Temperature control system

ETL 16 P

No longer available for delivery
Article number: 0157.0824
Manufacturer: MAICO
Electronic temperature controller for controlling electric air heaters, 230 VAC/50 Hz, max. 16 A

Product data sheet
ETL 16 P IM0009805.PNG Electronic temperature controller for controlling electric air heaters, 230 VAC/50 Hz, max. 16 A

Characteristic curve

Dimensioned drawing

Technical data

ETL 16 P - Technical data

Article ETL 16 P
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz/60 Hz
Maximum load 16 A
Degree of protection IP 20
Type of installation Surface-mounted
Weight 0,2 kg
Weight including packaging 0,287 kg
Width 93 mm
Height 153 mm
Depth 40 mm
Width with packaging 95 mm
Height with packaging 165 mm
Depth with packaging 50 mm
Packing unit 1 piece
Range C
GTIN (EAN) 4012799578246
Article number 0157.0824

Accessories / Accessories of

ETL 16 P - Accessories / Accessories of

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Channel sensor FL 30 P 0157.0780 on request
  • On the notes
Room sensor FR 30 P 0157.0781 on request
  • On the notes

is a special accessory of

Product type Name Art. No. Price*(EUR) Action
Electrical air heater For ERH, DRH duct systems - - -

is a general accessory of

Product type Name Art. No. Price*(EUR) Action
Sound-insulated ventilation box ESR EC sound-insulated ventilation box - - -
Centrifugal duct fan ERR 10/1 0080.0270 on request
  • On the notes
Centrifugal duct fan ERR 10/1 S 0080.0271 on request
  • On the notes
Centrifugal duct fan ERR 12/1 0080.0272 on request
  • On the notes
Centrifugal duct fan ERR 16/1 0080.0273 on request
  • On the notes
Centrifugal duct fan ERR 16/1 S 0080.0274 on request
  • On the notes
Centrifugal duct fan ERR 20/1 0080.0275 on request
  • On the notes
Centrifugal duct fan ERR 25/1 0080.0277 on request
  • On the notes
Centrifugal duct fan ERR 31/1 0080.0278 on request
  • On the notes
Centrifugal duct fan ERR N centrifugal duct fan - - -
Aeronom room air system WS 170 - - -
Aeronom room air system WS 600 - - -
Centralised ventilation unit WS 160 Flat - - -
Centralised ventilation unit WS 170 air@home - - -
Centralised ventilation unit WS 300 Flat - - -
Centralised ventilation unit WS 320 - - -
Centralised ventilation unit WS 470 - - -
Sound-insulated ventilation box ESR -2 EC sound-insulated ventilation box - - -
Centralised ventilation unit WR 310 0095.0220 on request
  • On the notes
Centralised ventilation unit WR 310 R 0095.0260 on request
  • On the notes
Centralised ventilation unit WR 410 0095.0228 on request
  • On the notes
Centralised ventilation unit WR 410 R 0095.0261 on request
  • On the notes
Centralised ventilation unit WS 150 R Remaining parts 0095.0057 on request
  • On the notes
Centralised ventilation unit WS 150 L Remaining parts 0095.0058 on request
  • On the notes
Centrifugal duct fan ERR 20/1 S No longer available for delivery 0080.0276 on request
  • On the notes
Centrifugal duct fan ERR 31/1 S No longer available for delivery 0080.0279 on request
  • On the notes
Centralised ventilation unit WS 250 No longer available for delivery 0095.0050 on request
  • On the notes
Centralised ventilation unit WR 300 No longer available for delivery 0095.0078 on request
  • On the notes
Centralised ventilation unit WR 400 No longer available for delivery 0095.0079 on request
  • On the notes
Centralised ventilation unit WR 600 No longer available for delivery 0095.0080 on request
  • On the notes
Aeronom room air system WRG 300 EC No longer available for delivery 0082.0060 on request
  • On the notes
Centralised ventilation unit WRG 180 EC No longer available for delivery 0082.0059 on request
  • On the notes
Centralised ventilation unit WRG 300 EC No longer available for delivery 0082.0062 on request
  • On the notes
Centralised ventilation unit WRG 400 EC No longer available for delivery 0082.0063 on request
  • On the notes
Sound-insulated ventilation box ESR 12-2 No longer available for delivery 0080.0610 on request
  • On the notes
Sound-insulated ventilation box ESR 16-2 No longer available for delivery 0080.0611 on request
  • On the notes
Sound-insulated ventilation box ESR 20-2 No longer available for delivery 0080.0612 on request
  • On the notes
Sound-insulated ventilation box ESR 25-2 No longer available for delivery 0080.0613 on request
  • On the notes
Sound-insulated ventilation box ESR 31-2 No longer available for delivery 0080.0614 on request
  • On the notes
Sound-insulated ventilation box ESR 12-2 No longer available for delivery 0080.0056 on request
  • On the notes
Sound-insulated ventilation box ESR 16-2 No longer available for delivery 0080.0057 on request
  • On the notes
Sound-insulated ventilation box ESR 20-2 No longer available for delivery 0080.0058 on request
  • On the notes
Sound-insulated ventilation box ESR 25-2 No longer available for delivery 0080.0059 on request
  • On the notes
Sound-insulated ventilation box ESR 31-2 No longer available for delivery 0080.0060 on request
  • On the notes
Sound-insulated ventilation box ESR 12-2 S No longer available for delivery 0080.0617 on request
  • On the notes
Sound-insulated ventilation box ESR 16-2 S No longer available for delivery 0080.0618 on request
  • On the notes
Sound-insulated ventilation box ESR 20-2 S No longer available for delivery 0080.0619 on request
  • On the notes
Sound-insulated ventilation box ESR 25-2 S No longer available for delivery 0080.0620 on request
  • On the notes
Sound-insulated ventilation box ESR 31-2 S No longer available for delivery 0080.0621 on request
  • On the notes
Quickbox ESQ 25/4 No longer available for delivery 0080.0027 on request
  • On the notes
Quickbox DSQ 25/4 No longer available for delivery 0080.0032 on request
  • On the notes
Quickbox ESQ 31/4 No longer available for delivery 0080.0028 on request
  • On the notes
Quickbox DSQ 31/4 No longer available for delivery 0080.0033 on request
  • On the notes
Quickbox ESQ 25/4 K No longer available for delivery 0080.0069 on request
  • On the notes
Quickbox DSQ 25/4 K No longer available for delivery 0080.0074 on request
  • On the notes
Quickbox ESQ 31/4 K No longer available for delivery 0080.0070 on request
  • On the notes
Quickbox DSQ 31/4 K No longer available for delivery 0080.0075 on request
  • On the notes

Product description

Productdescription

ETL 16 P

short description

Electronic temperature controller for controlling electric air heaters, 230 VAC/50 Hz, max. 16 A

Product description

  • Electronic temperature controller for controlling the ERH, DRH electrical air heaters.
  • With integrated sensor for measuring the room temperature.
  • Optional control of supply air temperature or room temperature.
  • Triac regulator with pulse packet control.
  • Pulse period: 60 s.
  • Night reduction can be set from 0 K to 10 K below the setpoint temperature.
  • DTL 16 P: With additional input for setting minimum or maximum supply air temperatures. Possible only in combination with FL 30 P channel sensor.
  • Accessories: FL 30 P channel sensor for measuring the air temperature in ventilation channels; FR 30 P room sensor for measurements in enclosed areas.

Table of contents

Wiring diagram

ETL 16 P - Wiring diagram

ETL 16 P temperature control system with ERH... electric air heater and LW 9 air flow monitor

1 - external channel sensor and internal setpoint generator in ETL 16 P

2 - external room sensor and external setpoint generator

3 - external channel sensor and external setpoint generator

4 - internal room sensor and internal setpoint generator in ETL 16 P

5 - 0...10 K setting for night reduction

S1 - system on

K1 - heating release (US16)

LW 9 - air flow monitor

FL 30 P - channel sensor

FR 30 P - room sensor

ERH.. - electric air heater

F1 - temperature limiter

F2 - safety temperature limiter

S - sensor

SW- setpoint

N - night reduction



ERH... electric air heater with LW 9 air flow monitor and ST speed controller

K1 - heating release (US16T)

ERR .. / 1 - centrifugal fan

LW 9 - air flow monitor

ETL 16 P - electronic temperature controller

DTL 16 P - electronic temperature controller

FL 30P channel sensor

ST.. STU.., STS.. speed controller

ERH - electric air heater

F1 - temperature limiter

F2 - safety temperature limiter

N - night reduction

  1. Only with DTL 16 P


ETL 16 P temperature control system with DRH... electric air heater and LW 9 air flow monitor

1 - external channel sensor and internal setpoint generator in ETL 16 P

2 - external room sensor and external setpoint generator

3 - external channel sensor and external setpoint generator

4 - internal room sensor and internal setpoint generator in ETL 16 P

5 - 0...10K setting for night reduction

S1 - system on

K1 - heating release (US16)

LW 9 - air flow monitor

FL 30 P - channel sensor

FR 30 P - room sensor

DRH... - electric air heater

F1 - temperature limiter

F2 - safety temperature limiter

S - sensor

SW- setpoint

N - night reduction



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings