Fan insert

ER 100 GVZ

Article number: 0084.0139
Manufacturer: MAICO
Fan insert with cover and filter for installation in recessed-mounted housings, air volume 101 m³/h, with base... more information
Application examples: Bathroom, Kitchen, Multiple family unit, Day room, Dining room
ER 100 GVZ IM0009919.PNG Fan insert with cover and filter for installation in recessed-mounted housings, air volume 101 m³/h, with base load circuit and time delay switch
ER 100 GVZ IM0008446.PNG Fan insert with cover and filter for installation in recessed-mounted housings, air volume 101 m³/h, with base load circuit and time delay switch
ER 100 GVZ IM0007254.PNG Fan insert with cover and filter for installation in recessed-mounted housings, air volume 101 m³/h, with base load circuit and time delay switch
ER 100 GVZ IM0007258.PNG Fan insert with cover and filter for installation in recessed-mounted housings, air volume 101 m³/h, with base load circuit and time delay switch
ER 100 GVZ IM0007252.PNG Fan insert with cover and filter for installation in recessed-mounted housings, air volume 101 m³/h, with base load circuit and time delay switch
ER 100 GVZ IM0007256.PNG Fan insert with cover and filter for installation in recessed-mounted housings, air volume 101 m³/h, with base load circuit and time delay switch

Characteristic curve

ER 100 GVZ - Characteristic curve

  • ER 100 GVZ IM0004577.PNG Fan insert with cover and filter for installation in recessed-mounted housings, air volume 101 m³/h, with base load circuit and time delay switch

Dimensioned drawing

ER 100 GVZ - Dimensioned drawing [mm]

  • ER 100 GVZ IM0002228.PNG Fan insert with cover and filter for installation in recessed-mounted housings, air volume 101 m³/h, with base load circuit and time delay switch

ER fan insert with recessed-mounted housing ER-UP/G or ER-UPD

ER 100 GVZ - Dimensioned drawing [mm]

  • ER 100 GVZ IM0002227.PNG Fan insert with cover and filter for installation in recessed-mounted housings, air volume 101 m³/h, with base load circuit and time delay switch

ER fan insert with recessed-mounted housing ER-UP/G or ER-UPD and second room connection

Technical data

ER 100 GVZ - Technical data

Article ER 100 GVZ
Model Base load and delay time circuit
Air flow volume 35 m³/h / 101 m³/h
Rotating speed 850 1/min / 1.900 1/min
Air direction Air extraction
Speed controllable
SEC average -6,5 kWh/(m²*a)
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Power consumption 9 W / 29,5 W
Imax 0,09 A / 0,14 A
Degree of protection IP X5
Mains cable 5 x 1,5 mm²
Installation site Wall / Ceiling
Type of installation Recessed-mounted
System type Decentralised
Material Synthetic material
Colour Traffic white, similar to RAL 9016
Weight 1,5 kg
Filter class G2
Air outlet direction at side
Width 250 mm
Height 250 mm
Depth 150 mm
Airstream temperature at IMax 40 °C
Overrun time 6 min
Start delay 50 s
Sound pressure level 26 dB(A) / 45 dB(A) / Specifications in accordance with DIN 18017-3 at an equivalent absorption area AL = 10 m.2
Packing unit 1 piece
Range B
GTIN (EAN) 4012799841395
Article number 0084.0139

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA7, low (dB(A))

30

LWA7, high (dB(A))

49

LWA7= housing and free inlet sound power level in dB.

Accessories / Spare parts

ER 100 GVZ - Accessories / Spare parts

Specific accessories

Product typeNameArt. No.Price*(EUR)Action
Recessed-mounted housingER - UP/G0093.0995 on request
  • On the notes
Recessed-mounted housingER - UPD0093.0972 on request
  • On the notes
Recessed-mounted housingER - UPB0093.0968 on request
  • On the notes
Recessed-mounted housingER - UPB/R0093.0969 on request
  • On the notes
Recessed-mounted housingER - UPB/L0093.0970 on request
  • On the notes
Recessed-mounted housingER - UPB/U0093.0971 on request
  • On the notes
Air filter, replacementZF 60/100New development0093.0331 on request
  • On the notes
Air filter, replacementZF 60/100No longer available for delivery0093.0680 on request
  • On the notes
Air filter, replacementZF 60/100 bulk container0093.0885 on request
  • On the notes
Masking frameER-AR0059.0899 on request
  • On the notes
Spacing frameDR 60/1000059.0928 on request
  • On the notes
Second room extraction systemER-ZR0093.1025 on request
  • On the notes
Sound-absorbing elementER-SE UP0192.0678 on request
  • On the notes

General accessories

Product typeNameArt. No.Price*(EUR)Action
Flexible aluminium ductAFR---
Roof outletDF---
Roofing tileDP---
Mounting clampBS---
Rain protection grilleRG---
Outside air openingALD 100152.0054 on request
  • On the notes
Outside air openingALD 1250152.0067 on request
  • On the notes
Outside air openingALD 125 VA0152.0068 on request
  • On the notes
Outside air openingALD 1600152.0069 on request
  • On the notes
Outside air openingALD 160 VA0152.0070 on request
  • On the notes
Outside air openingZE 45 F whiteNo longer available for delivery0152.0044 on request
  • On the notes
Door ventilation grilleMLK 30 white0151.0123 on request
  • On the notes
Door ventilation grilleMLK 45 white0151.0126 on request
  • On the notes
Radio switchXS 10157.0344 on request
  • On the notes
Radio receiverXE 10157.0343 on request
  • On the notes
HygrostatHY 2300157.0126 on request
  • On the notes
HygrostatHY 230 I0157.0127 on request
  • On the notes
Outside air openingALD 10 TNo longer available for delivery0152.0055 on request
  • On the notes

Spare part for

Product typeNameArt. No.Price*(EUR)Action
CoverABD ER 60/100/CentroE059.1017.9000 on request
  • On the notes
Circuit boardPL ER 100 GVZE101.1015.9502 on request
  • On the notes

Product description

Productdescription

ER 100 GVZ

short description

Fan insert with cover and filter for installation in recessed-mounted housings, air volume 101 m³/h, with base load circuit and time delay switch

Product description

Model with base load circuit and time delay switch

  • The unit runs in continuous operation at 35 m3/h.
  • Switching to full load with start delay of approx. 50 sec.
  • Full load overrun time approx. 6 min.
  • Not speed-controllable.
  • Switching variation: The base load can be switched on or off by an additional switch (see the wiring diagrams online).

Features

  • Fan with cover and G2 filter for installation in recessed housings.
  • For single or second room air extraction using a single fan (exception: model H and GVZC EC).
  • Electrical plug connection for quick fan installation in the housing.
  • Trouble-free filter change without using tools.
  • It is possible to rotate the cover by ± 5°, to compensate for housings which have been fitted at an angle.
  • The housing has easy to install snap-in fan fittings.
  • Colour: traffic white, similar to RAL 9016.
  • All MAICO ER units have an IP X5 degree of protection and can be installed in area 1 in accordance with DIN VDE 0100-701, even with water jets. For details see planning instructions.
  • Protection class II.
  • The extremely steep characteristic curve shows the high pressure capacity of the ER fans.
  • Robust energy saving capacitor motor.
  • ER 60 GVZC EC: with energy-saving EC motor.
  • Motor with thermal overload protection.
  • Maintenance-free, with enclosed ball bearings on both sides.
  • Volumetric flow characteristic curve and air leakage rate checked by TÜV Bayern e.V (German Technical Inspection Agency). Air leakage rate < 0.01 m3/h.
  • Shaft level difference according to DIN 4109, tested by IAB Oberursel (The Institute for Acoustics and Building Physics in Germany).
  • With VDE symbol.

Table of contents

Wiring diagram

ER 100 GVZ - Wiring diagram

Switching option 1

Fan always runs at base load. When the room is in use (S1=On), the fan switches automatically to full load after approx. 50 seconds.



Switching option 2

When the room is in use (S1=On), the fan switches automatically to full load after approx. 50 seconds. Base load operation can be switched off manually with switch S2.



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. Agreed

Acknowledgements Data protection