Axial wall fan

EZQ 50/6 B

Article number: 0083.0113
Manufacturer: MAICO
Axial wall fan with square wall plate, DN 500, single-phase AC
Application examples: Production facility, Commercial premises, Garage, Building container, Storage facility
EZQ 50/6 B IM0009977.PNG Axial wall fan with square wall plate, DN 500, single-phase AC

Characteristic curve

EZQ 50/6 B - Characteristic curve

Dimensioned drawing

EZQ 50/6 B - Dimensioned drawing [mm]

  1. Steel wall plate = EZQ/DZQ model
  2. Steel wall ring = EZS/DZS model

Technical data

EZQ 50/6 B - Technical data

Article EZQ 50/6 B
Model Square wall plate
Air flow volume 5.860 m³/h
Air volumenom 4.240 m³/h / in opt. efficiency
Pressure pfs, nom 62 Pa / in opt. efficiency
Rotating speed nnom 955 1/min / in opt. efficiency
Rotating speed 972 1/min
Impeller type axial
Speed controllable
Reversing capacity
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Nominal output 240 W / in opt. efficiency
Inom 1,1 A / in opt. efficiency
Imax 1,6 A
Degree of protection IP 55
Insulation class B
Installation site Wall / Ceiling
Type of installation Surface-mounted
Installation position horizontal / vertical
Material Sheet steel, galvanised
Weight 17,7 kg
Nominal size 500 mm
Width 700 mm
Height 700 mm
Depth 329 mm
Airstream temperature at nominal current -20 °C up to 50 °C
Airstream temperature at IMax -20 °C up to 50 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799831136
Article number 0083.0113
Article EZQ 50/6 B
Total efficiency η 30,4 %
Measurement category A
Efficiency category static
Efficiency level N 40,7
VSD necessary No
Year of manufacture see rating plate
Manufacturer’s name / official registration number / manufacturer's place of establishment Maico Elektroapparate-Fabrik GmbH / Freiburg registration court, HRB 601233 / Villingen-Schwenningen
Art. No. 0083.0113
PBEP / Air volumeBEP / Pfs, BEP 0,24 kW / 4.240 m³/h / 62 Pa
nBEP 955 1/min
Specific ratio ≈ 1
Information about dismantling and disposal see mounting instructions
Information about installation, operation and repairs see mounting instructions
Objects used to measure efficiency which are not described by the measurement category -
Sound power levelLWA7 72 dB(A)

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA7, S1 (dB(A))

26

37

35

39

43

38

25

14

46

LWA7, S2 (dB(A))

38

43

45

51

56

54

45

32

59

LWA7, S3 (dB(A))

34

54

56

60

66

66

59

49

70

LWA7, S4 (dB(A))

34

53

57

62

67

68

61

51

72

LWA7, S5 (dB(A))

35

55

58

63

68

68

62

52

72

LWA8, S1 (dB(A))

29

35

37

48

42

37

25

14

50

LWA8, S2 (dB(A))

41

45

48

52

64

64

66

64

71

LWA8, S3 (dB(A))

51

58

60

63

70

71

72

69

77

LWA8, S4 (dB(A))

50

58

60

64

70

71

72

69

77

LWA8, S5 (dB(A))

51

60

61

65

71

72

73

70

78

LWA7= housing and free inlet sound power level in dB.

LWA8= housing and free outlet sound power level in dB.

Accessories

EZQ 50/6 B - Accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
Shutter AS 50 0151.0336 on request
  • On the notes
Connection frame ZVR 50 0093.0197 on request
  • On the notes
Shutter, manual RS 50 0151.0344 on request
  • On the notes
Servomotor MS 2 0093.0403 on request
  • On the notes
External grille MLA 50 0151.0116 on request
  • On the notes
External grille MLZ 50 0151.0106 on request
  • On the notes
Extension sleeve VH 50 0055.0035 on request
  • On the notes
Internal grille IG 45/50 0059.0176 on request
  • On the notes
Main switch, service switch HS 3 0157.0736 on request
  • On the notes
Rotary switch DS 10 0157.0410 on request
  • On the notes
Reversing switch W 1 0157.0101 on request
  • On the notes
Reversing switch WU 1 0157.0102 on request
  • On the notes
Reversing switch FS 7 0016.0107 on request
  • On the notes
Contactor US 16 T 0157.0769 on request
  • On the notes
Speed controller STX 2,5 New development 0157.1562 on request
  • On the notes
Speed controller, distribution board STSX 2,5 New development 0157.1564 on request
  • On the notes
Speed controller STU 2,5 No longer available for delivery 0157.0815 on request
  • On the notes
Reversing switch UWK 1 0157.0817 on request
  • On the notes
Speed controller, distribution board STS 2,5 No longer available for delivery 0157.0255 on request
  • On the notes
5-step transformer TRE 1,6-2 0157.0158 on request
  • On the notes
5-step transformer, control cabinet TRE 1,6 S-2 0157.0162 on request
  • On the notes
5-step switch for TRE...S -2/ TR...S-2 5-step transformers ESS 20 0157.0749 on request
  • On the notes
Thermostat THR 10 0157.0774 on request
  • On the notes
Thermostat TH 10 0157.0764 on request
  • On the notes
Thermostat TH 16 0157.0748 on request
  • On the notes
Temperature control system EAT 6 G/1 0157.0808 on request
  • On the notes
Temperature control system EAT 6 TG 0157.0755 on request
  • On the notes
Hygrostat HY 230 0157.0126 on request
  • On the notes
Hygrostat HY 230 I 0157.0127 on request
  • On the notes
Hygrostat HY 10 AP Discontinued product 0157.0358 on request
  • On the notes
Hygrostat HY 10 UP Discontinued product 0157.0357 on request
  • On the notes
Air quality controller EAQ 10/1 0157.0777 on request
  • On the notes
Speed controller ST 2,5 No longer available for delivery 0157.0811 on request
  • On the notes
Speed controller, reversing switch STW 2,5 No longer available for delivery 0016.0142 on request
  • On the notes
Temperature control system, power module EALT 6 No longer available for delivery 0157.0756 on request
  • On the notes

Product description

Productdescription

EZQ 50/6 B

short description

Axial wall fan with square wall plate, DN 500, single-phase AC

Product description

Features

  • Yellow chromated protective grille on the intake side, potection against accidental contact in accordance with DIN EN ISO 13857.
  • 8-blade impellers made of glass-fibre filled polyamide. Dynamically balanced at two levels, in accordance with performance level 6.3, DIN ISO 1940, Part 1.
  • Can be fitted in any position.

Air flow direction

  • The following illustration shows the air flow direction:
  1. Air flow direction A: With air drawn across the motor, standard
  2. Air flow direction B: With air blown across the motor, available on request
  3. Rotational direction
  4. Reversing mode: The volumetric flow is reduced by approx. 35 % with abnormal air flow direction.

Motor

  • Asynchronous motor.
  • Speed controllable. Exception: Type EZQ 45/6 B, EZS 45/6 B, DZQ 40/2 B and DZS 40/2 B.
  • Reversible. Exception: Fans with shaded-pole motors (...-E).
  • Not suitable for ventilating steam-saturated air.

AC motor

  • EZQ and EZS model series.
  • Rated voltage 230 V, 50 Hz.
  • Thermal overload protection as a standard feature.
  • "../B" fans: Capacitor motors with operating capacitor fitted to protective grille or to wall sleeve, IP 55 degree of protection.
  • "../D" fans: Capacitor motors with operating capacitor in terminal box, IP 54 degree of protection.
  • "../E" fans: Shaded-pole motors, non reversible, IP 54 degree of protection.

Electrical connection

  • To terminal block under the motor cover.

Safety instructions

  • The fan may be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN ISO 13857.

Special versions

  • The following special versions are available at extra cost on request:
    • Special voltages and frequencies.
    • Single-phase motors with thermal contacts or PTC thermistor, with potential-free terminal connections.
    • Condensation drainage holes.
    • Fans with enhanced anti-corrosion protection.
    • Impellers made of aluminium.
  • Information on operation at temperatures occasionally below -20°C available upon request.
  • If operating with frequency converters, the factory must be consulted.
  • Feasibility must be checked in each case.

Table of contents

Wiring diagram

EZQ 50/6 B - Wiring diagram



















Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. OK

Acknowledgements Data protection