Final assembly kit

PPB 30 K

New development
Article number: 0095.0246
Manufacturer: MAICO
Final assembly kit for PushPull Balanced PPB 30 K single-room ventilation unit with heat recovery, comprising... more information
PPB 30 K IM0018181.PNG Final assembly kit for PushPull Balanced PPB 30 K single-room ventilation unit with heat recovery, comprising 2 fans, 2 ceramic heat exchangers, internal cover with 2 x G3 filters, comfort version: with integrated humidity sensor, accessories needed: Shell sleeve, external cover and RLS 45 K room air control, optional accessories: extension kit, wall block, compensating frame and sensors

Characteristic curve

Dimensioned drawing

PPB 30 K - Dimensioned drawing [mm]

  1. Wall sleeve centre
  2. Fixing holes
  3. Cable entry

Technical data

PPB 30 K - Technical data

Article PPB 30 K
Air flow volume 5 m³/h / 12 m³/h / 18 m³/h / 22 m³/h / 26 m³/h
Energy efficiency class A
Rated voltage 12 V DC
SPI value in accordance with DIN EN 13141-8 0,19 Wh/m³
Maximum power consumption 1,7 W / 2,5 W / 3,4 W / 4,4 W / 5,3 W
Degree of protection IP X4
Installation position horizontal
System type Decentralised
Housing material Synthetic material
Heat exchanger material Ceramic
Colour Traffic white, similar to RAL 9016
Weight 4,69 kg
Type of filter Outside and exhaust air filter
Filter class G3/G3
Connection diameter 160 mm
Width 275 mm
Height 275 mm
Depth 585 mm
Wall has to be broken through 162 to 182 mm
Wall thickness 320 mm / 500 mm
Degree of heat provision with reference volumetric flow according to DIN EN 13141-8 73,3 %
Required room air control RLS 45 K
Sound pressure level 23 dB(A) / 35 dB(A) / 43 dB(A) / 48 dB(A) / 51 dB(A) / Distance 1 m, free-field conditions
Rated max. element normal difference in noise level Dn,w 37 dB
Packing unit 1 piece
Range K
EAN 4012799952466
Article number 0095.0246

Accessories

PPB 30 K - Accessories

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Extension kit PPB 30 VS New development 0093.1522 on request
  • On the notes
External cover PPB 30 AK New development 0093.1498 on request
  • On the notes
External cover PPB 30 AE New development 0093.1499 on request
  • On the notes
External cover PPB 30 AW New development 0093.1500 on request
  • On the notes
External cover PPB 30 AS New development 0093.0613 on request
  • On the notes
Extension kit PPB 30 VSDF New development 0059.0870 on request
  • On the notes
Compensating frame PPB 30 ARE New development 0093.1501 on request
  • On the notes
Compensating frame PPB 30 ARW New development 0093.1525 on request
  • On the notes
Air filter, replacement PPB 30 G3 New development 0093.1502 on request
  • On the notes
Shell sleeve PP 45 RHK 0059.0081 on request
  • On the notes
Shell sleeve PP 45 RHL 0059.0082 on request
  • On the notes
Roof outlet duct PP 45 DFK New development 0058.0096 on request
  • On the notes
Roof outlet sleeve PP 45 DFHK New development 0059.0868 on request
  • On the notes
Roof outlet sleeve PP 45 DFHL New development 0059.0869 on request
  • On the notes
Roof cover frame PP 45 DER 25-35 New development 0093.1316 on request
  • On the notes
Roof cover frame PP 45 DER 36-55 New development 0093.1317 on request
  • On the notes
Roof cowl PP 45 DH 25-30 New development 0093.1318 on request
  • On the notes
Roof cowl PP 45 DH 31-35 New development 0093.1319 on request
  • On the notes
Roof cowl PP 45 DH 36-45 New development 0093.1320 on request
  • On the notes
Roof cowl PP 45 DH 46-55 New development 0093.1321 on request
  • On the notes
Room air control RLS 45 K 0157.0360 on request
  • On the notes

Product description

Productdescription

PPB 30 K

short description

Final assembly kit for PushPull Balanced PPB 30 K single-room ventilation unit with heat recovery, comprising 2 fans, 2 ceramic heat exchangers, internal cover with 2 x G3 filters, comfort version: with integrated humidity sensor, accessories needed: Shell sleeve, external cover and RLS 45 K room air control, optional accessories: extension kit, wall block, compensating frame and sensors

Product description

Features

  • Final assembly kits for PushPull Balanced PPB 30 single-room ventilation unit with two fans, two ceramic heat exchangers, internal cover and two integrated filters (G3) such that the air is filtered in both directions.
  • Models:
    • PPB 30 O object model
    • PPB 30 K comfort model with integrated humidity sensor and scope for volumetric flow compensation using PP 45 units
    • PPB 30 RC wireless model with integrated radio board, including humidity sensor and scope for volumetric flow compensation using PP 45 units
  • We recommend using these units in exhaust air rooms (WC, bathroom, kitchen). Degree of protection IP X4 means this can be done with ease.
  • Accessories needed:
    • PP 45 RHK or PP 45 RHL shell sleeve
    • PPB 30 AK, PPB 30 AE, PPB 30 AW or PPB 30 AS external cover
    • RLS 45 K or RLS 45 O room air control. An RLS 45 K or RLS 45 O room air control can be used to construct a wired ventilation system comprising PPB 30 and PP 45 units. The maximum number of fans used is 6. Various combinations are therefore possible, e.g. 2 x PP 45 K/O + 1 x PPB 30 K + 1 x RLS 45 K or 3 x PPB 30 K + 1 x RLS 45 K. A combination of PPB 30 K and RLS 45 O is not permitted.
    • DS 45 RC: The DS 45 RC radio switch can be used to construct a radio-controlled ventilation system comprising PPB 30 RC and PP 45 RC units, e.g. 4 x PP 45 RC + 1 x PPB 30 RC + 1 x DS 45 RC.
    • PP 45 EO: If the RLS 45 K room air control is extended with PP 45 EO, the wired units can be combined with radio units, e.g. 4x PP 45 K/O + 1 x PPB 30 RC + 1 x RLS 45 K + 1 x PP 45 EO.
  • Optional accessories:
    • PPB 30 VS extension kit
    • Wall block PP 45 MB
    • PPB 30 ARE and PPB 30 ARW compensating frames
    • PPB 30 ARE BB and PPB 30 ARW BB fixing plates for compensating frame
    • PP 45 HYI and PP 45 HY humidity sensor
    • PP 45 CO2 CO2 sensor
    • PP 45 VOC VOC sensor
    • Air filter, PPB 30 G3 replacement
  • The PP 45 HYI internal humidity sensor or the PP45 HY, PP 45 CO2 and PP 45 VOC external sensors can be added to the RLS 45 K and RLS 45 O room air controls. The units therefore attain the A energy efficiency class.
  • RLS 45 K and RLS 45 O room air controls can be operated in 5 ventilation levels 5/12/18/22/26 m³/h and 2 operating modes (continuous ventilation with heat recovery, cross-ventilation without heat recovery) and automatic operating mode.
  • What’s more, the RLS 45 K room air control allows the unit to be easily configured using installation software on a PC/laptop (Windows). The settings can be stored as a profile and transferred to other controllers.

Functions

  • The recommended combination option is 2 x or 4 x PP 45 O/K + 1 x PPB 30 K + 1 x RLS 45 K.
  • The recommended combination option for a wireless system is 2 x or 4 x PP 45 RC + 1 or 2 x PPB 30 RC + 1 x DS 45 RC.
    • In this case, the PPB 30 K/RC unit can be operated in two different operating modes. When in automatic mode, the unit runs completely independently depending on the humidity value of the integrated sensor. When in automatic mode, only the “External Off” and “Ventilation level 0” commands are undertaken by the RLS 45 K room air control and/or DS 45 RC radio switch. When in system mode, the unit runs fully in line with the requirements of the RLS 45 K room air control and/or DS 45 RC radio switch. Only in the event of humidity (limit value can be set) will the unit disconnect from the system and start dehumidification.
    • Automatic dehumidification can be set as intensive ventilation mode (level 5 with heat recovery) or as exhaust air mode (45m³/h without heat recovery).
    • In the event of odours, intensive ventilation mode (level 5 with heat recovery) or exhaust air mode (45m³/h without heat recovery) can also be triggered manually with a button/switch. The duration of this function can be set (factory setting = 10 min).
    • If the PPB 30 K or PPB 30 RC is running in exhaust air mode, the PP 45 units connected to the RLS 45 K room air control or taught in on the DS 45 RC radio switch ensure the necessary supply air. PPB 30 K and exhaust air units (e.g. ER/ECA) cannot be combined with an RLS 45 K room air control.
  • One low-cost solution for a bathroom could be a combination of 1 x PPB 30 O + 1 x RLS 45 O. (Notice: the room air control has IP 00 degree of protection). An exhaust air mode of 45 m³/h (without heat recovery and without volumetric flow compensation) is also possible.

Heat exchanger

  • Thanks to the high-performance heat exchangers and high-efficiency EC fans, the units achieve a degree of heat provision of 73 % at reference volumetric flow according to EN 13141-8.

Mounting information

  • Mounting involves 2 steps:
    • Installation of the PP 45 RHK (DN 160) or RHL (DN 160) shell sleeve and an external cover in a DN 160 core drill hole with an inclination of 1-2 %.
    • We recommend drilling a DN 182 core hole and using the polystyrene shims provided to align the inclination of the sleeve.
    • The shell sleeve is protected from contamination by plaster protective covers.
    • Then the final assembly kit is integrated.
    • No ducts have to be laid and the system does not have to be adjusted.

Electrical connection

  • When delivered, the unit is assembled and ready for service.
  • The electrical supply is connected using a plug connection.
  • Connection to RLS 45 K or RLS 45 O room air control using pluggable control cables.
  • The 12 VDC power cable of the RLS 45 K / RLS 45 O room air control to the unit is also the control cable.
  • The PPB30 RC is connected directly to 230V. NOTICE: Check unit’s application area (protection zone).

Condensation drain

  • The condensate is removed via an integrated condensation drop catcher in the external cover.

Table of contents

Wiring diagram

PPB 30 K - Wiring diagram

RLS 45 K - PushPull 45 Comfort room air control

PP 45 K - PushPull 45 Comfort fan unit

PPB 30 K - PushPull Balanced 30 Comfort fan unit

Fan 1.1 - fan unit 1, unit pair 1

Fan 2.1 - fan unit 2, unit pair 1

Fan 1.2 - fan unit 1, unit pair 2

Fan 2.2 - fan unit 2, unit pair 2

S1 - Button/switch for additional function (sleep, intensive, disbalance, safety function)

UP-L - Recessed-mounted distributor connection, connection of all fan units in star shape to distributor

W-F1 - Fan 1 control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. length to distributor 4m.

W-F2 - Fan 2 control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. length to distributor 4m.

W-B1 - Bus PPB control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. length to distributor 4m.

W1.X - Fan unit control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25 m.

W2.X - Fan unit control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25 m.

W-PPB - BBP 30 (bus) control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25 m.

W3 - Fan 1 control cable, recommended control cable J-Y(ST)Y



PP 30 K - PPB 30 Comfort fan unit

VAP-K - Comfort fan connection board

PPB 30 - Fan 1 - Fan 1 connecting cable

PPB 30 - Fan 2 - Fan 2 connecting cable

S1 - Switch/pushbutton for exhaust air mode/intensive ventilation (function/times selected via PushPull IBS)

W-PPB - PPB 30 K connecting cable to RLS 45 K via bus (RS-485), recommended control cable J-Y(ST)Y 2x2x0.8mm². Max. cable length to the PPB 30 K, 25 metres from the star point.

W3 - Connecting cable switch/pushbutton for activation of special functions (exhaust air mode, intensive ventilation), recommended control cable LiYY 2*0.5 mm². Max. cable length 25 metres.



Predecessor - successor

PPB 30 K - Predecessor

Product type Name Art. No. Action
Final assembly kit WRG 35H-SE Discontinued product 0082.0234
  • On the notes

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. OK

Acknowledgements Data protection