Aeronom room air system

WS 600

No longer available for delivery
Article number: 0095.0056
Manufacturer: MAICO
Compact ventilation system with very efficient heat recovery, summer/winter operation and constant volumetric... more information
Application examples: Single-family house, Office
WS 600 IM0009844.PNG Compact ventilation system with very efficient heat recovery, summer/winter operation and constant volumetric flow
WS 600 IM0016031.PNG Compact ventilation system with very efficient heat recovery, summer/winter operation and constant volumetric flow

Characteristic curve

WS 600 - Characteristic curve

  • WS 600 IM0006418.PNG Compact ventilation system with very efficient heat recovery, summer/winter operation and constant volumetric flow

LT - Power unit setting

WS 600 - Characteristic curve

  • WS 600 IM0006420.PNG Compact ventilation system with very efficient heat recovery, summer/winter operation and constant volumetric flow
  1. Step 1 = 200 m3/ h
  2. Step 2 = 300 m3/ h
  3. Step 3 = 400 m3/ h

Dimensioned drawing

WS 600 - Dimensioned drawing [mm]

  • WS 600 IM0006423.PNG Compact ventilation system with very efficient heat recovery, summer/winter operation and constant volumetric flow
  1. Outside air
  2. Exhaust air
  3. Supply air
  4. Outgoing air
  5. Condensation connection
  6. Electrical connection

Technical data

WS 600 - Technical data

Article WS 600
Air flow volume 200 m³/h / 550 m³/h
Rotating speed 2.070 1/min
Speed controllable
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz/60 Hz
Maximum power consumption 220 W
Imax 1 A
Degree of protection IP 00
Installation site Cellar / Storage tank / Jamb wall / Utility room / Heating room
Housing material Sheet steel, galvanised
Colour Light grey
Weight 100
Filter class G4
Connection diameter 224 mm
Width 700 mm
Height 1.190 mm
Depth 560 mm
Airstream temperature at IMax 50 °C
Ambient temperature 50 °C
Degree of heat provision 90 %
Heat exchanger construction type Condensation rotor
Packing unit 1 piece
Range K
GTIN (EAN) 4012799950561
Article number 0095.0056

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, Level 3 (dB(A))

45

48

46

38

32

33

36

28

51

LWA5, Level 3 (dB(A))

35

40

39

39

39

20

15

5

46

LWA6, Level 3 (dB(A))

38

51

54

58

59

44

39

40

63

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

Accessories

WS 600 - Accessories

Specific accessories

Product typeNameArt. No.Price*(EUR)Action
Air filter, replacementWSG 6000093.0886 on request
  • On the notes

General accessories

Product typeNameArt. No.Price*(EUR)Action
Roof outletDF---
Roofing tileDP---
Mounting clampBS---
Rain protection grilleRG---
MAICOFlex ventilation duct system, roundFlexible round MAICOFlex MF ventilation duct system---
MAICO FFS ventilation duct system, flatMAICO FFS flexible flat ventilation duct system---
MAICOFlex ventilation duct system, roundFlexible round MAICOFlex ventilation duct system---
Stainless steel cowl LH-V2A 100151.0377 on request
  • On the notes
Stainless steel cowl LH-V2A 120151.0378 on request
  • On the notes
Internal grilleESG 10/20059.0947 on request
  • On the notes
Door ventilation grilleMLK 30 white0151.0123 on request
  • On the notes
Door ventilation grilleMLK 45 white0151.0126 on request
  • On the notes
Exhaust and supply air valveAZV 1000152.0087 on request
  • On the notes
Disk valve, synthetic materialTK 100151.0192 on request
  • On the notes
Disk valve, synthetic materialTK 120151.0198 on request
  • On the notes
Disk valve, metalTM 100151.0194 on request
  • On the notes
Disk valve, metalTM 120151.0196 on request
  • On the notes
Disk valve, stainless steelTM-V2A 100151.0374 on request
  • On the notes
Disk valve, stainless steelTM-V2A 120151.0375 on request
  • On the notes
Disk valve, metalTFA 100151.0369 on request
  • On the notes
Disk valve, metalTFA 120151.0370 on request
  • On the notes
Disk valve, metalTFZ 100151.0364 on request
  • On the notes
Disk valve, metalTFZ 120151.0365 on request
  • On the notes
Mounting frame for TFA/TFZEBR-D 100092.0493 on request
  • On the notes
Mounting frame for TFA/TFZEBR-D 120092.0494 on request
  • On the notes
Blower nozzleWD 10 W0151.0290 on request
  • On the notes
Blower nozzleWD 10 D0151.0291 on request
  • On the notes
Grease filter element for exhaust airFFE 100092.0506 on request
  • On the notes
Tubular sound absorberRSR 200092.0316 on request
  • On the notes
Tubular sound absorberRSR 10/500092.0321 on request
  • On the notes
Tubular sound absorberRSR 12/500092.0322 on request
  • On the notes
Tubular sound absorberRSR 20/500092.0326 on request
  • On the notes
Slide-in sound absorberSDE 80044.0213 on request
  • On the notes
Slide-in sound absorberSDE 100044.0214 on request
  • On the notes
Slide-in sound absorberSDE 120044.0215 on request
  • On the notes
Slide-in sound absorberSDE 160044.0216 on request
  • On the notes
Electrical air heaterERH 20-20082.0103 on request
  • On the notes
Water air heaterWRH 20-20082.0119 on request
  • On the notes
Air filterTFE 20-40149.0078 on request
  • On the notes
Air filterTFE 20-50149.0062 on request
  • On the notes
Air filterTFE 20-70149.0053 on request
  • On the notes
Temperature control systemETL 16 PNo longer available for delivery0157.0824 on request
  • On the notes
Channel sensorFL 30 P0157.0780 on request
  • On the notes
Brine-air heat exchangerEW-K 225No longer available for delivery0192.0520 on request
  • On the notes
Folded spiral-seams ductWFR 200No longer available for delivery0055.0081 on request
  • On the notes
Internal grille, adjustableAZE 100No longer available for delivery0059.0959 on request
  • On the notes
Internal grille, adjustableAZE 100 PNo longer available for delivery0059.0962 on request
  • On the notes

Product description

Productdescription

WS 600

short description

Compact ventilation system with very efficient heat recovery, summer/winter operation and constant volumetric flow

Product description

Features

  • Automatic constant volumetric flow regulation for equal air quantities.
  • Special energy savings due to the DC motor.
  • Integrated filter system with coarse filter (G4) in the outside air and in the exhaust air. Filter change is possible without tools.
  • Electronic filter monitoring with filter change warning displayed on the operator unit.
  • 4 DN 225 duct connections with with rubber lip seals. Of which 2 are on the top of the unit and 1 is fitted on each side wall. For directly connecting up tubular sound absorbers.
  • Controlled from the operator unit in the living room.
  • Operator unit for switching fan steps, timer, filter pollution display included in scope of delivery.

Heat exchanger

  • Counterflow heat exchanger made of aluminium.
  • The heat exchanger can be easily removed and cleaned with water.

Anti-frost protection

  • Always combine heat recovery systems with earth heat exchangers, in order to be able to guarantee trouble-free operation, even at very low temperatures. Furthermore, an earth heat exchanger guarantees additional heater power rating in winter and additional cooling power in summer.

Heat recovery fan

  • 2 centrifugal DC fans, one fan each for supply air and exhaust air.
  • 3 ventilation steps:
    • 1 = Basic ventilation/Night operation
    • 2 = Normal / Daytime operation
    • 3 = Intensive / Party operation
    • Factory setting: 270 m3/h / 350 m3/h / 450 m3/h

Mounting instructions

  • The front plate can be hinged open for changing the filter.
  • Allow for sufficient space at the side walls when installing.
  • Decouple the housing with impact sound plates for sound insulation.

Electrical connection

  • The attached operator unit is connected to the central unit via a 5-core, screened cable (maximum length 100 m).

Condensation drain

  • Condensation is drained from the side of the unit using a hose (DN 1/2") connected to a siphon.

Table of contents

Wiring diagram

WS 600 - Wiring diagram

WS 600

Terminal assignment:

1, 2, 3 - 230 V, 50 Hz connection for mains supply

4, 5 - Electrical pre-heating contact (option)

6, 7 - Electrical re-heating contact (option)

8, 9, 10 - Heating circulation pump for hydraulic re-heating (option)

14, 15, 16 - Re-heating thermal valve / Controller for electrical re-heating (option)

17, 18 - Outgoing air temperature sensor

19, 20 - Outside air temperature sensor

21, 22 - Supply air temperature sensor

23, 24, 25, 26, 27 - Remote control interface (minimum 5 x 0.22 m2, screened)



WS 600 with DRH electrical air heater

LW 9 - air flow monitor

S - sensor

K1 - Contactor, electrical pre-heating, e.g. US 16 T

K2 - Contactor, electrical re-heating, e.g. US 16 T

DRH - electrical air heater

VH - Electrical pre-heating

NH - Electrical re-heating



Predecessor - successor

WS 600 - Successor

Product typeNameArt. No.Action
Centralised ventilation unitWR 600No longer available for delivery0095.0080
  • On the notes

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. Agreed

Acknowledgements Data protection