Small room fan

AKE 100

Article number: 0084.0220
Manufacturer: MAICO
Automatic cellar dehumidification, DN 100, air volume 92 m³/h
Application examples: Cellar and/or cellar room, Utility room, Drying room, Utility room
AKE 100 IM0017002.PNG Automatic cellar dehumidification, DN 100, air volume 92 m³/h
AKE 100 IM0013704.PNG Automatic cellar dehumidification, DN 100, air volume 92 m³/h

Characteristic curve

AKE 100 - Characteristic curve

  • AKE 100 IM0017004.PNG Automatic cellar dehumidification, DN 100, air volume 92 m³/h

Dimensioned drawing

AKE 100 - Dimensioned drawing [mm]

  • AKE 100 IM0019025.PNG Automatic cellar dehumidification, DN 100, air volume 92 m³/h
  1. Cable entry

AKE 100 - Dimensioned drawing [mm]

  • AKE 100 IM0017001.PNG Automatic cellar dehumidification, DN 100, air volume 92 m³/h

Technical data

AKE 100 - Technical data

Article AKE 100
Air flow volume 92 m³/h
Rotating speed 2.500 1/min
Speed controllable
Reversing capacity
SEC average -24,18 kWh/(m²*a)
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Nominal output 8 W
Stand-by power consumption 2 W
Imax 0,06 A
Degree of protection IP X4
Mains cable 5 x 1,5 mm²
Installation site Wall
Type of installation Surface-mounted
Installation position any
Material Synthetic material
Colour Traffic white, similar to RAL 9016
Weight 0,804 kg
Shutter none
Nominal size 100 mm
Cable length 1 m
Width 159 mm
Height 159 mm
Depth 130 mm
Wall thickness max. 0.85 m (if a 1m length of cable isn't sufficient, please also order the 6m sensor cable)
Airstream temperature at IMax 40 °C
Sound pressure level 32 dB(A) / Distance 3 m, Free-field conditions
Packing unit 1 piece
Range A
GTIN (EAN) 4012799842200
Article number 0084.0220

Accessories / Spare parts

Product description

Productdescription

AKE 100

short description

Automatic cellar dehumidification, DN 100, air volume 92 m³/h

Product description

Features

  • Intelligently programmed automatic cellar dehumidification for the highest demands.
  • Integrated automatic humidity control.
  • Designer cover conceals the inlet.
  • Barrier-free product as the fan switches itself on and off automatically without additional switches.
  • Fan monitors the room humidity.
  • Frost protection function: Switch off the system at inside temperatures below 5 °C.
  • System can be switched off manually using a button or switch.
  • Additional installation of switch for unit not needed.
  • Can also be switched with separate button or switch as an option.
  • Status and function displayed using LEDs.
  • Scope of delivery:
    • Fan
    • External shutter
    • Sensors
    • 1m connection cable
  • Not speed-controllable.
  • For dehumidification.
  • IP X4 degree of protection.
  • Protection class II.
  • Colour: traffic white, similar to RAL 9016.
  • Housing made of impact resistant plastic material.
  • Thermal overload protection.

Frost protection

  • To prevent the room from cooling down, the AKE has a frost protection function. This means that the fan automatically switches off at inside temperatures of less than 5 °C.

Protection against insufficient humidity

  • To prevent the room from drying out, the AKE has a dry protection function. This means that the fan automatically switches off at a relative room humidity of less than 30 %.

Motor

  • Energy-saving robust motor with ball bearings, maintenance-free.
  • Suitable for continuous operation.

Mounting instructions

  • Simple installation
    • AKE 100: Core drill hole 105 mm / 120 mm when installing with WH 100 wall sleeve accessory.
    • AKE 150: Core drill hole 155 mm / 170 mm when installing with WH 150 wall sleeve.
  • Wall and ceiling installation is possible

Electrical connection

  • Electrical connection can be either surface- or recessed-mounted.
  • Surface installation for AKE 100 with ECA-DR spacing frame accessory.

Table of contents

Wiring diagram

AKE 100 - Wiring diagram

EF - dehumidification control

T1 - Optional button for manual operation

Z - Connection for optional supply air element, e.g. ECA 11 E



Ab - Fuse protection provided by customer

mE - Manual switching-on option

S - Controller

AL - Exhaust air

ZL - Supply air option



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Cookies are used on this website, which are necessary for technical reasons, so that we can present users our offers. A cookie that saves your current privacy settings is also used (selection cookie). With the exception of the above-mentioned selection cookie, technically non-essential cookies and tracking mechanisms that enable us to provide you with an optimal user experience as well as customised offers (marketing cookies and tracking mechanisms) are only used if you have previously approved their use by clicking ACCEPT. Details and options for changing your settings at a later date can be found in our cookie settings.

ACCEPT ALL COOKIES Continue with necessary cookies


Acknowledgements | Data protection