Fan insert

ER 60 EH

For export only!
Article number: 0084.0375
Manufacturer: MAICO
Fan insert with cover and filter for installation in ER-UP/GH recessed-mounted housing, air volume 35 / 61... more information
Application examples: Bathroom, Kitchen, Multiple family unit, Day room, Dining room
ER 60 EH IM0018450.PNG Fan insert with cover and filter for installation in ER-UP/GH recessed-mounted housing, air volume 35 / 61 m³/h, with humidity control and base load circuit
ER 60 EH IM0008446.PNG Fan insert with cover and filter for installation in ER-UP/GH recessed-mounted housing, air volume 35 / 61 m³/h, with humidity control and base load circuit

Characteristic curve

ER 60 EH - Characteristic curve

  • ER 60 EH IM0018429.PNG Fan insert with cover and filter for installation in ER-UP/GH recessed-mounted housing, air volume 35 / 61 m³/h, with humidity control and base load circuit

Dimensioned drawing

ER 60 EH - Dimensioned drawing [mm]

  • ER 60 EH IM0018435.PNG Fan insert with cover and filter for installation in ER-UP/GH recessed-mounted housing, air volume 35 / 61 m³/h, with humidity control and base load circuit

Fan insert ER ... E with ER-UP/GH recess-mounted housing

ER 60 EH - Dimensioned drawing [mm]

  • ER 60 EH IM0018436.PNG Fan insert with cover and filter for installation in ER-UP/GH recessed-mounted housing, air volume 35 / 61 m³/h, with humidity control and base load circuit

Fan insert ER ... E with ER-UP/GH recess-mounted housing and second room connection

Technical data

ER 60 EH - Technical data

Article ER 60 EH
Model Humidity control
Air flow volume 35 m³/h / 61 m³/h
Rotating speed 900 1/min / 1.250 1/min
Air direction Air extraction
Speed controllable
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Power consumption 11 W / 21 W
Imax 0,13 A / 0,17 A
Degree of protection IP X5
Mains cable 5 x 1,5 mm²
Installation site Wall / Ceiling
Type of installation Recessed-mounted
System type Decentralised
Material Synthetic material
Colour Traffic white, similar to RAL 9016
Filter class G3
Air outlet direction at rear
Airstream temperature at IMax 40 °C
Sound pressure level 33 dB(A) / 40 dB(A) / Specifications in accordance with DIN 18017-3 at an equivalent absorption area AL = 10 m.2
Article number 0084.0375

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA7, low (dB(A))

37

LWA7, high (dB(A))

43

LWA7= housing and free inlet sound power level in dB.

Accessories / Accessories of

ER 60 EH - Accessories / Accessories of

Specific accessories

Product typeNameArt. No.Price*(EUR)Action
Recessed-mounted housingER-UP/GHFor export only!0084.0370 on request
  • On the notes
Air filter, replacementZF 60/100New development0093.0331 on request
  • On the notes
Air filter, replacementZF 60/100No longer available for delivery0093.0680 on request
  • On the notes
Air filter, replacementZF 60/100 bulk container0093.0885 on request
  • On the notes
Masking frameER-AR0059.0899 on request
  • On the notes
Spacing frameDR 60/1000059.0928 on request
  • On the notes

General accessories

Product typeNameArt. No.Price*(EUR)Action
Flexible aluminium ductAFR---
Roof outletDF---
Roofing tileDP---
Mounting clampBS---
Rain protection grilleRG---
Outside air openingALD 100152.0054 on request
  • On the notes
Outside air openingALD 1250152.0067 on request
  • On the notes
Outside air openingALD 125 VA0152.0068 on request
  • On the notes
Outside air openingALD 1600152.0069 on request
  • On the notes
Outside air openingALD 160 VA0152.0070 on request
  • On the notes
Door ventilation grilleMLK 30 white0151.0123 on request
  • On the notes
Door ventilation grilleMLK 45 white0151.0126 on request
  • On the notes
Radio switchXS 10157.0344 on request
  • On the notes
Radio receiverXE 10157.0343 on request
  • On the notes

is a special accessory of

Product typeNameArt. No.Price*(EUR)Action
Recessed-mounted housingRecess-mounted housing ER-UP/GH---

Product description

Productdescription

ER 60 EH

short description

Fan insert with cover and filter for installation in ER-UP/GH recessed-mounted housing, air volume 35 / 61 m³/h, with humidity control and base load circuit

Product description

Model with humidity control and base load circuit

  • Barrier-free product as the fan switches itself on and off automatically.
  • Switch-on humidity does not have to be set. Fan monitors the room humidity.
  • Automatically vents in full load depending on room humidity.
  • Not speed-controllable.
  • Not suitable for second room ventilation.
  • Can be operated manually via a switch, e.g. full load is switched on using a light switch.
  • Standard switching: Fan runs in base load operation, humidity control is active, full load operation when the switch-on point is exceeded, base load operation when humidity falls below switch-off point.
  • More switching variants: Fan operation with or without base load operation; manual activation of full load; the fan is switched on/off using a switch.
  • Activation of full load using light switch and a fan overrun control linked to this (15 minute overrun time).
  • After 60 min. in humidity mode, the fan automatically switches off (or into base load) and resets the reference value for the switch-on point.

Features

  • Fan with cover and G2 filter for installation in ER-UP/GH recessed-mounted housing.
  • For single or second room air extraction using a single fan (exception: model ER ... EH).
  • Electrical plug connection for quick fan installation in the housing.
  • Trouble-free filter change without using tools.
  • It is possible to rotate the cover by ± 5°, to compensate for housings which have been fitted at an angle.
  • The housing has easy to install snap-in fan fittings.
  • Colour: traffic white, similar to RAL 9016.
  • All MAICO ER units have an IP X5 degree of protection and can be installed in area 1 in accordance with DIN VDE 0100-701, even with water jets. For details see planning instructions.
  • Protection class II.
  • The extremely steep characteristic curve shows the high pressure capacity of the ER fans.
  • Robust energy saving capacitor motor.
  • Motor with thermal overload protection.
  • Maintenance-free, with enclosed ball bearings on both sides.
  • Volumetric flow characteristic curve and air leakage rate checked by TÜV Bayern e.V (German Technical Inspection Agency). Air leakage rate < 0.01 m³/h.

Table of contents

Wiring diagram

ER 60 EH - Wiring diagram

Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. Agreed

Acknowledgements Data protection