Room air control

RLS 45 O

Article number: 0157.0359
Manufacturer: MAICO
Room air control as an accessory for the PP 45 K, PP 45 O and PPB 30 O final assembly kit, up to six units can... more information

Product data sheet
RLS 45 O IM0017207.PNG Room air control as an accessory for the PP 45 K, PP 45 O and PPB 30 O final assembly kit, up to six units can be connected, 5 ventilation levels can be set, programs: continuous ventilation with heat recovery, cross-ventilation without heat recovery and automatic operating mode
RLS 45 O IM0019952.PNG Room air control as an accessory for the PP 45 K, PP 45 O and PPB 30 O final assembly kit, up to six units can be connected, 5 ventilation levels can be set, programs: continuous ventilation with heat recovery, cross-ventilation without heat recovery and automatic operating mode

Characteristic curve

Dimensioned drawing

Technical data

RLS 45 O - Technical data

Article RLS 45 O
Rated voltage 230 V
Mains cable 3 x 1,5 mm²
Installation site Wall
Type of installation Recessed-mounted
Material Synthetic material
Colour Pure white, similar to RAL 9010
Weight 0,11 kg
Weight including packaging 0,33 kg
Width 80 mm
Height 80 mm
Depth 49 mm
Width with packaging 81 mm
Height with packaging 81 mm
Depth with packaging 50 mm
Packing unit 1 piece
Range K
GTIN (EAN) 4012799573593
Article number 0157.0359

Accessories / Accessories of

RLS 45 O - Accessories / Accessories of

Specific accessories

is a special accessory of

Product description

Productdescription

RLS 45 O

short description

Room air control as an accessory for the PP 45 K, PP 45 O and PPB 30 O final assembly kit, up to six units can be connected, 5 ventilation levels can be set, programs: continuous ventilation with heat recovery, cross-ventilation without heat recovery and automatic operating mode

Product description

Special features

  • With the control unit, 5 ventilation levels PP45-15/20/30/36/42m³/h and PPB 30 - 5/12/18/22/26 m³/h and 3 operating modes – continuous ventilation (with heat recovery), cross-ventilation (without heat recovery) and sensor-guided automatic operation can be selected.
  • Continuous ventilation mode with heat recovery: PushPull mode. The units run in alternation and change direction every 60 s.
  • Cross-ventilation operating mode: One unit is permanently in supply air mode and the corresponding unit in exhaust air mode (e.g for summer night cooling).
  • In automatic operating mode, the air volume is adjusted continuously to the sensor value (HYI, HY, CO2, VOC).
  • The RLS 45 O room air control can be extended with the internal humidity sensor or with the external sensors (humidity, CO2, VOC). In the process, the air volume is adjusted and the units achieve energy efficiency class A+.
  • Operation of odd number of units is possible. The volumetric flows are automatically divided according to the number of units.
  • ModBus connection possible.
  • The control system can be extended with further control systems or PP 45 LT power units.

Features

  • The room air control is needed as an accessory for the PP 45 K, PP 45 O or PPB 30 O final installation kits.
  • The PPB 30 K final installation kit cannot be operated in conjunction with the RLS 45 O room air control.
  • Up to 6 PP 45 units or up to 3 PPB 30 O units can be controlled at the same time via an RLS 45 O room air control.

Table of contents

Wiring diagram

RLS 45 O - Wiring diagram

RLS 45 O - PushPull 45 object room air control

PP 45 O - PushPull 45 object ventilation unit

Fan 1.1 - fan unit 1, unit pair 1

Fan 2.1 - fan unit 2, unit pair 1

Fan 1.2 - fan unit 1, unit pair 2

Fan 2.2 - fan unit 2, unit pair 2

Fan 1.3 - fan unit 1, unit pair 3

Fan 2.3 - fan unit 2, unit pair 3

UP-L -Recessed-mounted distributor connection for fan units, connection of all fan units in star shape to distributor

W-F1 - Fan 1 control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. length to distributor 4m.

W-F2 - Fan 2 control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. length to distributor 4m.

W1.X - Fan unit control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25m.

W2.X - Fan unit control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25m.

W3 - Bus (RS-485) connection cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. cable length to the sensors, RLS, LT and EnOcean module approx. 100m. Alternatively, this connection can also be used as a ModBus RTU interface.



RLS 45 O - PushPull 45 object room air control

PPB 30 O - PushPull Balance 30 object ventilation unit

X 1.1 - RLS - Mains connection terminal

X 1.2 - RLS - Fan/bus connection terminal

UP-L - Recessed-mounted distributor connection for fan units, connection of all fan units in star shape to distributor

W-F1 - Fan 1 control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. length to distributor 4m.

W-F2 - Fan 2 control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. length to distributor 4m.

W1.X - Fan unit control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25 m.

W3 - Bus (RS-485) connection cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. cable length to the sensors, RLS, LTs approx. 100 m. Alternatively, this connection can also be used as a ModBus RTU interface.



RLS 45 O - 45 object room air control

PP 45 LT - PP 45 power unit

PP 45 HY - PP 45 humidity sensor for recessed mounting

PP 45 CO2 - PP45 CO2 sensor for recessed mounting

PP 45 VOC - PP45 VOC sensor for recessed mounting

Fan 1.1-1.3 - Fan unit 1 and 3 on RLS master

Fan 2.1-2.3 - Fan unit 2 and 4 on RLS master

Fan 3 + 4 G1-3 - Fan unit 6,7,8 on RLS slave 1

Fan 5.1-5.3 - Fan unit 9,11,13 on RLS slave 2

Fan 6.1-6.3 - Fan unit 10,12,14 on RLS slave 2

UP-B - Recessed-mounted distributor bus, connection of RLS, LT, EO and sensors using RS-485 bus interface

W1.X - Bus (RS-485) connection cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. cable length to the sensors, RLS, LTs and EnOcean module approx. 100 m. Alternatively, this connection can also be used as a ModBus RTU interface.



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings