Sound-insulated ventilation box

ESR 20 S

No longer available for delivery
Article number: 0080.0229
Manufacturer: MAICO
Sound-insulated ventilation box with swivelling fan, DN 200, single-phase AC

Characteristic curve

ESR 20 S - Characteristic curve

Dimensioned drawing

ESR 20 S - Dimensioned drawing [mm]

Technical data

ESR 20 S - Technical data

Article ESR 20 S
Air flow volume 890 m³/h
Rotating speed 2.490 1/min
Speed controllable
Type of voltage Alternating current
Rated voltage 230 V
Nominal output 190 W
Inom 0,84 A
Imax 0,9 A
Weight 20
Swivelling fan
Nominal size 200 mm
Airstream temperature at nominal current 55 °C
Ambient temperature 55 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799802297
Article number 0080.0229

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA5, S5 (dB(A))

46

56

55

48

47

46

38

60

LWA6, S5 (dB(A))

54

63

72

69

68

62

55

75

LWA2, S5 (dB(A))

46

48

54

37

31

29

23

56

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

Accessories

ESR 20 S - Accessories

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Automatic backflow preventer AVM 20 0093.0006 on request
  • On the notes
Tubular sound absorber RSR 20 0092.0316 on request
  • On the notes
Tubular sound absorber RSR 20/50 0092.0326 on request
  • On the notes
Electrical air heater ERH 20-2 0082.0103 on request
  • On the notes
Electrical air heater DRH 20-5 0082.0106 on request
  • On the notes
Electrical air heater with controller DRH 20-6 R 0082.0144 on request
  • On the notes
Water air heater WRH 20-2 0082.0119 on request
  • On the notes
Air filter TFE 20-4 0149.0078 on request
  • On the notes
Air filter TFE 20-5 0149.0062 on request
  • On the notes
Air filter TFE 20-7 0149.0053 on request
  • On the notes
Heat exchanger WT 750 No longer available for delivery 0152.0041 on request
  • On the notes

General accessories

Product type Name Art. No. Price*(EUR) Action
Shutter AS 20 0151.0330 on request
  • On the notes
External grille MLA 20 0151.0111 on request
  • On the notes
External grille MLZ 20 0151.0101 on request
  • On the notes
Protective grille SGR 20 0150.0126 on request
  • On the notes
Speed controller ST 1 No longer available for delivery 0157.0810 on request
  • On the notes
Speed controller, distribution board STS 2,5 No longer available for delivery 0157.0255 on request
  • On the notes
5-step switch for TRE...S -2/ TR...S-2 5-step transformers ESS 20 0157.0749 on request
  • On the notes
Speed controller STU 1 No longer available for delivery 0157.0814 on request
  • On the notes
TRE 1,6 No longer available for delivery 0016.0112 on request
  • On the notes
5-step transformer, control cabinet TRE 1,6 S No longer available for delivery 0157.0744 on request
  • On the notes

Product description

Productdescription

ESR 20 S

short description

Sound-insulated ventilation box with swivelling fan, DN 200, single-phase AC

Table of contents

Wiring diagram

ESR 20 S - Wiring diagram



Duct fan with ERH 16-2 R electric air heater

S1 - system on

US16 - all-pole isolating switch (contactor)

ERR... centrifugal duct fan

ERH...R electrical air heater: ERH16-2R

B=Int/ext bridge must be closed

C=Do not change potentiometer setting

D=Setpoint potentiometer for MIN limitation

E=Setpoint potentiometer for MAX limitation

F=Bridge for MAX limitation, bridge must be closed!

G=If bridge is closed, MIN limitation is also active

FR30P - ext. setpoint controller (0-30°C) with room sensor

FL30P - ext. channel sensor for MIN, MAX limitation

LW9 - air flow monitor (in position N)

Installation of LW9 sensor on incoming side of air heater

0-30°C setpoint setting and recording of room temperature with FR30P

0-60°C min/max limitation in supply air channel with FL60P



Duct fan with electric air heater DRH 16-5R and DRH 20-6R

S1 - system on

US16 - all-pole isolating switch (contactor)

ERR... centrifugal duct fan

DRH...R electric air heater: DRH16-2R or DRH20-6R

B=Int/ext bridge must be closed

C=Do not change potentiometer setting

D=Setpoint potentiometer for MIN limitation

E=Setpoint potentiometer for MAX limitation

F=Bridge for MAX limitation, bridge must be closed!

G=If bridge is closed, MIN limitation is also active

FR30P - ext. setpoint controller (0-30°C) with room sensor

FL30P - ext. channel sensor for MIN, MAX limitation

LW9 - air flow monitor (in position N)

Installation of LW9 sensor on incoming side of air heater

0-30°C setpoint setting and recording of room temperature with FR30P

0-60°C min/max limitation in supply air channel with FL60P



Predecessor - successor

ESR 20 S - Successor

Product type Name Art. No. Action
Sound-insulated ventilation box ESR 20-2 S No longer available for delivery 0080.0619
  • On the notes

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. OK

Acknowledgements Data protection