Centralised ventilation unit

WRG 400 EC

No longer available for delivery
Article number: 0082.0063
Manufacturer: MAICO
Centralised ventilation unit with very effective heat recovery through cross-counterflow exchanger, EC motors... more information
Application examples: Single-family house, Apartment, Office, Waiting room, Commercial premises
Product data sheet
WRG 400 EC IM0009847.PNG Centralised ventilation unit with very effective heat recovery through cross-counterflow exchanger, EC motors with constant volumetric flow regulation, 4 x DN 160, 70 - 400m³/h, KNX connection possible

Characteristic curve

WRG 400 EC - Characteristic curve WRG 400 EC

  1. 100 m3/h
  2. 150 m3/h
  3. 200 m3/h
  4. 250 m3/h
  5. 300 m3/h
  6. 350 m3/h
  7. 400 m3/h

Dimensioned drawing

WRG 400 EC - Dimensioned drawing [mm]

  1. DN 180 outside air
  2. DN 180 exhaust air
  3. DN 180 outgoing air
  4. DN 180 supply air
  5. Condensation connection
  6. Electrical connection

Technical data

WRG 400 EC - Technical data

Article WRG 400 EC
Number of ventilation levels 3
Air flow volume 70 m³/h - 400 m³/h
Volumetric flow constant yes
Speed controllable
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz/60 Hz
Power consumption 40 W - 270 W / At 100 Pa counter pressure
Imax 2,1 A
Degree of protection IP 31
DIBT approval No
PHI certification No
Installation site Cellar / Storage tank / Jamb wall / Utility room / Heating room
Housing material Sheet steel, powder coated
Heat exchanger material PETG plastic
Colour Pearl white, similar to RAL 1013
Weight 33 kg
Weight including packaging 35,5 kg
Filter class G4
Connection diameter 180 mm
Connection diameter of condensation drain 1/2" inside thread
Width 675 mm
Height 602 mm
Depth 430 mm
Width with packaging 760 mm
Height with packaging 740 mm
Depth with packaging 595 mm
Airstream temperature at IMax 50 °C
Degree of heat provision 90 %
Heat exchanger construction type Cross-counterflow
Bypass No
Frost protection External
Antifreeze circuit yes
Summer circuit No
Filter monitoring time controlled with RLS 2 F
Humidity control optional with HY 5, HY 5 I, HY 10 AP, HY 10 UP
CO2 regulation -
Air quality control (optional) -
KNX connection (optional) yes
Control unit included in scope of delivery. No
Control unit (optional) RLS 2 F, RLS 3
Wireless switch on/off (optional) XE 1, XS 1
Housing emission sound pressure level 53 dB(A) / Spacing 1m, sound absorption 10 m²
Packing unit 1 piece
Range K
GTIN (EAN) 4012799820635
Article number 0082.0063

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, Level 5 (dB(A))

31

39

46

46

46

45

51

43

55

LWA5, Level 5 (dB(A))

27

37

44

44

39

36

31

27

48

LWA6, Level 5 (dB(A))

40

55

59

64

64

62

59

54

69

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

LWA5, LWA6 = sound power level emitted to the free surroundings. Measured at an operating point on the connectors facing the room. LWA5 Exhaust air connections, LWA6 Supply air connections.

Measured at air volume of 320 m³/.

Accessories

WRG 400 EC - Accessories

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Air filter, replacement WRF 300-400 EC 0093.0061 on request
  • On the notes
Room air control RLS 3 0157.0831 on request
  • On the notes
Room air control RLS 2 F 0157.0806 on request
  • On the notes
Summer cassette SK 300 Plus No longer available for delivery 0180.0924 on request
  • On the notes

General accessories

Product type Name Art. No. Price*(EUR) Action
MAICOTherm ventilation duct system, thermally insulated MAICOTherm MT thermally-insulated ventilation duct system - - -
MAICOFlex ventilation duct system, round Flexible round MAICOFlex ventilation duct system - - -
Shutter AS 20 0151.0330 on request
  • On the notes
External grille MLA 20 0151.0111 on request
  • On the notes
Outside air wall connection KW-AL 20E 0152.0081 on request
  • On the notes
Outside air wall connection KW-AL 20W 0152.0082 on request
  • On the notes
Outgoing air wall connection KW-FL 20E 0152.0083 on request
  • On the notes
Outgoing air wall connection KW-FL 20W 0152.0084 on request
  • On the notes
Combi-wall connections KWH 20 L 0152.0063 on request
  • On the notes
Combi-wall connections KWH 20 R 0152.0062 on request
  • On the notes
Door ventilation grille MLK 30 white 0151.0123 on request
  • On the notes
Door ventilation grille MLK 45 white 0151.0126 on request
  • On the notes
Disk valve, synthetic material TK 10 0151.0192 on request
  • On the notes
Disk valve, synthetic material TK 12 0151.0198 on request
  • On the notes
Disk valve, stainless steel TM-V2A 10 0151.0374 on request
  • On the notes
Disk valve, stainless steel TM-V2A 12 0151.0375 on request
  • On the notes
Disk valve, metal TFA 10 0151.0369 on request
  • On the notes
Disk valve, metal TFA 12 0151.0370 on request
  • On the notes
Disk valve, metal TFZ 10 0151.0364 on request
  • On the notes
Disk valve, metal TFZ 12 0151.0365 on request
  • On the notes
Mounting frame for TFA/TFZ EBR-D 10 0092.0493 on request
  • On the notes
Mounting frame for TFA/TFZ EBR-D 12 0092.0494 on request
  • On the notes
Blower nozzle WD 10 W 0151.0290 on request
  • On the notes
Blower nozzle WD 10 D 0151.0291 on request
  • On the notes
Supply air valve ZWVQ 10 0152.0064 on request
  • On the notes
Supply air valve ZWVQ 12 0152.0065 on request
  • On the notes
Tubular sound absorber RSR 10 Remaining parts 0092.0311 on request
  • On the notes
Tubular sound absorber RSR 12 Remaining parts 0092.0312 on request
  • On the notes
Tubular sound absorber RSR 18 Remaining parts 0092.0315 on request
  • On the notes
Tubular sound absorber RSR 8-1 0092.0591 on request
  • On the notes
Tubular sound absorber RSR 10-1 0092.0592 on request
  • On the notes
Tubular sound absorber RSR 12-1 0092.0593 on request
  • On the notes
Tubular sound absorber RSR 18-1 0092.0596 on request
  • On the notes
Slide-in sound absorber SDE 8 0044.0213 on request
  • On the notes
Slide-in sound absorber SDE 10 0044.0214 on request
  • On the notes
Slide-in sound absorber SDE 12 0044.0215 on request
  • On the notes
Slide-in sound absorber SDE 16 0044.0216 on request
  • On the notes
Electrical air heater ERH 16-2 0082.0102 on request
  • On the notes
Water air heater WRH 16-2 0082.0118 on request
  • On the notes
Air filter TFE 20-4 0149.0078 on request
  • On the notes
Air filter TFE 20-7 0149.0053 on request
  • On the notes
Thermostat TH 10 0157.0764 on request
  • On the notes
Channel sensor FL 30 P 0157.0780 on request
  • On the notes
Room sensor FR 30 P 0157.0781 on request
  • On the notes
Air flow monitor LW 9 0157.0779 on request
  • On the notes
Tubular sound absorber RSR 8 No longer available for delivery 0092.0310 on request
  • On the notes
Radio switch XS 1 No longer available for delivery 0157.0344 on request
  • On the notes
Radio receiver XE 1 No longer available for delivery 0157.0343 on request
  • On the notes
Brine-air heat exchanger EW-K 225 No longer available for delivery 0192.0520 on request
  • On the notes
Folded spiral-seams duct WFR 180 No longer available for delivery 0055.0080 on request
  • On the notes
Internal grille, adjustable AZE 100 No longer available for delivery 0059.0959 on request
  • On the notes
Internal grille, adjustable AZE 100 P No longer available for delivery 0059.0962 on request
  • On the notes
Tubular sound absorber RSR 18/50 No longer available for delivery 0092.0325 on request
  • On the notes
Air filter TFE 20-5 No longer available for delivery 0149.0062 on request
  • On the notes
Temperature control system ETL 16 P No longer available for delivery 0157.0824 on request
  • On the notes
Hygrostat HY 5 No longer available for delivery 0157.0123 on request
  • On the notes
Hygrostat HY 5 I No longer available for delivery 0157.0125 on request
  • On the notes
Hygrostat HY 10 AP No longer available for delivery 0157.0358 on request
  • On the notes
Hygrostat HY 10 UP No longer available for delivery 0157.0357 on request
  • On the notes

Product description

Productdescription

WRG 400 EC

short description

Centralised ventilation unit with very effective heat recovery through cross-counterflow exchanger, EC motors with constant volumetric flow regulation, 4 x DN 160, 70 - 400m³/h, KNX connection possible

Product description

Features

  • Special energy savings due to DC motors having a constant volumetric flow.
  • With sound-insulated fans for especially quiet running.
  • With automatic volumetric flow regulation for constant air quantities.
  • Sheet steel housing, powder-coated
  • Colour: pearl white, similar to RAL 1013.
  • Inner coating of heat resistant synthetic material, non-hygroscopic.
  • Easy filter change.
  • With two integrated G4 filters, filter change is possible without tools.
  • 4 DN 180 duct connections on the upper side of the unit.

Heat exchanger

  • Counterflow plate heat exchanger made of synthetic material (PETG).
  • The heat exchanger can be removed easily once the front plate has been unscrewed.
  • The heat exchanger can be easily cleaned using water.

Anti-frost protection

  • Guaranteed anti-frost protection ensures that the heat exchanger does not freeze.
  • The frost protection feature switches the supply air fan off when the outgoing air temperature is too low.
  • Heat recovery systems combined with earth heat exchangers or an electric frost protection feature to also ensure perfect operations at low temperatures. In the winter, the earth heat exchanger also guarantees extra heating power and in the summer, extra cooling power.

Heat recovery fan

  • 2 centrifugal DC fans, one fan each for supply air and exhaust air.
  • Fans with centrifugal impellers curved to the front.
  • 3 ventilation steps:
    • 1 = Basic ventilation/Night operation
    • 2 = Normal/Daytime operation
    • 3 = Intensive/Party operation
    • Factory setting: 100 / 200 / 300 m3/h
  • Within each ventilation level, the air volume can be adjusted from 70 m3/h up to 400 m3/h in 5 m3/h steps.

Mounting instructions

  • With bracket for wall installation, feet for floor installation.
  • Installation on the wall or a pedestal is required to ensure access to the condensation connection.
  • Housing covers can be unscrewed.
  • Provide sound absorbers on the inlet and outlet sides.

Electrical connection

  • When delivered, the device is assembled and ready for service.

Condensation drain

  • Condensation is drained out at the bottom of the unit. Condensation drainage (½" internal thread) for connection to a drain trap.

Table of contents

Wiring diagram

WRG 400 EC - Wiring diagram



WRG 180 EC / WRG 300 EC / WRG 400 EC with room air control RLS 3

Fuse protection provided by customer



Predecessor - successor

WRG 400 EC - Predecessor

Product type Name Art. No. Action
Aeronom room air system WRG 400 EC No longer available for delivery 0082.0061
  • On the notes

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings