DIBT approval applied for and passive house certificate, KNX and EnOcean connection possible

  • On the notes
ArticleWS 320 BWS 320 BRWS 320 KWS 320 KRWS 320 KBWS 320 KBRWS 320 ETWS 320 RETWS 320 BETWS 320 BRETWS 320 KETWS 320 KRETWS 320 KBETWS 320 KBRET
Product detailsProduct detailsProduct detailsProduct detailsProduct detailsProduct detailsProduct detailsProduct detailsProduct detailsProduct detailsProduct detailsProduct detailsProduct detailsProduct details
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
Product type Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit Centralised ventilation unit
Article number: 0095.0221 0095.0262 0095.0222 0095.0263 0095.0223 0095.0264 0095.0224 0095.0265 0095.0225 0095.0266 0095.0226 0095.0267 0095.0227 0095.0268
Air flow volume

80 m³/h - 320 m³/h

80 m³/h - 320 m³/h

80 m³/h - 320 m³/h

80 m³/h - 320 m³/h

80 m³/h - 320 m³/h

80 m³/h - 320 m³/h

80 m³/h - 320 m³/h

80 m³/h - 320 m³/h

80 m³/h - 320 m³/h

80 m³/h - 320 m³/h

80 m³/h - 320 m³/h

80 m³/h - 320 m³/h

80 m³/h - 320 m³/h

80 m³/h - 320 m³/h

SEC average

-42,5 kWh/(m²*a)

-42,5 kWh/(m²*a)

-42,5 kWh/(m²*a)

-42,5 kWh/(m²*a)

-42,5 kWh/(m²*a)

-42,5 kWh/(m²*a)

-40 kWh/(m²*a)

-40 kWh/(m²*a)

-40 kWh/(m²*a)

-40 kWh/(m²*a)

-40 kWh/(m²*a)

-40 kWh/(m²*a)

-40 kWh/(m²*a)

-40 kWh/(m²*a)

Energy efficiency class

A+

A+

A+

A+

A+

A+

A

A

A

A

A

A

A

A

Type of voltage

Alternating current

Alternating current

Alternating current

Alternating current

Alternating current

Alternating current

Alternating current

Alternating current

Alternating current

Alternating current

Alternating current

Alternating current

Alternating current

Alternating current

Rated voltage

230 V

230 V

230 V

230 V

230 V

230 V

230 V

230 V

230 V

230 V

230 V

230 V

230 V

230 V

Frequency

50 Hz/60 Hz

50 Hz/60 Hz

50 Hz/60 Hz

50 Hz/60 Hz

50 Hz/60 Hz

50 Hz/60 Hz

50 Hz/60 Hz

50 Hz/60 Hz

50 Hz/60 Hz

50 Hz/60 Hz

50 Hz/60 Hz

50 Hz/60 Hz

50 Hz/60 Hz

50 Hz/60 Hz

Power consumption in accordance with DIN EN 13141-7 (A7)

37 W

37 W

37 W

37 W

37 W

37 W

36 W

36 W

36 W

36 W

36 W

36 W

36 W

36 W

Stand-by power consumption

< 1 W

< 1 W

< 1 W

< 1 W

< 1 W

< 1 W

< 1 W

< 1 W

< 1 W

< 1 W

< 1 W

< 1 W

< 1 W

< 1 W

Imax

1,5 A

1,5 A

11 A

11 A

11 A

11 A

1,5 A

1,5 A

1,5 A

1,5 A

11 A

11 A

11 A

11 A

Degree of protection

IP 40

IP 40

IP 40

IP 40

IP 40

IP 40

IP 40

IP 40

IP 40

IP 40

IP 40

IP 40

IP 40

IP 40

DIBT approval

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

PHI certification

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

SPI value

0,18 Wh/m³

0,18 Wh/m³

0,18 Wh/m³

0,18 Wh/m³

0,18 Wh/m³

0,18 Wh/m³

0,18 Wh/m³

0,18 Wh/m³

0,18 Wh/m³

0,18 Wh/m³

0,18 Wh/m³

0,18 Wh/m³

0,18 Wh/m³

0,18 Wh/m³

Installation site

floor / wall

floor / wall

floor / wall

floor / wall

floor / wall

floor / wall

floor / wall

floor / wall

floor / wall

floor / wall

floor / wall

floor / wall

floor / wall

floor / wall

System type

Centralised

Centralised

Centralised

Centralised

Centralised

Centralised

Centralised

Centralised

Centralised

Centralised

Centralised

Centralised

Centralised

Centralised

Housing material

Galvanised sheet steel, powder coated

Galvanised sheet steel, powder coated

Galvanised sheet steel, powder coated

Galvanised sheet steel, powder coated

Galvanised sheet steel, powder coated

Galvanised sheet steel, powder coated

Galvanised sheet steel, powder coated

Galvanised sheet steel, powder coated

Galvanised sheet steel, powder coated

Galvanised sheet steel, powder coated

Galvanised sheet steel, powder coated

Galvanised sheet steel, powder coated

Galvanised sheet steel, powder coated

Galvanised sheet steel, powder coated

Heat exchanger material

Synthetic material

Synthetic material

Synthetic material

Synthetic material

Synthetic material

Synthetic material

Synthetic material

Synthetic material

Synthetic material

Synthetic material

Synthetic material

Synthetic material

Synthetic material

Synthetic material

Inner coating material

Plastic EPP

Plastic EPP

Plastic EPP

Plastic EPP

Plastic EPP

Plastic EPP

Plastic EPP

Plastic EPP

Plastic EPP

Plastic EPP

Plastic EPP

Plastic EPP

Plastic EPP

Plastic EPP

Colour

Traffic white (RAL 9016)

Traffic white (RAL 9016)

Traffic white (RAL 9016)

Traffic white (RAL 9016)

Traffic white (RAL 9016)

Traffic white (RAL 9016)

Traffic white (RAL 9016)

Traffic white (RAL 9016)

Traffic white (RAL 9016)

Traffic white (RAL 9016)

Traffic white (RAL 9016)

Traffic white (RAL 9016)

Traffic white (RAL 9016)

Traffic white (RAL 9016)

Weight

67 kg

67 kg

67 kg

67 kg

67 kg

67 kg

69,61 kg

69,61 kg

69,61 kg

69,61 kg

69,61 kg

69,61 kg

69,61 kg

69,61 kg

Weight including packaging

79,19 kg

79,29 kg

79,19 kg

79,19 kg

79,19 kg

79,19 kg

81,8 kg

81,8 kg

81,8 kg

81,8 kg

81,8 kg

81,8 kg

81,8 kg

81,8 kg

Filter class

ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)

ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)

ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)

ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)

ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)

ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)

ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)

ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)

ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)

ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)

ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)

ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)

ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)

ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)

Connection diameter

160 mm

160 mm

160 mm

160 mm

160 mm

160 mm

160 mm

160 mm

160 mm

160 mm

160 mm

160 mm

160 mm

160 mm

Connection diameter of condensation drain

1 1/2" (screen valve)

1 1/2" (screen valve)

1 1/2" (screen valve)

1 1/2" (screen valve)

1 1/2" (screen valve)

1 1/2" (screen valve)

1 1/2" (screen valve)

1 1/2" (screen valve)

1 1/2" (screen valve)

1 1/2" (screen valve)

1 1/2" (screen valve)

1 1/2" (screen valve)

1 1/2" (screen valve)

1 1/2" (screen valve)

Width

841 mm

841 mm

841 mm

841 mm

841 mm

841 mm

841 mm

841 mm

841 mm

841 mm

841 mm

841 mm

841 mm

841 mm

Height

857 mm

857 mm

857 mm

857 mm

857 mm

857 mm

857 mm

857 mm

857 mm

857 mm

857 mm

857 mm

857 mm

857 mm

Depth

598 mm

598 mm

598 mm

598 mm

598 mm

598 mm

598 mm

598 mm

598 mm

598 mm

598 mm

598 mm

598 mm

598 mm

Width with packaging

900 mm

900 mm

900 mm

900 mm

900 mm

900 mm

900 mm

900 mm

900 mm

900 mm

900 mm

900 mm

900 mm

900 mm

Height with packaging

1.120 mm

1.120 mm

1.120 mm

1.120 mm

1.120 mm

1.120 mm

1.120 mm

1.120 mm

1.120 mm

1.120 mm

1.120 mm

1.120 mm

1.120 mm

1.120 mm

Depth with packaging

650 mm

650 mm

650 mm

650 mm

650 mm

650 mm

650 mm

650 mm

650 mm

650 mm

650 mm

650 mm

650 mm

650 mm

Airstream temperature at IMax

-20 °C up to 40 °C

-20 °C up to 40 °C

-20 °C up to 40 °C

-20 °C up to 40 °C

-20 °C up to 40 °C

-20 °C up to 40 °C

-20 °C up to 40 °C

-20 °C up to 40 °C

-20 °C up to 40 °C

-20 °C up to 40 °C

-20 °C up to 40 °C

-20 °C up to 40 °C

-20 °C up to 40 °C

-20 °C up to 40 °C

Max. degree of heat provision in accordance with DIN EN 13141-7 (A7)

96 %

96 %

96 %

96 %

96 %

96 %

93 %

93 %

93 %

93 %

93 %

93 %

93 %

93 %

Heat exchanger construction type

Cross-counterflow

Cross-counterflow

Cross-counterflow

Cross-counterflow

Cross-counterflow

Cross-counterflow

Enthalpy cross-counterflow

Enthalpy cross-counterflow

Enthalpy cross-counterflow

Enthalpy cross-counterflow

Enthalpy cross-counterflow

Enthalpy cross-counterflow

Enthalpy cross-counterflow

Enthalpy cross-counterflow

Position – exhaust air

left

right

left

right

left

right

left

right

left

right

left

right

left

right

Bypass

yes

yes

No

No

yes

yes

No

No

yes

yes

No

No

yes

yes

Frost protection

No

No

integrated

integrated

integrated

integrated

No

No

No

No

integrated

integrated

integrated

integrated

Enthalpy heat exchanger

No

No

No

No

No

No

yes

yes

yes

yes

yes

yes

yes

yes

Antifreeze circuit

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

Summer circuit

ECO exhaust air / ECO supply air

ECO exhaust air / ECO supply air

ECO exhaust air / ECO supply air

ECO exhaust air / ECO supply air

ECO exhaust air / ECO supply air

ECO exhaust air / ECO supply air

ECO exhaust air / ECO supply air

ECO exhaust air / ECO supply air

ECO exhaust air / ECO supply air

ECO exhaust air / ECO supply air

ECO exhaust air / ECO supply air

ECO exhaust air / ECO supply air

ECO exhaust air / ECO supply air

ECO exhaust air / ECO supply air

Filter monitoring

with time control

with time control

with time control

with time control

with time control

with time control

with time control

with time control

with time control

with time control

with time control

with time control

with time control

with time control

Humidity control

integrated

integrated

integrated

integrated

integrated

integrated

integrated

integrated

integrated

integrated

integrated

integrated

integrated

integrated

CO2 regulation

SKD

SKD

SKD

SKD

SKD

SKD

SKD

SKD

SKD

SKD

SKD

SKD

SKD

SKD

Air quality control (optional)

EAQ 10/3

EAQ 10/3

EAQ 10/3

EAQ 10/3

EAQ 10/3

EAQ 10/3

EAQ 10/3

EAQ 10/3

EAQ 10/3

EAQ 10/3

EAQ 10/3

EAQ 10/3

EAQ 10/3

EAQ 10/3

KNX connection (optional)

K-SM

K-SM

K-SM

K-SM

K-SM

K-SM

K-SM

K-SM

K-SM

K-SM

K-SM

K-SM

K-SM

K-SM

MODBUS interface

integrated

integrated

integrated

integrated

integrated

integrated

integrated

integrated

integrated

integrated

integrated

integrated

integrated

integrated

Control unit included in scope of delivery.

RLS 1 WR, App

RLS 1 WR, App

RLS 1 WR, App

RLS 1 WR, App

RLS 1 WR, App

RLS 1 WR, App

RLS 1 WR, App

RLS 1 WR, App

RLS 1 WR, App

RLS 1 WR, App

RLS 1 WR, App

RLS 1 WR, App

RLS 1 WR, App

RLS 1 WR, App

Control unit (optional)

RLS T2 WS, RLS G1 WS

RLS T2 WS, RLS G1 WS

RLS T2 WS, RLS G1 WS

RLS T2 WS, RLS G1 WS

RLS T2 WS, RLS G1 WS

RLS T2 WS, RLS G1 WS

RLS T2 WS, RLS G1 WS

RLS T2 WS, RLS G1 WS

RLS T2 WS, RLS G1 WS

RLS T2 WS, RLS G1 WS

RLS T2 WS, RLS G1 WS

RLS T2 WS, RLS G1 WS

RLS T2 WS, RLS G1 WS

RLS T2 WS, RLS G1 WS

EnOcean wireless integration (optional)

E-SM

E-SM

E-SM

E-SM

E-SM

E-SM

E-SM

E-SM

E-SM

E-SM

E-SM

E-SM

E-SM

E-SM

Mobile control

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

Housing emission sound pressure level

36 dB(A) / Spacing 1m, sound absorption 10 m²

36 dB(A) / Spacing 1m, sound absorption 10 m²

36 dB(A) / Spacing 1m, sound absorption 10 m²

36 dB(A) / Spacing 1m, sound absorption 10 m²

36 dB(A) / Spacing 1m, sound absorption 10 m²

36 dB(A) / Spacing 1m, sound absorption 10 m²

36 dB(A) / Spacing 1m, sound absorption 10 m²

36 dB(A) / Spacing 1m, sound absorption 10 m²

36 dB(A) / Spacing 1m, sound absorption 10 m²

36 dB(A) / Spacing 1m, sound absorption 10 m²

36 dB(A) / Spacing 1m, sound absorption 10 m²

36 dB(A) / Spacing 1m, sound absorption 10 m²

36 dB(A) / Spacing 1m, sound absorption 10 m²

36 dB(A) / Spacing 1m, sound absorption 10 m²

Packing unit

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

Range

K

K

K

K

K

K

K

K

K

K

K

K

K

K

GTIN (EAN)

4012799952213

4012799952626

4012799952220

4012799952633

4012799952237

4012799952640

4012799952244

4012799952657

4012799952251

4012799952664

4012799952268

4012799952671

4012799952275

4012799952688

Power of preheating register

not specified

not specified

1,8 kW

1,8 kW

1,8 kW

1,8 kW

not specified

not specified

not specified

not specified

1,8 kW

1,8 kW

1,8 kW

1,8 kW

Humidity recovery with enthalpy heat exchanger in accordance with DIN EN 13141-7 (A2)

not specified

not specified

not specified

not specified

not specified

not specified

68 %

68 %

68 %

68 %

68 %

68 %

68 %

68 %

* Blue markings show the differences between the products.

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings