Axial wall-mounted fan

ENR 20

Article number: 0081.0316
Manufacturer: MAICO
Axial wall-mounted fan for ventilation and air extraction, DN 200
Application examples: Office, Office, Commercial premises, Restaurant, Production facility
Product data sheet
ENR 20 IM0014159.PNG Axial wall-mounted fan for ventilation and air extraction, DN 200

Characteristic curve

ENR 20 - Characteristic curve

Dimensioned drawing

ENR 20 - Dimensioned drawing [mm]

  1. Inside

Technical data

ENR 20 - Technical data

Article ENR 20
Air flow volume 460 m³/h
Rotating speed 1.380 1/min
Impeller type axial
Air direction Ventilation or air extraction
Speed controllable
Reversing capacity
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Nominal output 42 W
Inom 0,15 A
Imax 0,21 A
Degree of protection IP 44
Mains cable 5 x 1,5 mm²
Installation site Wall / Ceiling
Type of installation Surface-mounted
Installation position any
Material Synthetic material
Colour Traffic white, similar to RAL 9016
Weight 2,7 kg
Weight including packaging 3,26 kg
Nominal size 200 mm
Width 320 mm
Height 320 mm
Depth 158 mm
Width with packaging 355 mm
Height with packaging 355 mm
Depth with packaging 185 mm
Airstream temperature at IMax 40 °C
Sound pressure level 48 dB(A)
Packing unit 1 piece
Range C
GTIN (EAN) 4012799813163
Article number 0081.0316

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA7, high (dB(A))

57

LWA7= housing and free inlet sound power level in dB.

Accessories / Accessories of

ENR 20 - Accessories / Accessories of

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Dark room attachment ZDK 25 0093.0350 on request
  • On the notes

General accessories

is a general accessory of

Product type Name Art. No. Price*(EUR) Action
Shutter, electric BK 20 0093.0900 on request
  • On the notes

Product description

Productdescription

ENR 20

short description

Axial wall-mounted fan for ventilation and air extraction, DN 200

Product description

Features

  • Housing can be easily removed without tools, for cleaning.
  • Pleasantly quiet.
  • Clean and fast exchange of existing EN devices thanks to 100 % compatibility with the previous EN and ET devices.
  • In the case of existing electrical external shutters with plug connection: Remove the plug and reconnect the individual cables according to the EN/ENR wiring diagrams.
  • Maintenance-free fan.

Motor

  • Thermal overload protection as standard feature.
  • Robust motor.
  • Suitable for continuous operation.

Electrical connection

  • Electrical connection can be either surface- or recessed-mounted.

Safety instructions

  • The fan may be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN ISO 13857.

Table of contents

Wiring diagram

ENR 20 - Wiring diagram

ENR 20, ENR 25, ENR 31 with on/off switch and three-position switch

S1 - On / Off

S2 - Switching between air extraction and ventilation

Terminal 5 - Air extraction

Terminal 6 - Ventilation

* - duct only for MK... shutter



ENR 20, ENR 25, ENR 31 with FS 6, FS 7 reversing switch

FS 6 - Step switch for (2-speed, air extraction or ventilation)

FS 7 - Reversing switch (air extraction or ventilation)

* - duct only for MK... shutter



ENR 20, ENR 25, ENR 31 with W 1, WU 1 reversing switch

W 1 - Reversing switch (air extraction or ventilation), surface-mounted

WU 1 - Reversing switch (air extraction or ventilation), recessed-mounted

* - duct only for MK... shutter



ENR 20, ENR 25, ENR 31 with TRE 5-step switch and W 1, WU 1 reversing switch

TRE - 5-step transformer (on/off, 5-speed)

W 1 - Reversing switch (air extraction or ventilation), surface-mounted

WU 1 - Reversing switch (air extraction or ventilation), recessed-mounted

* - duct only for MK... shutter



ENR 20, ENR 25, ENR 31 with TRE 5-step transformer and three-position switch

TRE - 5-step transformer (on/off, 5-speed)

S1 - Reversing switch (air extraction or ventilation)

* - duct only for MK... shutter



ENR 20, ENR 25, ENR 31 with TRE..S 5-step transformer and ESS 20 5-step switch.

TRE - 5-step transformer, control cabinet installation

ESS 20 - 5-step switch (on/off, 5-speed)

S1 - Reversing switch (air extraction or ventilation)

* - duct only for MK... shutter



Predecessor - successor

ENR 20 - Predecessor

Product type Name Art. No. Action
Wall-mounted fan ENR 20 No longer available for delivery 0081.0304
  • On the notes
Wall-mounted fan ETR 20 No longer available for delivery 0081.0504
  • On the notes

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings