Axial duct fan

DZL 56/4 B

No longer available for delivery
Article number: 0086.0090
Manufacturer: MAICO
Axial duct fan, DN 560, three-phase AC
Application examples: Machine extraction unit, Workplace air extraction system, Workshop, Foreman's office, Production site
DZL 56/4 B IM0014274.PNG Axial duct fan, DN 560, three-phase AC

Characteristic curve

DZL 56/4 B - Characteristic curve

Dimensioned drawing

DZL 56/4 B - Dimensioned drawing [mm]

Number of flange holes: 16

Technical data

DZL 56/4 B - Technical data

Article DZL 56/4 B
Model Stabiliser
Air flow volume 12.300 m³/h
Speed controllable
Reversing capacity
Type of voltage Three-phase AC
Rated voltage 400 V
Frequency 50 Hz
Imax 3,5 A
Degree of protection IP 55
Insulation class F
Pole-changeable
Installation position vertical / horizontal
Material Sheet steel, galvanised
Weight 36,6 kg
Nominal size 560 mm
Airstream temperature at nominal current 60 °C
Airstream temperature at IMax -20 °C up to 60 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799860907
Article number 0086.0090
Article DZL 56/4 B
Total efficiency η 48,3 %
Measurement category D
Efficiency category total
Efficiency level N 54,3
VSD necessary No
Year of manufacture see rating plate
Manufacturer’s name / official registration number / manufacturer's place of establishment Maico Elektroapparate-Fabrik GmbH / Freiburg registration court, HRB 601233 / Villingen-Schwenningen
Art. No. 0086.0090
PBEP / Air volumeBEP / Pfs, BEP 1,12 kW / 8.280 m³/h / 235 Pa
nBEP 1.390 1/min
Specific ratio ≈ 1
Information about dismantling and disposal see mounting instructions
Information about installation, operation and repairs see mounting instructions
Objects used to measure efficiency which are not described by the measurement category -
IBEP 2 A
Sound power levelLWA5 84 dB(A)

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, S1 (dB(A))

35

38

46

45

44

37

31

21

51

LWA2, S2 (dB(A))

36

51

51

60

55

51

42

29

62

LWA2, S3 (dB(A))

40

53

65

61

60

50

37

22

68

LWA2, S4 (dB(A))

44

56

59

69

68

63

57

44

73

LWA2, S5 (dB(A))

47

56

65

72

74

67

61

49

77

LWA5, S1 (dB(A))

40

47

60

59

55

52

43

30

64

LWA5, S2 (dB(A))

35

58

65

68

67

65

57

45

73

LWA5, S3 (dB(A))

38

63

66

76

75

72

65

53

80

LWA5, S4 (dB(A))

41

68

70

78

79

76

69

58

83

LWA5, S5 (dB(A))

42

61

78

85

83

79

73

62

88

LWA6, S1 (dB(A))

46

48

58

60

65

65

67

65

72

LWA6, S2 (dB(A))

51

61

69

72

75

74

76

73

82

LWA6, S3 (dB(A))

60

68

74

81

83

82

82

79

89

LWA6, S4 (dB(A))

64

69

77

83

86

84

84

81

91

LWA6, S5 (dB(A))

66

71

80

88

90

88

88

85

95

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

Accessories

DZL 56/4 B - Accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
Shutter AS 60 0151.0337 on request
  • On the notes
Shutter, manual RS 60 0151.0345 on request
  • On the notes
Servomotor MS 2 0093.0403 on request
  • On the notes
Protective grille, metal SG 56 0150.0121 on request
  • On the notes
Flexible coupling ELA 56 0092.0272 on request
  • On the notes
Flexible cuff EL 56 0092.0150 on request
  • On the notes
Mounting and sealing material BD 56 Discontinued product 0092.0140 on request
  • On the notes
Counter flange GF 56 0056.0010 on request
  • On the notes
Counter socket GS 56 0055.0176 on request
  • On the notes
Suction nozzle AD 56 Discontinued product 0180.0626 on request
  • On the notes
Mounting foot FU 56 0036.0076 on request
  • On the notes
Vibration damper GP 20 0092.0152 on request
  • On the notes
Main switch, service switch HS 3 0157.0736 on request
  • On the notes
Motor protection switch MV 25 0157.0712 on request
  • On the notes
5-step transformer TR 6,6-2 0157.0150 on request
  • On the notes
5-step transformer, control cabinet TR 6,6 S-2 0157.0153 on request
  • On the notes
5-step switch for TRE...S -2/ TR...S-2 5-step transformers DSS 20 0157.0750 on request
  • On the notes
5-step transformer, control cabinet TR 6,6 S No longer available for delivery 0157.0743 on request
  • On the notes
Temperature control system ATS No longer available for delivery 0157.0759 on request
  • On the notes
Temperature control system, power module ATL 6 No longer available for delivery 0157.0758 on request
  • On the notes

Product description

Productdescription

DZL 56/4 B

short description

Axial duct fan, DN 560, three-phase AC

Product description

Features

  • Duct sleeve made of galvanised sheet steel, with flanges and guided vanes on both sides.
  • 8-blade impellers made of glass-fibre filled polyamide. Dynamically balanced at two levels, in accordance with performance level 6.3, DIN ISO 1940, Part 1.
  • Flange holes in accordance with DIN 24154, page 2, 7/66.
  • DZL 56/6 B and DZL 56/4 B: Flange holes in accordance with DIN 24145, part 2, 7/90.
  • High degree of protection IP 55.
  • To prevent transfer of vibrations onto the duct system: Use flexible couplings, feet and vibration dampers.
  • Can be fitted in any position.

Motor

  • Asynchronous motor, speed controllable. Exception: Type DZL 40/2 B.
  • Not suitable for ventilating steam-saturated air.
  • EZL / DZL duct fans are non reversible.

Three-phase AC motor

  • DZL series
  • Rated voltage 400 V, 50 Hz.
  • Thermal overload protection as a standard feature. Available on request for pole changeable axial duct fans.
  • Potential-free terminal connection, which must be connected to e.g. an MV 25 full motor protection switch or the control circuit of a contactor.
  • Pole-changeable motors with speed ratios of 8/4 or 4/2 have a Dahlander pole-changing circuit.

Electrical connection

  • Terminal box with cable sleeves fitted on the outside.

Safety instructions

  • The fan can be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN 13857 for fans with a free inlet.

Special versions

  • The following special versions are available at extra cost on request:
    • Special voltages and frequencies.
    • Single-phase motors with thermal contacts or PTC thermistor, with potential-free terminal connections.
    • Condensation drainage holes.
    • Fans with enhanced anti-corrosion protection.
    • Impellers made of aluminium.
  • Information on operation at temperatures occasionally below -20°C available upon request.
  • If operating with frequency converters, the factory must be consulted.
  • Feasibility must be checked in each case.

Table of contents

Wiring diagram

DZL 56/4 B - Wiring diagram

DZL...B standard (counter-clockwise, 1 speed)

SC - Protection contact

TK - Thermal contact



DZL...B standard (anti-clockwise, 1 speed) with MV 25 full protection motor switch


DZL...B standard (anti-clockwise, 1 speed) with TR... 5-step transformer and MV 25 full protection motor switch


DZL... Standard (anti-clockwise, 1 speed) with TRV... 5-step transformer


Predecessor - successor

DZL 56/4 B - Successor

Product type Name Art. No. Action
Axial duct fan DZR 56/4 B 0086.0037
  • On the notes

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Cookies are used on this website, which are necessary for technical reasons, so that we can present users our offers. A cookie that saves your current privacy settings is also used (selection cookie). With the exception of the above-mentioned selection cookie, technically non-essential cookies and tracking mechanisms that enable us to provide you with an optimal user experience as well as customised offers (marketing cookies and tracking mechanisms) are only used if you have previously approved their use by clicking ACCEPT. Details and options for changing your settings at a later date can be found in our cookie settings.

ACCEPT ALL COOKIES Continue with necessary cookies


Acknowledgements | Data protection