Axial duct fan

DZR 35/6 B

Article number: 0086.0026
Manufacturer: MAICO
Axial duct fan, DN 350, three-phase AC
Application examples: Machine extraction unit, Showroom, Foreman's office, Workshop, Production site
DZR 35/6 B IM0009987.PNG Axial duct fan, DN 350, three-phase AC

Characteristic curve

DZR 35/6 B - Characteristic curve

  • DZR 35/6 B IM0002777.PNG Axial duct fan, DN 350, three-phase AC

Dimensioned drawing

DZR 35/6 B - Dimensioned drawing [mm]

  • DZR 35/6 B IM0001714.PNG Axial duct fan, DN 350, three-phase AC

Number of flange holes: 8

Technical data

DZR 35/6 B - Technical data

Article DZR 35/6 B
Air flow volume 1.800 m³/h
Rotating speed 930 1/min
Impeller type axial
Speed controllable
Reversing capacity
Type of voltage Three-phase AC
Rated voltage 400 V
Frequency 50 Hz
Nominal output 75 W
Inom 0,17 A
Imax 0,17 A
Degree of protection IP 55
Insulation class B
Pole-changeable
Mains cable 7 x 1,5 mm²
Installation position horizontal / vertical
Material Sheet steel, galvanised
Weight 9,6 kg
Nominal size 350 mm
Width 420 mm
Height 474 mm
Depth 320 mm
Airstream temperature at nominal current -20 °C up to 60 °C
Airstream temperature at IMax -20 °C up to 60 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799860266
Article number 0086.0026

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, S1 (dB(A))

17

15

13

15

16

11

12

10

23

LWA2, S2 (dB(A))

19

26

30

26

27

22

16

13

34

LWA2, S3 (dB(A))

28

32

36

33

34

29

23

16

41

LWA2, S4 (dB(A))

19

41

41

39

40

36

30

19

47

LWA2, S5 (dB(A))

21

39

39

47

43

40

35

22

50

LWA5, S1 (dB(A))

13

23

26

20

18

14

8

9

29

LWA5, S2 (dB(A))

25

30

46

35

36

34

27

25

47

LWA5, S3 (dB(A))

23

41

58

42

44

43

33

21

54

LWA5, S4 (dB(A))

23

39

54

47

48

49

40

26

57

LWA5, S5 (dB(A))

25

41

54

56

52

53

44

31

60

LWA6, S1 (dB(A))

17

21

23

27

24

18

9

8

31

LWA6, S2 (dB(A))

28

32

37

42

41

38

25

13

46

LWA6, S3 (dB(A))

31

41

47

49

49

48

37

22

55

LWA6, S4 (dB(A))

31

46

53

55

56

56

55

52

63

LWA6, S5 (dB(A))

34

48

54

61

62

62

63

61

69

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

Accessories

DZR 35/6 B - Accessories

General accessories

Product typeNameArt. No.Price*(EUR)Action
ShutterAS 350151.0333 on request
  • On the notes
Shutter, manualRS 350151.0341 on request
  • On the notes
ServomotorMS 20093.0403 on request
  • On the notes
Control shutterJRE 350151.0392 on request
  • On the notes
ServomotorMS 80157.0760 on request
  • On the notes
ServomotorMS 8 P0157.0761 on request
  • On the notes
Internal grilleIG 350059.0174 on request
  • On the notes
Protective grille, metalSG 350150.0117 on request
  • On the notes
Protective grille, synthetic materialSGK 350059.0164 on request
  • On the notes
Flexible couplingELA 350092.0268 on request
  • On the notes
Flexible cuffEL 350092.0090 on request
  • On the notes
Counter flangeGF 350056.0005 on request
  • On the notes
Counter socketGS 350055.0171 on request
  • On the notes
Suction nozzleAD 350180.0622 on request
  • On the notes
Mounting footFU 350036.0072 on request
  • On the notes
Vibration damperGP 100092.0151 on request
  • On the notes
Main switch, service switchHS 30157.0736 on request
  • On the notes
Rotary switchDS 100157.0410 on request
  • On the notes
Reversing switchW 10157.0101 on request
  • On the notes
Reversing switchWU 10157.0102 on request
  • On the notes
Motor protection switchMV 250157.0712 on request
  • On the notes
ContactorUS 16 T0157.0769 on request
  • On the notes
5-step transformerTR 0,4-20157.0147 on request
  • On the notes
5-step transformer, control cabinetTR 0,8 S-20157.0151 on request
  • On the notes
5-step switch for TRE...S -2/ TR...S-2 5-step transformersDSS 200157.0750 on request
  • On the notes
ThermostatTHR 100157.0774 on request
  • On the notes
ThermostatTH 100157.0764 on request
  • On the notes
ThermostatTH 160157.0748 on request
  • On the notes
Air flow monitorLW 90157.0779 on request
  • On the notes
HygrostatHY 2300157.0126 on request
  • On the notes
HygrostatHY 230 I0157.0127 on request
  • On the notes
HygrostatHY 10 APNo longer available for delivery0157.0358 on request
  • On the notes
HygrostatHY 10 UPNo longer available for delivery0157.0357 on request
  • On the notes
Air quality controllerEAQ 10/10157.0777 on request
  • On the notes
Mounting and sealing materialBD 35No longer available for delivery0092.0135 on request
  • On the notes

Product description

Productdescription

DZR 35/6 B

short description

Axial duct fan, DN 350, three-phase AC

Product description

Features

  • Duct sleeve made of galvanised sheet steel, with flanges on both sides.
  • 8-blade impellers made of glass-fibre filled polyamide. Dynamically balanced at two levels, in accordance with performance level 6.3, DIN ISO 1940, Part 1.
  • Flange holes in accordance with DIN EN 12220:1998.
  • DZR 56/6 B and DZR 56/4 B: Flange holes in accordance with DIN EN 12220:1998.
  • To avoid transmission of vibrations to the duct system: Use flexible couplings, feet and vibration dampers.
  • High degree of protection IP 55. Exception EZR/DZR... D IP 54.
  • Can be fitted in any position.

Motor

  • Asynchronous motor, speed controllable. Exception: Type DZR 40/2 B.
  • Not suitable for ventilating steam-saturated air.
  • Air flow direction is indicated on the unit with direction of rotation and air flow direction arrows.
  • Reversing mode: The volumetric flow is reduced by approx. 35 % with abnormal air flow direction.

Three-phase AC motor

  • DZR model series.
  • Rated voltage 400 V, 50 Hz.
  • Thermal overload protection as a standard feature. Exception: available on request for DZR 25/4 D and pole-changeable axial duct fans. Potential-free terminal connections, which must be connected to e.g. an MV 25 protective motor switch or the control circuit of a contactor.
  • Pole-changeable fans: Ensure overload protection is guaranteed by a motor protection switch provided by the customer.

Electrical connection

  • Terminal box with cable sleeves fitted on the outside.

Safety instructions

  • The fan may be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN 13857.

Special versions

  • The following special versions are available on request, at an extra cost:
    • Special voltages and frequencies.
    • PTC thermistor, potential-free terminal connection.
    • Condensation drainage holes.
    • Fans with enhanced anti-corrosion protection.
    • Impellers made of aluminium.
  • Information on operation at temperatures occasionally below -20°C available upon request.
  • If operating with frequency converters, the factory must be consulted.
  • Feasibility must be checked in each case.

Table of contents

Wiring diagram

DZR 35/6 B - Wiring diagram











Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. Agreed

Acknowledgements Data protection