Fan insert

ER 60 GVZC EC

No longer available for delivery
Article number: 0084.0116
Manufacturer: MAICO
Fan insert with EC motor, cover and filter for installation in recessed-mounted housings, air volume 62 m³/h,... more information
Application examples: Bathroom, Kitchen, Multiple family unit, Day room, Dining room
ER 60 GVZC EC IM0009919.PNG Fan insert with EC motor, cover and filter for installation in recessed-mounted housings, air volume 62 m³/h, with base load circuit and time delay switch
ER 60 GVZC EC IM0008446.PNG Fan insert with EC motor, cover and filter for installation in recessed-mounted housings, air volume 62 m³/h, with base load circuit and time delay switch
ER 60 GVZC EC IM0007254.PNG Fan insert with EC motor, cover and filter for installation in recessed-mounted housings, air volume 62 m³/h, with base load circuit and time delay switch
ER 60 GVZC EC IM0007258.PNG Fan insert with EC motor, cover and filter for installation in recessed-mounted housings, air volume 62 m³/h, with base load circuit and time delay switch
ER 60 GVZC EC IM0007252.PNG Fan insert with EC motor, cover and filter for installation in recessed-mounted housings, air volume 62 m³/h, with base load circuit and time delay switch
ER 60 GVZC EC IM0007256.PNG Fan insert with EC motor, cover and filter for installation in recessed-mounted housings, air volume 62 m³/h, with base load circuit and time delay switch

Characteristic curve

ER 60 GVZC EC - Characteristic curve

  1. Base load
  2. Nominal load

Dimensioned drawing

ER 60 GVZC EC - Dimensioned drawing [mm]

ER fan insert with recessed-mounted housing ER-UP/G or ER-UPD

ER 60 GVZC EC - Dimensioned drawing [mm]

ER fan insert with recessed-mounted housing ER-UP/G or ER-UPD and second room connection

Technical data

ER 60 GVZC EC - Technical data

Article ER 60 GVZC EC
Model EC model with base load and time delay switching.
Air flow volume 35 m³/h / 62 m³/h
Rotating speed 850 1/min / 1.250 1/min
Air direction Air extraction
Speed controllable
SEC average -12,77 kWh/(m²*a)
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Power consumption 3,9 W / 6 W
Imax 0,03 A / 0,05 A
Degree of protection IP X5
Mains cable 5 / 1,5 mm²
Installation site Wall / Ceiling
Type of installation Recessed-mounted
System type Decentralised
Material Synthetic material
Colour Traffic white, similar to RAL 9016
Weight 1,7 kg
Filter class G2
Air outlet direction at side
Width 280 mm
Height 280 mm
Depth 160 mm
Airstream temperature at IMax 40 °C
Overrun time 0 min / 1 min / 3 min / 6 min / 15 min
Start delay 0 min / 0,5 min / 1 min / 2 min / 3 min
Packing unit 1 piece
Range B
GTIN (EAN) 4012799841166
Article number 0084.0116

Accessories

ER 60 GVZC EC - Accessories

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Recessed-mounted housing ER - UP/G 0093.0995 on request
  • On the notes
Recessed-mounted housing ER - UPD 0093.0972 on request
  • On the notes
Recessed-mounted housing ER - UPB 0093.0968 on request
  • On the notes
Recessed-mounted housing ER - UPB/R 0093.0969 on request
  • On the notes
Recessed-mounted housing ER - UPB/L 0093.0970 on request
  • On the notes
Recessed-mounted housing ER - UPB/U 0093.0971 on request
  • On the notes
Air filter, replacement ZF 60/100 0093.0680 on request
  • On the notes
Air filter, replacement ZF 60/100 bulk container 0093.0885 on request
  • On the notes
Masking frame ER-AR 0059.0899 on request
  • On the notes
Spacing frame DR 60/100 0059.0928 on request
  • On the notes
Sound-absorbing element ER-SE UP New development 0192.0678 on request
  • On the notes

General accessories

Product type Name Art. No. Price*(EUR) Action
Flexible aluminium duct AFR - - -
Roof outlet DF - - -
Roofing tile DP - - -
Mounting clamp BS - - -
Rain protection grille RG - - -
Outside air opening ALD 10 0152.0054 on request
  • On the notes
Outside air opening ALD 125 0152.0067 on request
  • On the notes
Outside air opening ALD 125 VA 0152.0068 on request
  • On the notes
Outside air opening ALD 160 0152.0069 on request
  • On the notes
Outside air opening ALD 160 VA 0152.0070 on request
  • On the notes
Outside air opening ZE 45 F white Discontinued product 0152.0044 on request
  • On the notes
Door ventilation grille MLK 30 white 0151.0123 on request
  • On the notes
Door ventilation grille MLK 45 white 0151.0126 on request
  • On the notes
Radio switch XS 1 0157.0344 on request
  • On the notes
Radio receiver XE 1 0157.0343 on request
  • On the notes
Timer ZS 4 0157.0088 on request
  • On the notes
Hygrostat HY 230 0157.0126 on request
  • On the notes
Hygrostat HY 230 I 0157.0127 on request
  • On the notes
Hygrostat HY 10 AP Discontinued product 0157.0358 on request
  • On the notes
Hygrostat HY 10 UP Discontinued product 0157.0357 on request
  • On the notes
Outside air opening ALD 10 T No longer available for delivery 0152.0055 on request
  • On the notes

Product description

Productdescription

ER 60 GVZC EC

short description

Fan insert with EC motor, cover and filter for installation in recessed-mounted housings, air volume 62 m³/h, with base load circuit and time delay switch

Product description

Model with EC motor, base load circuit and time delay

  • The unit runs in continuous operation at 35 m3/h.
  • Switching to full load with adjustable start delay (0/0.5/1/2/3 minutes).
  • Adjustable overrun time of the full load level (0/1/3/6/15 minutes).
  • Not speed-controllable.
  • Switching variation: The base load can be switched on or off by an additional switch (see the wiring diagrams online).

Features

  • Fan with cover and G2 filter for installation in recessed housings.
  • For single or second room air extraction using a single fan (exception: model H and GVZC EC).
  • Electrical plug connection for quick fan installation in the housing.
  • Trouble-free filter change without using tools.
  • It is possible to rotate the cover by ± 5°, to compensate for housings which have been fitted at an angle.
  • The housing has easy to install snap-in fan fittings.
  • Colour: traffic white, similar to RAL 9016.
  • All MAICO ER units have an IP X5 degree of protection and can be installed in area 1 in accordance with DIN VDE 0100-701, even with water jets. For details see planning instructions.
  • Protection class II.
  • The extremely steep characteristic curve shows the high pressure capacity of the ER fans.
  • Robust energy saving capacitor motor.
  • ER 60 GVZC EC: with energy-saving EC motor.
  • Motor with thermal overload protection.
  • Maintenance-free, with enclosed ball bearings on both sides.
  • Volumetric flow characteristic curve and air leakage rate checked by TÜV Bayern e.V (German Technical Inspection Agency). Air leakage rate < 0.01 m3/h.
  • Shaft level difference according to DIN 4109, tested by IAB Oberursel (The Institute for Acoustics and Building Physics in Germany).
  • With VDE symbol.

Table of contents

Wiring diagram

ER 60 GVZC EC - Wiring diagram

Standard switching:

The fan permanently runs at least at base load. The base load level cannot be switched off manually. If the room lighting is switched on (S1 = On), the fan switches to nominal load after the preset start delay of 0 to three minutes.

After the room lighting is switched off, the fan continues running up to 15 minutes at an adjustable overrun time. Then the fan switches back to the base load level.



Switching option

When the room is in use (S1=On), the fan switches automatically to full load after approx. 50 seconds. Base load operation can be switched off manually with switch S2.

The base load can be switched on and off with S2.

Case 1: Fan is stationary. If S2 is activated (S2 = On), the unit switches immediately to base load, without considering the preset start delay. If S2 is activated again, (S2 = Off), the unit switches immediately off, without considering the preset overrun time.

Case 2: The unit is running at base load level (S2 = On). If the room lighting is switched on (S1 = On), the fan switches to nominal load after an adjustable start delay of 0 to 3 minutes. After the room lighting is switched off, the fan continues running up to 15 minutes at the adjustable overrun time. Then the fan switches back to the base load level.

Case 3: Fan is stationary. If the room lighting is switched on (S1 = On), the fan switches to nominal load after an adjustable start delay of 0 to 3 minutes. After the room lighting is switched off, the fan continues running up to 15 minutes at the adjustable overrun time. Then the fan switches off.

When setting the overrun time, please take the General Building Approval into consideration.



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. OK

Acknowledgements Data protection