Surface-mounted fan

ER-AP 100 H

Article number: 0084.0174
Manufacturer: MAICO
Surface-mounted fan for air extraction, air volume 100 m³/h, with humidity control and base load circuit
Application examples: Bathroom, Kitchen, Multiple family unit, Day room, Dining room
ER-AP 100 H IM0009918.PNG Surface-mounted fan for air extraction, air volume 100 m³/h, with humidity control and base load circuit
ER-AP 100 H IM0008446.PNG Surface-mounted fan for air extraction, air volume 100 m³/h, with humidity control and base load circuit
ER-AP 100 H IM0007254.PNG Surface-mounted fan for air extraction, air volume 100 m³/h, with humidity control and base load circuit
ER-AP 100 H IM0007256.PNG Surface-mounted fan for air extraction, air volume 100 m³/h, with humidity control and base load circuit

Characteristic curve

ER-AP 100 H - Characteristic curve

  • ER-AP 100 H IM0004608.PNG Surface-mounted fan for air extraction, air volume 100 m³/h, with humidity control and base load circuit

Dimensioned drawing

ER-AP 100 H - Dimensioned drawing [mm]

  • ER-AP 100 H IM0002185.PNG Surface-mounted fan for air extraction, air volume 100 m³/h, with humidity control and base load circuit

Technical data

ER-AP 100 H - Technical data

Article ER-AP 100 H
Model Humidity control
Air flow volume 35 m³/h / 100 m³/h
Rotating speed 900 1/min / 1.850 1/min
Air direction Air extraction
Speed controllable
SEC average -21,88 kWh/(m²*a)
Rated voltage 230 V
Frequency 50 Hz
Power consumption 10 W / 29 W
Imax 0,09 A / 0,15 A
Degree of protection IP X5
Mains cable 5 x 1,5 mm²
Installation site Wall / Ceiling
Type of installation Surface-mounted
System type Decentralised
Material Synthetic material
Colour Traffic white, similar to RAL 9016
Weight 1,9 kg
Filter class G2
Fire protection No
Connection diameter 75 mm / 80 mm
Width 236 mm
Height 236 mm
Depth 217,5 mm
Airstream temperature at IMax 40 °C
Overrun time 6 min
Overrun time / Overrun time available when using an optional switch (e.g. light switch)
Sound pressure level 33 dB(A) / 49 dB(A) / Specifications in accordance with DIN 18017-3 at an equivalent absorption area AL = 10 m.2
Approval number Z-51.1-42
Packing unit 1 piece
Range B
GTIN (EAN) 4012799841746
Article number 0084.0174

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA7, low (dB(A))

37

LWA7, high (dB(A))

53

LWA7= housing and free inlet sound power level in dB.

Accessories / Spare parts

ER-AP 100 H - Accessories / Spare parts

Specific accessories

Product typeNameArt. No.Price*(EUR)Action
Air filter, replacementZF 60/100New development0093.0331 on request
  • On the notes
Air filter, replacementZF 60/100No longer available for delivery0093.0680 on request
  • On the notes
Air filter, replacementZF 60/100 bulk container0093.0885 on request
  • On the notes
Sound-absorbing elementER-SE AP0192.0679 on request
  • On the notes

General accessories

Product typeNameArt. No.Price*(EUR)Action
Flexible aluminium ductAFR---
Roof outletDF---
Roofing tileDP---
Mounting clampBS---
Rain protection grilleRG---
Outside air openingALD 100152.0054 on request
  • On the notes
Outside air openingALD 1250152.0067 on request
  • On the notes
Outside air openingALD 125 VA0152.0068 on request
  • On the notes
Outside air openingALD 1600152.0069 on request
  • On the notes
Outside air openingALD 160 VA0152.0070 on request
  • On the notes
Outside air openingZE 45 F whiteNo longer available for delivery0152.0044 on request
  • On the notes
Door ventilation grilleMLK 30 white0151.0123 on request
  • On the notes
Door ventilation grilleMLK 45 white0151.0126 on request
  • On the notes
Radio switchXS 10157.0344 on request
  • On the notes
Radio receiverXE 10157.0343 on request
  • On the notes
Outside air openingALD 10 TNo longer available for delivery0152.0055 on request
  • On the notes

Spare part for

Product typeNameArt. No.Price*(EUR)Action
CoverABD AP ER 60/100/CentroE059.1037.0001 on request
  • On the notes
Shutter support with backflow preventerKA RK KE093.0608.0001 on request
  • On the notes
HousingGH AP ER 60/100/CentroE059.1036.9001 on request
  • On the notes
Terminal blockKL ERE157.0326.0000 on request
  • On the notes
Circuit boardPL ER 100 HE101.1015.9207 on request
  • On the notes
Fan insertVE ER-AP 100 HE084.0174.0000 on request
  • On the notes

Product description

Productdescription

ER-AP 100 H

short description

Surface-mounted fan for air extraction, air volume 100 m³/h, with humidity control and base load circuit

Product description

Model with humidity control and base load circuit

  • Barrier-free product as the fan switches itself on and off automatically.
  • Switch-on point: 60 %, 70 %, 80 % or 90 % relative humidity can be set with jumper.
  • Switch-off point: approx. 10 % below the switch-on point (always a fixed set value).
  • Not speed-controllable.
  • Not suitable for second room ventilation.
  • Can be operated manually via a switch, e.g. switching full load on using a light switch.
  • Standard switching: Fan runs in base load operation, humidity control is active, full load operation if the switch-on point is exceeded, base load operation if level falls below the switch-off point.
  • Other switch variants: Fan mode with or without base load operation; manual engagement of full load; switching fan on or off using a switch.
  • Activation of full load using light switch and a fan overrun control linked to this (6 minute overrun time).
  • The fan always overruns until the air humidity in the room has fallen below the switch-off humidity level, regardless of the switch variants.

Features

  • Surface-mounted fan with G2 filter for air extraction in domestic kitchens, bathrooms or WCs.
  • Trouble-free filter exchange without using tools.
  • Housing can be turned, so the exhaust socket can be connected to main duct in the top left or top right..
  • Colour: traffic white, similar to RAL 9016.
  • DN 75/80 plastic exhaust socket with airstream-operated synthetic backflow preventer.
  • The extremely steep characteristic curve shows the high pressure capacity of the ER fans.
  • All MAICO ER units have an IP X5 degree of protection and can be installed in area 1 in accordance with DIN VDE 0100-701, even with water jets. For details, please refer to the planning instructions.
  • Protection class II.
  • Robust energy saving capacitor motor.
  • Maintenance-free, with enclosed ball bearings on both sides.
  • Electrical plug connection for quick fan installation in the housing.
  • General official approval, approval no.: Z-51.1-42.
  • Certificates of approval on request or on our website - www.maico-fans.com.
  • Volumetric flow characteristic curve and air leakage rate checked by TÜV Bayern e.V (German Technical Inspection Agency). Air leakage rate < 0.01 m3/h.
  • Shaft level difference according to DIN 4109, tested by IAB Oberursel (The Institute for Acoustics and Building Physics in Germany).
  • With VDE symbol.

Table of contents

Wiring diagram

ER-AP 100 H - Wiring diagram

The fan always runs at the base load. If the humidity is higher than the switch-on humidity, the fan will automatically switch to full load.



Switching option 1

The fan always runs at the base load. If the humidity is higher than the switch-on humidity, the fan will automatically switch to full load. In addition, it is possible to switch to full load with switch S1.



Switching option 2

Switch S1 is used to manually switch the fan to the base load. If the humidity is higher than the switch-on humidity, the fan will automatically switch to full load.



Switching option 3

Switch S1 is used to manually switch the fan on and off. The fan will continue to run until the humidity in the room has fallen below the switch-off humidity.



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. Agreed

Acknowledgements Data protection