Electrical air heater

DRH 16-5

Article number: 0082.0105
Manufacturer: MAICO
Electrical air heater, DN 160, 3-phase current
DRH 16-5 IM0009886.PNG Electrical air heater, DN 160, 3-phase current

Characteristic curve

DRH 16-5 - Characteristic curve Pressure losses

  • DRH 16-5 IM0001081.PNG Electrical air heater, DN 160, 3-phase current
  1. DRH 16-5
  2. ERH 12-1
  3. ERH 16-2
  4. ERH 10-04
  5. DRH 20-5
  6. DRH 25-6
  7. ERH 20-2
  8. DRH 25-2
  9. DRH 31-6

DRH 16-5 - Characteristic curve Temperature rise

  • DRH 16-5 IM0001082.PNG Electrical air heater, DN 160, 3-phase current
  1. ERH 10-4
  2. ERH 12-1
  3. ERH 16-2, ERH 20-2, ERH 25-2
  4. DRH 16-5, DRH 20-5
  5. DRH 25-6, DRH 31-6

Dimensioned drawing

DRH 16-5 - Dimensioned drawing [mm]

  • DRH 16-5 IM0001083.PNG Electrical air heater, DN 160, 3-phase current
A: 160 mm

Technical data

DRH 16-5 - Technical data

Article DRH 16-5
Type of voltage Three-phase AC
Rated voltage 400 V
Frequency 50 Hz
Imax 12,5 A
Degree of protection IP 43
Mains cable 5 x 1,5 mm²
Installation Inside
Installation position horizontal / vertical
Housing material Sheet steel, galvanised
Weight 3,9 kg
Nominal size 160 mm
Width 160 mm
Height 241 mm
Depth 375 mm
Air heater type electrical
Heater power rating 5.000 W
Packing unit 1 piece
Range C
GTIN (EAN) 4012799821052
Article number 0082.0105

Accessories / Accessories of

DRH 16-5 - Accessories / Accessories of

Specific accessories

Product typeNameArt. No.Price*(EUR)Action
Air filterTFE 16-40149.0077 on request
  • On the notes
Air filterTFE 16-50149.0061 on request
  • On the notes
Air filterTFE 16-70149.0052 on request
  • On the notes
Temperature control systemETL 16 PNo longer available for delivery0157.0824 on request
  • On the notes
Temperature control systemDTL 16 P0157.0825 on request
  • On the notes
Channel sensorFL 30 P0157.0780 on request
  • On the notes
Room sensorFR 30 P0157.0781 on request
  • On the notes
Air flow monitorLW 90157.0779 on request
  • On the notes

General accessories

Product typeNameArt. No.Price*(EUR)Action
ContactorUS 16 T0157.0769 on request
  • On the notes

is a special accessory of

Product typeNameArt. No.Price*(EUR)Action
Sound-insulated ventilation boxESR 16 SNo longer available for delivery0080.0228 on request
  • On the notes

is a general accessory of

Product typeNameArt. No.Price*(EUR)Action
Centrifugal duct fanERR 16/10080.0273 on request
  • On the notes
Centrifugal duct fanERR 16/1 S0080.0274 on request
  • On the notes
Sound-insulated ventilation boxESR 16-2 EC0080.0711 on request
  • On the notes
Sound-insulated ventilation boxESR 16 ECDiscontinued product0080.0085 on request
  • On the notes
Centrifugal duct fanERR 16/1 NNo longer available for delivery0080.0867 on request
  • On the notes
Sound-insulated ventilation boxESR 16/1No longer available for delivery0080.0282 on request
  • On the notes
Sound-insulated ventilation boxESR 16-2No longer available for delivery0080.0611 on request
  • On the notes
Sound-insulated ventilation boxESR 16-2No longer available for delivery0080.0057 on request
  • On the notes
Sound-insulated ventilation boxESR 16-2 SNo longer available for delivery0080.0618 on request
  • On the notes

Product description

Productdescription

DRH 16-5

short description

Electrical air heater, DN 160, 3-phase current

Product description

  • Electrical air heater for ventilation systems.
  • With non-glowing stainless steel tubular radiators.
  • Operate with ETL/DTL temperature controller (see accessories).
  • Increased danger of fire if tubular radiators are dirty. Install TFE air filter as a prevention.
  • Recommended accessories: FL channel sensor or FR room sensor, LW 9 air flow monitor, US 16 T contactor and TFE... air filter .

Installation instructions

  • Mount the water-air heater on the fan's pressure side in order to prevent fan motor overheating. An arrow marked on the housing shows the default air direction through the electrical air heater.
  • Mount a 1 m to 1.5 m long air duct fitting between fan and electrical air heater to ensure optimum inflow to the electrical air heater.
  • Inflow speed can be controlled using an LW 9 air flow monitor.
  • If the inflow speed falls below 1.5 m/s, the electrical air heater must be switched off.

Safety instructions

  • Increased danger of fire if the tubular radiators are dirty. Install TFE air filter as a prevention.
  • Design in accordance with VDE, Device and Product Security Laws and the corresponding EU Directives.
  • With 2 temperature limiters switching independently of each other.
  • Minimum distance to inflammable material: 150 mm (if distance is less, install appropriate insulation).

Table of contents

Wiring diagram

DRH 16-5 - Wiring diagram

Setting options for DRH...

S1 - system on

K1 - heating release

S - sensor

ERR - centrifugal duct fan

LW 9 - air flow monitor

ETL 16 P - electronic temperature controller

DTL 16 P - electronic temperature controller

FL 30 P - channel sensor for minimum or maximum limitation

FR 30 P - room sensor

DRH - electrical air heater

F1 - temperature limiter with manual reset

F2 - temperature limiter with automatic reset

N - night reduction

  1. External channel sensor and internal setpoint generator in ETL 16 P
  2. External room sensor and external setpoint generator
  3. External channel sensor and external setpoint generator
  4. Internal room sensor and internal setpoint generator in DTL 16 P


Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. Agreed

Acknowledgements Data protection