Temperature control system

ETL 16 P

No longer available for delivery
Article number: 0157.0824
Manufacturer: MAICO
Electronic temperature controller for controlling electric air heaters, 230 VAC/50 Hz, max. 16 A
ETL 16 P IM0009805.PNG Electronic temperature controller for controlling electric air heaters, 230 VAC/50 Hz, max. 16 A

Characteristic curve

Dimensioned drawing

Technical data

ETL 16 P - Technical data

Article ETL 16 P
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz/60 Hz
Maximum load 16 A
Degree of protection IP 20
Type of installation Surface-mounted
Weight 0,2 kg
Width 93 mm
Height 153 mm
Depth 40 mm
Packing unit 1 piece
Range C
GTIN (EAN) 4012799578246
Article number 0157.0824

Accessories / Accessories of

ETL 16 P - Accessories / Accessories of

Specific accessories

Product typeNameArt. No.Price*(EUR)Action
Channel sensorFL 30 P0157.0780 on request
  • On the notes
Room sensorFR 30 P0157.0781 on request
  • On the notes

is a special accessory of

Product typeNameArt. No.Price*(EUR)Action
Electrical air heaterFor ERH, DRH duct systems---

is a general accessory of

Product typeNameArt. No.Price*(EUR)Action
Sound-insulated ventilation boxESR -2 EC sound-insulated ventilation box---
Sound-insulated ventilation boxESR EC sound-insulated ventilation box---
Centrifugal duct fanERR 10/10080.0270 on request
  • On the notes
Centrifugal duct fanERR 10/1 S0080.0271 on request
  • On the notes
Centrifugal duct fanERR 12/10080.0272 on request
  • On the notes
Centrifugal duct fanERR 16/10080.0273 on request
  • On the notes
Centrifugal duct fanERR 16/1 S0080.0274 on request
  • On the notes
Centrifugal duct fanERR 20/10080.0275 on request
  • On the notes
Centrifugal duct fanERR 25/10080.0277 on request
  • On the notes
Centrifugal duct fanERR 31/10080.0278 on request
  • On the notes
Centrifugal duct fanERR N centrifugal duct fan---
ESR EC sound-insulated ventilation box----
Aeronom room air systemWS 170---
Aeronom room air systemWS 600---
Centralised ventilation unitWS 160 Flat---
Centralised ventilation unitWS 170 / WS 170 ET---
Centralised ventilation unitWS 170 air@home---
Centralised ventilation unitWS 300 Flat---
Centralised ventilation unitWS 320---
Centralised ventilation unitWS 470---
Centrifugal duct fanERR 20/1 SNo longer available for delivery0080.0276 on request
  • On the notes
Centrifugal duct fanERR 31/1 SNo longer available for delivery0080.0279 on request
  • On the notes
Centralised ventilation unitWS 150 RDiscontinued product0095.0057 on request
  • On the notes
Centralised ventilation unitWS 150 LDiscontinued product0095.0058 on request
  • On the notes
Centralised ventilation unitWR 3100095.0220 on request
  • On the notes
Centralised ventilation unitWR 310 RNew development0095.0260 on request
  • On the notes
Centralised ventilation unitWR 4100095.0228 on request
  • On the notes
Centralised ventilation unitWR 410 RNew development0095.0261 on request
  • On the notes
QuickboxDSQ 31/4 KNo longer available for delivery0080.0075 on request
  • On the notes
Centralised ventilation unitWS 250No longer available for delivery0095.0050 on request
  • On the notes
Centralised ventilation unitWR 300No longer available for delivery0095.0078 on request
  • On the notes
Centralised ventilation unitWR 400No longer available for delivery0095.0079 on request
  • On the notes
Centralised ventilation unitWR 600No longer available for delivery0095.0080 on request
  • On the notes
Aeronom room air systemWRG 300 ECNo longer available for delivery0082.0060 on request
  • On the notes
Centralised ventilation unitWRG 180 ECNo longer available for delivery0082.0059 on request
  • On the notes
Centralised ventilation unitWRG 300 ECNo longer available for delivery0082.0062 on request
  • On the notes
Centralised ventilation unitWRG 400 ECNo longer available for delivery0082.0063 on request
  • On the notes
Sound-insulated ventilation boxESR 12-2No longer available for delivery0080.0610 on request
  • On the notes
Sound-insulated ventilation boxESR 16-2No longer available for delivery0080.0611 on request
  • On the notes
Sound-insulated ventilation boxESR 20-2No longer available for delivery0080.0612 on request
  • On the notes
Sound-insulated ventilation boxESR 25-2No longer available for delivery0080.0613 on request
  • On the notes
Sound-insulated ventilation boxESR 31-2No longer available for delivery0080.0614 on request
  • On the notes
Sound-insulated ventilation boxESR 12-2No longer available for delivery0080.0056 on request
  • On the notes
Sound-insulated ventilation boxESR 16-2No longer available for delivery0080.0057 on request
  • On the notes
Sound-insulated ventilation boxESR 20-2No longer available for delivery0080.0058 on request
  • On the notes
Sound-insulated ventilation boxESR 25-2No longer available for delivery0080.0059 on request
  • On the notes
Sound-insulated ventilation boxESR 31-2No longer available for delivery0080.0060 on request
  • On the notes
Sound-insulated ventilation boxESR 12-2 SNo longer available for delivery0080.0617 on request
  • On the notes
Sound-insulated ventilation boxESR 16-2 SNo longer available for delivery0080.0618 on request
  • On the notes
Sound-insulated ventilation boxESR 20-2 SNo longer available for delivery0080.0619 on request
  • On the notes
Sound-insulated ventilation boxESR 25-2 SNo longer available for delivery0080.0620 on request
  • On the notes
Sound-insulated ventilation boxESR 31-2 SNo longer available for delivery0080.0621 on request
  • On the notes
QuickboxESQ 25/4No longer available for delivery0080.0027 on request
  • On the notes
QuickboxDSQ 25/4No longer available for delivery0080.0032 on request
  • On the notes
QuickboxESQ 31/4No longer available for delivery0080.0028 on request
  • On the notes
QuickboxDSQ 31/4No longer available for delivery0080.0033 on request
  • On the notes
QuickboxESQ 25/4 KNo longer available for delivery0080.0069 on request
  • On the notes
QuickboxDSQ 25/4 KNo longer available for delivery0080.0074 on request
  • On the notes
QuickboxESQ 31/4 KNo longer available for delivery0080.0070 on request
  • On the notes

Product description

Productdescription

ETL 16 P

short description

Electronic temperature controller for controlling electric air heaters, 230 VAC/50 Hz, max. 16 A

Product description

  • Electronic temperature controller for controlling the ERH, DRH electrical air heaters.
  • With integrated sensor for measuring the room temperature.
  • Optional control of supply air temperature or room temperature.
  • Triac regulator with pulse packet control.
  • Pulse period: 60 s.
  • Night reduction can be set from 0 K to 10 K below the setpoint temperature.
  • DTL 16 P: With additional input for setting minimum or maximum supply air temperatures. Possible only in combination with FL 30 P channel sensor.
  • Accessories: FL 30 P channel sensor for measuring the air temperature in ventilation channels; FR 30 P room sensor for measurements in enclosed areas.

Table of contents

Wiring diagram

ETL 16 P - Wiring diagram

ETL 16 P temperature control system with ERH... electric air heater and LW 9 air flow monitor

1 - external channel sensor and internal setpoint generator in ETL 16 P

2 - external room sensor and external setpoint generator

3 - external channel sensor and external setpoint generator

4 - internal room sensor and internal setpoint generator in ETL 16 P

5 - 0...10 K setting for night reduction

S1 - system on

K1 - heating release (US16)

LW 9 - air flow monitor

FL 30 P - channel sensor

FR 30 P - room sensor

ERH.. - electric air heater

F1 - temperature limiter

F2 - safety temperature limiter

S - sensor

SW- setpoint

N - night reduction



ERH... electric air heater with LW 9 air flow monitor and ST speed controller

K1 - heating release (US16T)

ERR .. / 1 - centrifugal fan

LW 9 - air flow monitor

ETL 16 P - electronic temperature controller

DTL 16 P - electronic temperature controller

FL 30P channel sensor

ST.. STU.., STS.. speed controller

ERH - electric air heater

F1 - temperature limiter

F2 - safety temperature limiter

N - night reduction

  1. Only with DTL 16 P


ETL 16 P temperature control system with DRH... electric air heater and LW 9 air flow monitor

1 - external channel sensor and internal setpoint generator in ETL 16 P

2 - external room sensor and external setpoint generator

3 - external channel sensor and external setpoint generator

4 - internal room sensor and internal setpoint generator in ETL 16 P

5 - 0...10K setting for night reduction

S1 - system on

K1 - heating release (US16)

LW 9 - air flow monitor

FL 30 P - channel sensor

FR 30 P - room sensor

DRH... - electric air heater

F1 - temperature limiter

F2 - safety temperature limiter

S - sensor

SW- setpoint

N - night reduction



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. Agreed

Acknowledgements Data protection