Axial duct fan

DZR 60/84 B

Article number: 0086.0055
Manufacturer: MAICO
Axial duct fan, DN 600, three-phase AC, pole-changeable
Application examples: Machine extraction unit, Showroom, Foreman's office, Workshop, Production site
DZR 60/84 B IM0009987.PNG Axial duct fan, DN 600, three-phase AC, pole-changeable

Characteristic curve

DZR 60/84 B - Characteristic curve

Dimensioned drawing

DZR 60/84 B - Dimensioned drawing [mm]

Number of flange holes: 16

Technical data

DZR 60/84 B - Technical data

Article DZR 60/84 B
Air flow volume 7.650 m³/h / 15.310 m³/h
Air volumenom 5.660 m³/h / 11.490 m³/h / in opt. efficiency
Pressure pfs, nom 47 Pa - 195 Pa / in opt. efficiency
Rotating speed nnom 700 1/min - 1.430 1/min / in opt. efficiency
Rotating speed 726 1/min / 1.459 1/min
Impeller type axial
Speed controllable
Reversing capacity
Type of voltage Three-phase AC
Rated voltage 400 V
Frequency 50 Hz
Nominal output 280 W / 1.630 W / in opt. efficiency
Inom 1 A / 3,1 A / in opt. efficiency
Imax 3,9 A
Degree of protection IP 55
Insulation class F
Pole-changeable
Number of poles at high speed 4
Number of poles at low speed 8
Installation position horizontal / vertical
Material Sheet steel, galvanised
Weight 41 kg
Nominal size 600 mm
Width 710 mm
Height 745 mm
Depth 400 mm
Airstream temperature at IMax 50 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799860556
Article number 0086.0055
Article DZR 60/84 B
Total efficiency η 59,2 %
Measurement category D
Efficiency category total
Efficiency level N 64,6
VSD necessary No
Year of manufacture see rating plate
Manufacturer’s name / official registration number / manufacturer's place of establishment Maico Elektroapparate-Fabrik GmbH / Freiburg registration court, HRB 601233 / Villingen-Schwenningen
Art. No. 0086.0055
PBEP / Air volumeBEP / Pfs, BEP 1,38 kW / 13.800 m³/h
nBEP 1.440 1/min
Specific ratio ≈ 1
Information about dismantling and disposal see mounting instructions
Information about installation, operation and repairs see mounting instructions
Objects used to measure efficiency which are not described by the measurement category -
pf, BEP 213 Pa
Sound power levelLWA5 70 dB(A) / 90 dB(A)

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, high (dB(A))

49

57

69

73

74

69

62

52

78

LWA2, low (dB(A))

36

52

49

55

53

50

40

30

59

LWA5, high (dB(A))

45

64

82

86

85

81

75

66

90

LWA5, low (dB(A))

37

57

62

66

64

61

54

41

70

LWA8, high (dB(A))

62

69

78

86

86

85

83

80

92

LWA8, low (dB(A))

46

56

63

66

68

68

69

66

75

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA8= housing and free outlet sound power level in dB.

Accessories

DZR 60/84 B - Accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
Shutter AS 60 0151.0337 on request
  • On the notes
Shutter, manual RS 60 0151.0345 on request
  • On the notes
Servomotor MS 2 0093.0403 on request
  • On the notes
Shutter, servomotor VE 60 Discontinued product 0093.0290 on request
  • On the notes
Servomotor MS 8 0157.0760 on request
  • On the notes
Servomotor MS 8 P 0157.0761 on request
  • On the notes
Protective grille, metal SG 60 0150.0122 on request
  • On the notes
Flexible coupling ELA 60 0092.0273 on request
  • On the notes
Flexible cuff EL 60 0092.0093 on request
  • On the notes
Mounting and sealing material BD 60 Discontinued product 0092.0139 on request
  • On the notes
Counter flange GF 60 0056.0009 on request
  • On the notes
Counter socket GS 60 0055.0175 on request
  • On the notes
Suction nozzle AD 60 0180.0627 on request
  • On the notes
Mounting foot FU 60 0036.0077 on request
  • On the notes
Vibration damper GP 20 0092.0152 on request
  • On the notes
Main switch, service switch HS 6 0157.0737 on request
  • On the notes
Rotary switch DS 10 0157.0410 on request
  • On the notes
Pole-changing switch P 1 0157.0103 on request
  • On the notes
Reversing switch, pole-changing switch WP 1 0157.0105 on request
  • On the notes
Contactor US 16 T 0157.0769 on request
  • On the notes
Thermostat THR 10 0157.0774 on request
  • On the notes
Thermostat TH 10 0157.0764 on request
  • On the notes
Thermostat TH 16 0157.0748 on request
  • On the notes
Air flow monitor LW 9 0157.0779 on request
  • On the notes
Hygrostat HY 230 0157.0126 on request
  • On the notes
Hygrostat HY 230 I 0157.0127 on request
  • On the notes
Hygrostat HY 10 AP Discontinued product 0157.0358 on request
  • On the notes
Hygrostat HY 10 UP Discontinued product 0157.0357 on request
  • On the notes
Air quality controller EAQ 10/1 0157.0777 on request
  • On the notes

Product description

Productdescription

DZR 60/84 B

short description

Axial duct fan, DN 600, three-phase AC, pole-changeable

Product description

Features

  • Duct sleeve made of galvanised sheet steel, with flanges on both sides.
  • 8-blade impellers made of glass-fibre filled polyamide. Dynamically balanced at two levels, in accordance with performance level 6.3, DIN ISO 1940, Part 1.
  • Flange holes in accordance with DIN EN 12220:1998.
  • DZR 56/6 B and DZR 56/4 B: Flange holes in accordance with DIN EN 12220:1998.
  • To avoid transmission of vibrations to the duct system: Use flexible couplings, feet and vibration dampers.
  • High degree of protection IP 55. Exception EZR/DZR... D IP 54.
  • Can be fitted in any position.

Motor

  • Asynchronous motor, speed controllable. Exception: Type DZR 40/2 B.
  • Not suitable for ventilating steam-saturated air.
  • Air flow direction is indicated on the unit with direction of rotation and air flow direction arrows.
  • Reversing mode: The volumetric flow is reduced by approx. 35 % with abnormal air flow direction.

Three-phase AC motor

  • DZR model series.
  • Rated voltage 400 V, 50 Hz.
  • Thermal overload protection as a standard feature. Exception: available on request for DZR 25/4 D and pole-changeable axial duct fans. Potential-free terminal connections, which must be connected to e.g. an MV 25 protective motor switch or the control circuit of a contactor.
  • Pole-changeable fans: Ensure overload protection is guaranteed by a motor protection switch provided by the customer.

Electrical connection

  • Terminal box with cable sleeves fitted on the outside.

Safety instructions

  • The fan may be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN 13857.

Special versions

  • The following special versions are available on request, at an extra cost:
    • Special voltages and frequencies.
    • PTC thermistor, potential-free terminal connection.
    • Condensation drainage holes.
    • Fans with enhanced anti-corrosion protection.
    • Impellers made of aluminium.
  • Information on operation at temperatures occasionally below -20°C available upon request.
  • If operating with frequency converters, the factory must be consulted.
  • Feasibility must be checked in each case.

Table of contents

Wiring diagram

DZR 60/84 B - Wiring diagram





Predecessor - successor

DZR 60/84 B - Predecessor

Product type Name Art. No. Action
Axial duct fan DZL 60/84 B No longer available for delivery 0086.0100
  • On the notes

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. OK

Acknowledgements Data protection