Application example

1 | RV 2 Horizontal parapet variant |
2 | RV 2 Vertical, straight soffit variant |
3 | RV 2 Vertical, 90° left soffit variant |
4 | Bathroom exhaust air fan on 230 V interface of the RLS 45 K |
5 | RLS 45 K comfort control |
① | Minimum distance between 2 RV 2 ventilation units = 2 m |
- Ventilation units: Install at least 1 RV 2 unit pair and a maximum of 8 RV 2 units.
- Controls: In addition to the master controller, 3 further controllers (slaves) are permitted on the RS 485 bus.
- Keep a minimum distance of 2 m between 2 ventilation units if they are in heat recovery mode, otherwise ventilation short circuit. If the RV 2 units change to supply air and exhaust air at the same time, the minimum distance is irrelevant.
- Bathroom: The use of RV 2 units in bathrooms is only permitted outside the protection zones.
- Kitchens, open-plan kitchens, dining kitchens: The use of RV 2 in kitchens is permitted. We only recommend an exhaust air fan or two RV 2 ventilation units in spatially separated kitchens. The exhaust air fan (ER, ECA 100 ipro) can be connected to the 230 V interface of the RLS 45 K.