Final assembly kit

RV 2

Article number: 0095.0665
Final installation kit for RotationVent RV 2 single-room ventilation unit with heat recovery, consisting of... more information
Application examples: Living areas, Individual rooms, Supply air rooms
Product data sheet
RV 2 IM0023355.PNG Final installation kit for RotationVent RV 2 single-room ventilation unit with heat recovery, consisting of fan unit, plastic heat exchanger, internal cover, 1 x ISO Coarse 30 % (G2) filter and 1 x ISO Coarse 45 % (G3) filter, accessories needed: Pre-installation set, external cover and RLS 45 K room air control

Characteristic curve

Dimensioned drawing

RV 2 - Dimensioned drawing [mm]

Technical data

RV 2 - Technical data

Article RV 2
Air flow volume 15 m³/h / 22 m³/h / 30 m³/h / 36 m³/h / 42 m³/h
Rotating speed 3.800 1/min
SEC average -37,78 kWh/(m²*a)
Energy efficiency class A
Rated voltage 12 V DC
SPI value in accordance with DIN EN 13141-7 (A7) 0,14 Wh/m³
Maximum power consumption 1,2 W / 1,4 W / 1,9 W / 2,2 W / 2,5 W
Degree of protection IP 00
Installation site Wall
Material Synthetic material
Housing material Synthetic material
Heat exchanger material Synthetic material
Colour similar to traffic white, RAL 9016
Weight 2,5 kg
Weight including packaging 3 kg
Type of filter Outside and exhaust air filter
Filter class ISO Coarse 45% (G3) / ISO Coarse 30% (G2)
Width 310 mm
Height 87 mm
Depth 305 mm
Width with packaging 315 mm
Height with packaging 150 mm
Depth with packaging 400 mm
Wall thickness 365 - 500 mm
Airstream temperature at IMax 40 °C
Ambient temperature 40 °C up to -15 °C
Degree of heat provision with reference volumetric flow according to DIN EN 13141-8 83 %
Sound pressure level 19 dB(A) / 24 dB(A) / 25 dB(A) / 29 dB(A) / 31 dB(A) / Distance 1 m, free-field conditions
Rated max. element normal difference in noise level Dn,w / Measured with RV 2 VH, 48 dB closed, 39 dB open; measured with RV 2 VV, 48 dB closed, 39 dB open; measured with RV 2 VLL, 50 dB closed, 45 dB open; measured with RV 2 VLR, 50 dB closed, 45 dB open; measured with RV 2 VS, 56 dB closed, 47 dB open
Rated sound reduction index Rw,R / Measured with RV 2 VH, 24.5 dB closed, 15.5 dB open; measured with RV 2 VV, 24.5 dB closed, 15.5 dB open; measured with RV 2 VLL, 27.5 dB closed, 22.5 dB open; measured with RV 2 VLR, 27.5 dB closed, 22.5 dB open; measured with RV 2 VS, 32.5 dB closed, 23.5 dB open
Packing unit 1 piece
Range N
GTIN (EAN) 4012799956655
Article number 0095.0665

Product description

Productdescription

RV 2

short description

Final installation kit for RotationVent RV 2 single-room ventilation unit with heat recovery, consisting of fan unit, plastic heat exchanger, internal cover, 1 x ISO Coarse 30 % (G2) filter and 1 x ISO Coarse 45 % (G3) filter, accessories needed: Pre-installation set, external cover and RLS 45 K room air control

Product description

Features

  • Final installation kit for RotationVent RV 2 single-room ventilation unit with heat recovery, consisting of fan unit, plastic heat exchanger, inner cover, 1 x ISO Coarse 30% (G2) filter and 1 x ISO Coarse 45% (G3) filter, so that the air is filtered in both directions.
  • With the RV 2 units, a complete ventilation system in accordance with DIN 1946-6, including exhaust air units, can be set up via a central control system (RLS 45 K).
  • To achieve efficient ventilation, we recommend operating the units in pairs.
  • In certain system combinations, an odd number of units is also possible.

Special features

  • Flexible installation options thanks to various pre-installation kits. Positioned in the exterior wall, around the window or integrated into the window soffit, the RV 2 blends inconspicuously into the interior.
  • The innovative approach of a fan unit rotating around its own axis eliminates the typical switching noise of single-room ventilation units.
  • Turning the fan unit closes the air duct after switching off the RV 2 device. This function is similar to an automatic shutter.
  • Thanks to their extremely quiet and energy-efficient motors and excellent sensor-controlled operation, RV 2 units achieve energy efficiency class A+.
  • The fan unit can be removed without tools for cleaning and filter replacement. The two filters can also be replaced without tools.
  • The heat exchanger can be detached from the fan unit for cleaning purposes using a tool.
  • The devices can be operated in 5 different ventilation levels (15/22/30/36/42 m³/h) and in 3 operating programmes: continuous ventilation with heat recovery, cross ventilation and sensor-controlled automatic operation.
  • Flow-optimised external covers keep exhaust air away from the external façade.
  • Potential condensation is drained via an integrated condensation drip edge in the external cover.
  • Clear commissioning software and plug-and-play functioning for standard applications simplify commissioning. Settings can be saved and transferred to next controllers.

Required accessories

  • Pre-installation kit RV 2 (VH, VV, VLR, VLL, VS)
  • Room air control RLS 45 K
  • About RLS: External covers RV 2 (AH, AV, AL, VS 90E)

Optional accessories

  • Room air control RLS 45 K
  • PP 45 LT power unit
  • Humidity sensor PP 45 HY
  • Humidity sensor PP 45 HYI
  • PP 45 CO2 CO2 sensor
  • PP 45 VOC sensor

Mounting information

  • Mounting involves 2 steps:
  • Installation of a RotationVent RV 2 pre-installation kit.
  • The mounting sleeve is protected from contamination by plaster protection caps.
  • Then the final assembly kit is integrated and the external cover is attached.
  • No need to lay ducts.
  • The system requires no adjustment.

Electrical connection

  • When delivered, the unit is assembled and ready for service.
  • The electrical connection is made using a plug connection.
  • Connection to the RLS 45 K room air control unit via control cables.
  • The 12 VDC power line from the RLS 45 K room air control to the unit also serves as the control line.

Table of contents

Wiring diagram

RV 2 - Wiring diagram

RLS 45 K Final assembly kit

RV 2 #1 PushPull ventilation unit 1

RV 2 #2 PushPull ventilation unit 2

RV 2 #3 PushPull ventilation unit 3

S1 switch/button additional functions (sleep mode, intensive, imbalance and safety functions)

UP-L UP distributor fan units: all fan units connected in a star configuration to the distributor

W-B1 Recommended control cable for RLS 45 K control system to star point/distributor (max. 4 m): Type J-Y(ST)Y 2x2x0.8 mm²

W-RV 2 (X) Recommended control cable for RV 2 ventilation unit up to star point/distributor (max. 25 m): Type LiYY 4x0.5 mm²



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings