Small room fan

ECA 100 KVZ

No longer available for delivery
Article number: 0084.0004
Manufacturer: MAICO
With electrical internal shutter and time delay switch
Application examples: Bathroom, WC, Storage room, Larder, Cellar
ECA 100 KVZ IM0008696.PNG With electrical internal shutter and time delay switch
ECA 100 KVZ IM0007250.PNG With electrical internal shutter and time delay switch
ECA 100 KVZ IM0007252.PNG With electrical internal shutter and time delay switch

Characteristic curve

ECA 100 KVZ - Characteristic curve

  • ECA 100 KVZ IM0002299.PNG With electrical internal shutter and time delay switch

V = 230 or 24 V

f = 50 Hz

n = 2650 min-1

Dimensioned drawing

ECA 100 KVZ - Dimensioned drawing [mm]

  • ECA 100 KVZ IM0007157.PNG With electrical internal shutter and time delay switch
  1. Cable entry

Technical data

ECA 100 KVZ - Technical data

Article ECA 100 KVZ
Model Time delay switch
Air flow volume 95 m³/h
Rotating speed 2.650 1/min
Speed controllable
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz/60 Hz
Power consumption 13 W
Imax 0,1 A
Degree of protection IP 34
Mains cable 5 x 1,5 mm²
Installation site Wall
Type of installation Surface-mounted
Installation position any
Material Synthetic material
Colour Traffic white, similar to RAL 9016
Weight 0,763
Type of shutter electrical
Nominal size 100 mm
Sound pressure level 31 dB(A) / Distance 3 m, Free-field conditions
Packing unit 1 piece
Range A
GTIN (EAN) 4012799840046
Article number 0084.0004

Accessories / Spare parts

ECA 100 KVZ - Accessories / Spare parts

Specific accessories

Product typeNameArt. No.Price*(EUR)Action
Window installation kitFE 100 APDiscontinued product0093.1024 on request
  • On the notes
Window installation kitFE 100 SGDiscontinued product0093.1023 on request
  • On the notes
ShutterAP 1000059.1058 on request
  • On the notes
ShutterAP 100 B0059.0957 on request
  • On the notes
Fly screenFG 1000093.0922 on request
  • On the notes
External grilleSG 1000059.1054 on request
  • On the notes
External grilleSG 100 B0059.0958 on request
  • On the notes
Wall sleeveWH 1000059.1030 on request
  • On the notes
Radio switchXS 1Discontinued product0157.0344 on request
  • On the notes
Radio receiverXE 10157.0343 on request
  • On the notes
Mounting plateZM 110059.0696 on request
  • On the notes
SpacerECA-AHNo longer available for delivery0092.0486 on request
  • On the notes

General accessories

Product typeNameArt. No.Price*(EUR)Action
Roof outletDF---
Roofing tileDP---
Mounting clampBS---
Rain protection grilleRG---
Door ventilation grilleMLK 30 white0151.0123 on request
  • On the notes
Door ventilation grilleMLK 45 white0151.0126 on request
  • On the notes
Flexible aluminium ductAFR 1000055.0090 on request
  • On the notes
Door contact switchTS 8No longer available for delivery0157.0120 on request
  • On the notes

Spare parts

Product typeNameArt. No.Price*(EUR)Action
CoverABDK ECA 100 1E059.1003.9002 on request
  • On the notes
Circuit boardPL ECA 100/120 VZE101.1254.0000 on request
  • On the notes
Thermostatic bimetal stripTB ECA 100 KE180.0913.9000 on request
  • On the notes

Product description

Productdescription

ECA 100 KVZ

short description

With electrical internal shutter and time delay switch

Product description

Model with time delay switch

  • With electrical internal shutter.
  • Start delay approx. 50 seconds.
  • Overrun time approx. 6 minutes.
  • Not speed-controllable.

Features

  • High air volume in spite of compact size.
  • Combines large air volumes with high pressure.
  • Thermal overload protection.
  • Housing made of impact resistant plastic material.
  • Protection class II.
  • With VDE GS symbol.
  • With protective seals to stop ingress of condensation for ceiling installations.
  • Optional speed control for standard ECA fan models.

Motor

  • Robust motor with ball bearings, maintenance-free.
  • Suitable for continuous operation.

Mounting instructions

  • Easy and quick cover dismantling.
  • The fan can be fastened quickly in the duct by the two spring-clamps.

Electrical connection

  • Electrical connection can be either surface- or recessed-mounted.

Safety instructions

  • ECA 100 Can be used in protection area 2 in accordance with DIN VDE 0100-701.
  • For details, please refer to the planning instructions.

Table of contents

Wiring diagram

ECA 100 KVZ - Wiring diagram



Predecessor - successor

ECA 100 KVZ - Successor

Product typeNameArt. No.Action
Small room fanECA 100 ipro KVZC0084.0206
  • On the notes

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. Agreed

Acknowledgements Data protection