Temperature control system

DTL 24 P

Article number: 0157.0586
Manufacturer: MAICO
Electronic temperature controller for controlling the DHP electrical air heater
DTL 24 P IM0009878.PNG Electronic temperature controller for controlling the DHP electrical air heater

Characteristic curve

Dimensioned drawing

Technical data

DTL 24 P - Technical data

Article DTL 24 P
Type of voltage Three-phase AC
Rated voltage 400 V
PMax 16.500 W
Maximum load 24 A
Degree of protection IP 20
Type of installation Surface-mounted
Weight 1,6 kg
Width 200 mm
Height 290 mm
Depth 195 mm
Packing unit 1 piece
Range D
GTIN (EAN) 4012799575863
Article number 0157.0586

Accessories / Accessories of

DTL 24 P - Accessories / Accessories of

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Power board DTL 2 P-L 0157.0587 on request
  • On the notes
Channel sensor FL 30 P 0157.0780 on request
  • On the notes
Room sensor FR 30 P 0157.0781 on request
  • On the notes

is a special accessory of

Product type Name Art. No. Price*(EUR) Action
Electrical air heater For DHP channel systems - - -

is a general accessory of

Product type Name Art. No. Price*(EUR) Action
Channel fan EPK, DPK 500 x 300 channel fans - - -
Channel fan EPK, DPK 600 x 300 channel fans - - -
Channel fan EPK, DPK 600 x 350 channel fans - - -
Channel fan DPK 22 EC 0086.0800 on request
  • On the notes
Channel fan DPK 31 EC 0086.0802 on request
  • On the notes
Channel fan DPK 31-S EC 0086.0804 on request
  • On the notes
Sound-insulated channel fan DSK 22 EC 0086.0801 on request
  • On the notes
Sound-insulated channel fan DSK 31 EC 0086.0803 on request
  • On the notes
Sound-insulated channel fan DSK 31-S EC 0086.0805 on request
  • On the notes
Channel fan EPK 22/4 B No longer available for delivery 0086.0651 on request
  • On the notes
Channel fan DPK 22/4 B No longer available for delivery 0086.0661 on request
  • On the notes
Sound-insulated channel fan DSK 31/4 No longer available for delivery 0086.0645 on request
  • On the notes

Product description

Productdescription

DTL 24 P

short description

Electronic temperature controller for controlling the DHP electrical air heater

Product description

  • Electronic temperature controller for controlling the DHP electrical air heater.
  • Night reduction can be set from 0 K to 4 K below the setpoint temperature.
  • Triac regulator with pulse packet control.
  • Control via 0 V to 10 V possible.
  • To increase power up to 30 kW, use DTL 2 P-L.

Table of contents

Wiring diagram

DTL 24 P - Wiring diagram

DTL 24 P combined with EPK / DPK channel fan and DHP electrical air heater

S1 - system off switch

S2 - system on switch

K1 - Fan on (US 16 contactor)

LW 9 - air flow monitor

DHP .. - Electrical air heater

F1 - temperature limiter

F2 - safety temperature limiter

K2 - heating release (K2 must be supplied by customer)

DPK..B - Centrifugal duct fan, three-phase AC

EPK..B - Centrifugal channel fan, AC

Potentiometer

SW - Setpoint generator 0°C to 30°C

Min - minimum limit for the supply air temperature

Max - maximum limit for the supply air temperature

CT - Cycle time 6 - 120 seconds

Coding switch

1 - Up (On) = Internal setpoint generator

1 - Down (Off) = External setpoint generator

2 - On/Off = Minimum limit On/Off

3 - On/Off = Maximum limit On/Off

The minimum and maximum limits can be activated separately or together.

  1. FL 30 P channel sensor, setpoint generator in the DTL 24P
  2. Room sensor and setpoint generator in the FR 30 P
  3. FL 30 P channel sensor, setpoint generator in the FR 30 P
  4. FL 30 P supply air channel sensor for minimum and maximum limits
  5. Remove bridge J1


DTL 24 P combined with EPK / DPK channel fan and DHP .. - 28 electrical air heater

S1 - system off switch

S2 - system on switch

K1 - Fan on (US 16 contactor)

LW 9 - air flow monitor

DHP .. - Electrical air heater

F1 - temperature limiter

F2 - safety temperature limiter

K2 - heating release (K2 must be supplied by customer)

K3 - heating release (K3 must be supplied by customer)

DPK..B - Centrifugal duct fan, three-phase AC

EPK..B - Centrifugal channel fan, AC

Potentiometer

SW - Setpoint generator 0°C to 30°C

Min - minimum limit for the supply air temperature

Max - maximum limit for the supply air temperature

CT - Cycle time 6 - 120 seconds

Coding switch

1 - Up (On) = Internal setpoint generator

1 - Down (Off) = External setpoint generator

2 - On/Off = Minimum limit On/Off

3 - On/Off = Maximum limit On/Off

The minimum and maximum limits can be activated separately or together.

  1. FL 30 P channel sensor, setpoint generator in the DTL 24P
  2. Room sensor and setpoint generator in the FR 30 P
  3. FL 30 P channel sensor, setpoint generator in the FR 30 P
  4. FL 30 P supply air channel sensor for minimum and maximum limits
  5. Remove bridge J1


Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. OK

Acknowledgements Data protection