Final assembly kit

PP 45 K

Article number: 0095.0241
Manufacturer: MAICO
Final assembly kit for PushPull 45 K single-room ventilation unit with heat recovery, comprising fan, ceramic... more information
PP 45 K IM0017236.PNG Final assembly kit for PushPull 45 K single-room ventilation unit with heat recovery, comprising fan, ceramic heat exchanger, internal cover with shutter drive and 1 x G2 and 1 x G3 filter, version: with electric shutter, accessories needed: shell sleeve, external cover or soffit element and RLS 45 K or RLS 45 O room air control, optional accessories: wall block, sensors, power unit and EnOcean extension module

Characteristic curve

Dimensioned drawing

PP 45 K - Dimensioned drawing [mm]

  • PP 45 K IM0017170.PNG Final assembly kit for PushPull 45 K single-room ventilation unit with heat recovery, comprising fan, ceramic heat exchanger, internal cover with shutter drive and 1 x G2 and 1 x G3 filter, version: with electric shutter, accessories needed: shell sleeve, external cover or soffit element and RLS 45 K or RLS 45 O room air control, optional accessories: wall block, sensors, power unit and EnOcean extension module
  1. Cable feedthrough

Technical data

PP 45 K - Technical data

Article PP 45 K
Air flow volume 15 m³/h / 20 m³/h / 30 m³/h / 36 m³/h / 42 m³/h
Energy efficiency class A+
Rated voltage 12 V DC
SPI value in accordance with DIN EN 13141-8 0,11 Wh/m³
Maximum power consumption 1,2 W / 1,7 W / 2,1 W / 2,8 W / 3,5 W
Degree of protection IP 00
DIBT approval yes
Installation position horizontal
System type Decentralised
Housing material Synthetic material
Heat exchanger material Ceramic
Colour Traffic white, similar to RAL 9016
Weight 3,14 kg
Type of filter Outside and exhaust air filter
Filter class G2 / G3
Connection diameter 160 mm
Width 246 mm
Height 246 mm
Depth 329 mm
Wall has to be broken through 162 to 182 mm
Wall thickness 265 mm (if the slide-in module is flush with the wall sleeve) / 500 mm
Degree of heat provision with reference volumetric flow according to DIN EN 13141-8 84,3 %
Required room air control RLS 45 K / RLS 45 O
Sound pressure level 21 dB(A) / 25 dB(A) / 31 dB(A) / 35 dB(A) / 38 dB(A) / Distance 1 m, free-field conditions
Rated max. element normal difference in noise level Dn,w 51 dB
Approval number Z-51.3-416
Packing unit 1 piece
Range K
GTIN (EAN) 4012799952411
Article number 0095.0241

Product description

Productdescription

PP 45 K

short description

Final assembly kit for PushPull 45 K single-room ventilation unit with heat recovery, comprising fan, ceramic heat exchanger, internal cover with shutter drive and 1 x G2 and 1 x G3 filter, version: with electric shutter, accessories needed: shell sleeve, external cover or soffit element and RLS 45 K or RLS 45 O room air control, optional accessories: wall block, sensors, power unit and EnOcean extension module

Product description

Features

  • Final assembly kits for PushPull 45 single-room ventilation unit with fan, ceramic heat exchanger, internal cover and two integrated filters (G2 + G3) such that the air is filtered in both directions.
  • Models:
    • PP 45 K - with electric shutter.
    • PP 45 O - with manual shutter.
    • PP 45 RC - with radio control and electric shutter.
  • To achieve efficient ventilation, we would recommend operating the units in pairs. This is a basic requirement for the PP 45 RC final assembly kit.
  • Accessories needed:
    • PP 45 RHK or PP 45 RHL shell sleeve
    • PP 45 AK, PP 45 AE or PP 45 AW external cover for external wall mounting or PP 45 LE soffit element for soffit channel mounting
    • RLS 45 K or RLS 45 O room air control for the PP 45 K and PP 45 O final assembly kits and DS 45 RC radio switch for the PP 45 RC radio unit
    • Up to a maximum of 6 units can be controlled at the same time through an RLS 45 K or RLS 45 O room air control.
    • If using the DS 45 RC radio switch, there is no limit on the number of units provided that they are within range of the radio switches.
  • Optional accessories:
    • Wall block PP 45 MB
    • PP 45 LT power unit
    • PP 45 EO EnOcean extension module
    • PP 45 ACT EnOcean actuator
    • PP 45 HYI and PP 45 HY humidity sensor
    • PP 45 CO2 CO2 sensor
    • PP 45 VOC VOC sensor
    • Air filter, PP 45 G2, PP 45 G3 and PP 45 G2P replacement
  • The PP 45 K and PP 45 RC unit versions have an electric shutter. If the units are switched off (level 0), the shutter closes automatically. The unit does not consume electricity in the process.
  • With the PP 45 O final assembly kit, the shutter is closed manually.
  • The PP 45 HYI internal humidity sensor or the PP45 HY, PP 45 CO2 and PP 45 VOC external sensors can be added to the RLS 45 K and RLS 45 O room air controls. The units therefore attain the A+ energy efficiency class.
  • The PP 45 RC final assembly kit can be extended with a PP45 HYI humidity sensor. The sensor is only installed in the master unit.
  • The RLS 45 K and RLS 45 O room air controls and the PP 45 RC radio units with the DS 45 RC radio switch can be operated in 5 ventilation levels of 15/20/30/36/42 m³/h and 3 operating programs (continuous ventilation with heat recovery, cross-ventilation and sensor-controlled automatic mode). In automatic mode, the air volume is continuously adapted to the sensor value.
  • With the RLS 45 O room air control, automatic mode is only possible with the connected sensor.
  • The RLS 45 K room air control and DS 45 RC radio switch can also perform other functions, such as intermittent ventilation (time-limited intensive ventilation) and sleep function (time-limited shutdown).
  • Using the RLS 45 K room air control, exhaust air units (e.g. ECA/ER) can communicate with PushPull units and vice versa. In other words, when an exhaust fan starts up, the PushPull units go into supply air mode to compensate for the partial vacuum produced. Supply air mode is possible with an overrun time of 0.6 or 15 min. The number of connected units is also taken into account.
  • When combined with the PP 45 EO EnOcean extension module, the RLS 45 K room air control provides the unique opportunity of linking the wired PP 45 K and PP 45 O units and PP 45 RC radio units with one another. This control combination can therefore be used to install wired units on the ground floor and radio units on the first floor. The entire system is activated at the touch of a button.
  • What’s more, the RLS 45 K room air control allows the unit to be easily configured using installation software on a PC/laptop (Windows).

Heat exchanger

  • Thanks to the high-performance heat exchanger and high-efficiency EC fan, the units achieve a degree of heat provision of 84.3 % at reference volumetric flow according to EN 13141-8.

Mounting information

  • Mounting involves 2 steps:
    • Installation of the PP 45 RHK (DN 160) or RHL (DN 160) shell sleeve and an external cover in a DN 160 core drill hole with an inclination of 1-2 %.
    • We recommend drilling a DN 182 core hole and using the polystyrene shims provided to align the inclination of the sleeve.
    • The shell sleeve is protected from contamination by plaster protective covers.
    • Then the final assembly kit is integrated.
    • No ducts have to be laid and the system does not have to be adjusted.

Electrical connection

  • When delivered, the unit is assembled and ready for service.
  • The electrical supply is connected using a plug connection.
  • Connection to RLS 45 K or RLS 45 O room air control using pluggable control cables.
  • The 12 VDC power cable of the RLS 45 K / RLS 45 O room air control to the unit is also the control cable.

Condensation drain

  • The condensate is removed via an integrated condensation drop catcher in the external cover.

Table of contents

Wiring diagram

PP 45 K - Wiring diagram

RLS 45 K - PushPull 45 comfort room air control

PP 45 K - PushPull 45 comfort fan unit

Fan 1.1 - fan unit 1, unit pair 1

Fan 2.1 - fan unit 2, unit pair 1

Fan 1.2 - fan unit 1, unit pair 2

Fan 2.2 - fan unit 2, unit pair 2

Fan 1.3 - fan unit 1, unit pair 3

Fan 2.3 - fan unit 2, unit pair 3

S1 - Button/switch for additional function (sleep, intensive, disbalance, safety function)

UP-L -Recessed-mounted distributor connection for fan units, connection of all fan units in star shape to distributor

W-F1 - Fan 1 control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. length to distributor 4m.

W-F2 - Fan 2 control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. length to distributor 4m.

W1.X - Fan unit control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25m.

W2.X - Fan unit control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25m.

W3 - Bus (RS-485) connection cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. cable length to the sensors, RLS, LT and EnOcean module approx. 100m. Alternatively, this connection can also be used as a ModBus RTU interface.



PP 45 K - ventilation unit PP 45 K

VAP 45 - fan connection board PP 45 K



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. Agreed

Acknowledgements Data protection