High pressure centralised exhaust air unit without heat recovery
Application examples: Low-energy house, Single-family house, Apartment, Living room, Redevelopment
ZEG 2000 P IM0009838.PNG High pressure centralised exhaust air unit without heat recovery

Characteristic curve

ZEG 2000 P - Characteristic curve

  • ZEG 2000 P IM0003223.PNG High pressure centralised exhaust air unit without heat recovery

Dimensioned drawing

ZEG 2000 P - Dimensioned drawing [mm]

  • ZEG 2000 P IM0006447.PNG High pressure centralised exhaust air unit without heat recovery

Technical data

ZEG 2000 P - Technical data

Article ZEG 2000 P
Air flow volume 310 m³/h / System pressure at 100 Pa
Rotating speed 690 1/min / 1.145 1/min / 1.825 1/min
SEC average -9,1 kWh/(m²*a)
Energy efficiency class F
Type of voltage Alternating current
Rated voltage 230 V
Power consumption 14 W / 42 W / 92 W
Imax 0,14 A / 0,3 A / 0,4 A
Degree of protection IP 20
Installation site Cellar / Storage tank / Jamb wall / Utility room / Heating room
Installation position vertical / horizontal
System type Centralised
Material Synthetic material
Weight 3,4 kg
Connection diameter 125 mm
Width 360 mm
Height 280 mm
Depth 278 mm
Sound pressure level 33 dB(A) / 41 dB(A) / 49 dB(A)
Packing unit 1 piece
Range K
GTIN (EAN) 4012799862031
Article number 0086.0203

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, high (dB(A))

23

41

54

48

49

45

45

42

57

LWA2, medium (dB(A))

21

35

43

42

42

43

33

28

49

LWA2, low (dB(A))

21

20

31

32

39

30

7

5

41

LWA5, high (dB(A))

42

55

54

54

52

49

53

48

61

LWA5, medium (dB(A))

32

43

44

44

42

37

39

31

50

LWA5, low (dB(A))

22

26

30

31

28

17

19

7

36

LWA8, high (dB(A))

41

48

55

55

62

58

55

51

65

LWA8, medium (dB(A))

31

36

43

44

50

47

41

33

53

LWA8, low (dB(A))

22

22

31

36

43

30

13

3

44

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA8= housing and free outlet sound power level in dB.

Accessories

ZEG 2000 P - Accessories

Specific accessories

Product typeNameArt. No.Price*(EUR)Action
Room air controlRLS 30157.0831 on request
  • On the notes

General accessories

Product typeNameArt. No.Price*(EUR)Action
MAICOTherm ventilation duct system, thermally insulatedMAICOTherm MT thermally-insulated ventilation duct system---
Roof outletDF---
Roofing tileDP---
Mounting clampBS---
Rain protection grilleRG---
MAICOFlex ventilation duct system, roundFlexible round MAICOFlex MF ventilation duct system---
MAICO FFS ventilation duct system, flatMAICO FFS flexible flat ventilation duct system---
MAICOFlex ventilation duct system, roundFlexible round MAICOFlex ventilation duct system---
Stainless steel cowl LH-V2A 120151.0378 on request
  • On the notes
Stainless steel cowl LH-V2A 150151.0379 on request
  • On the notes
Stainless steel cowl LH-V2A 160151.0380 on request
  • On the notes
Outgoing air wall connectionKW-FL 12E0152.0075 on request
  • On the notes
Outgoing air wall connectionKW-FL 12W0152.0076 on request
  • On the notes
Outgoing air wall connectionKW-FL 16E0152.0079 on request
  • On the notes
Outgoing air wall connectionKW-FL 16W0152.0080 on request
  • On the notes
Outside air openingALD 100152.0054 on request
  • On the notes
Outside air openingALD 1250152.0067 on request
  • On the notes
Outside air openingALD 125 VA0152.0068 on request
  • On the notes
Outside air openingALD 1600152.0069 on request
  • On the notes
Outside air openingALD 160 VA0152.0070 on request
  • On the notes
Outside air openingZE 45 F whiteNo longer available for delivery0152.0044 on request
  • On the notes
Internal grilleESG 10/20059.0947 on request
  • On the notes
Door ventilation grilleMLK 30 white0151.0123 on request
  • On the notes
Door ventilation grilleMLK 45 white0151.0126 on request
  • On the notes
Exhaust and supply air valveAZV 1000152.0087 on request
  • On the notes
Disk valve, synthetic materialTK 100151.0192 on request
  • On the notes
Disk valve, synthetic materialTK 120151.0198 on request
  • On the notes
Disk valve, metalTM 100151.0194 on request
  • On the notes
Disk valve, metalTM 120151.0196 on request
  • On the notes
Disk valve, stainless steelTM-V2A 100151.0374 on request
  • On the notes
Disk valve, stainless steelTM-V2A 120151.0375 on request
  • On the notes
Disk valve, metalTFA 100151.0369 on request
  • On the notes
Disk valve, metalTFA 120151.0370 on request
  • On the notes
Mounting frame for TFA/TFZEBR-D 100092.0493 on request
  • On the notes
Mounting frame for TFA/TFZEBR-D 120092.0494 on request
  • On the notes
Grease filter element for exhaust airFFE 100092.0506 on request
  • On the notes
Flexible aluminium ductAFR 1250055.0091 on request
  • On the notes
Tubular sound absorberRSR 120092.0312 on request
  • On the notes
Tubular sound absorberRSR 12/500092.0322 on request
  • On the notes
Slide-in sound absorberSDE 80044.0213 on request
  • On the notes
Slide-in sound absorberSDE 100044.0214 on request
  • On the notes
Slide-in sound absorberSDE 120044.0215 on request
  • On the notes
Folded spiral-seams ductWFR 125No longer available for delivery0055.0077 on request
  • On the notes
Internal grille, adjustableAZE 100No longer available for delivery0059.0959 on request
  • On the notes
Outside air openingALD 10 TNo longer available for delivery0152.0055 on request
  • On the notes

Product description

Productdescription

ZEG 2000 P

short description

High pressure centralised exhaust air unit without heat recovery

Product description

Features

  • Central ventilation unit.
  • For simultaneous air extraction of a number of rooms in single family-unit houses or apartments.
  • High pressure through centrifugal impeller.
  • Supply air intake by means of decentralised outside air openings, e.g. ALDs.
  • 3 ventilation levels can be set.
  • Up to 3 intake sockets for exhaust air, suitable for ducts with DN 125. The intake sockets can be broken-out if need be.
  • 1 DN 125 exhaust socket for outgoing air.

Motor

  • Motor designed for continuous operation.
  • Thermal overload protection as standard feature.

Mounting instructions

  • The housing can be fastened in any position to beams, walls or ceilings.

Electrical connection

  • When delivered, the device is assembled and ready for service.

Table of contents

Wiring diagram

ZEG 2000 P - Wiring diagram

ZEG 2000 P

1 = Low power

2 = Medium power

3 = High power

V distributor (supplied by the customer)



ZEG 2000 P with RLS 3 room air control

S1 - On / Off

S2 - low, medium, high power



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Cookies are used on this website, which are necessary for technical reasons, so that we can present users our offers. A cookie that saves your current privacy settings is also used (selection cookie). With the exception of the above-mentioned selection cookie, technically non-essential cookies and tracking mechanisms that enable us to provide you with an optimal user experience as well as customised offers (marketing cookies and tracking mechanisms) are only used if you have previously approved their use by clicking ACCEPT. Details and options for changing your settings at a later date can be found in our cookie settings.

ACCEPT ALL COOKIES Continue with necessary cookies


Acknowledgements | Data protection