Cover

ER-A

Article number: 0084.0361
Manufacturer: MAICO
Cover for ER EC fan insert, standard model
Application examples: Bathroom, Kitchen, Multiple family unit, Day room, Dining room
Product data sheet
ER-A IM0017663.PNG Cover for ER EC fan insert, standard model

Characteristic curve

ER-A - Characteristic curve ER EC with ER GH exhaust opening at rear and ER GH AP/APB

I – level 1

II – level 2

  1. Factory settings for base and nominal load level in conjunction with ER-A cover
  2. Alternative settings for base and nominal load levels in conjunction with ER-AK/..-AH/..-AB covers

ER-A - Characteristic curve ER EC and ER EC RF17 with ER GH exhaust opening at side

I – level 1

II – level 2

  1. Factory settings for base and nominal load level in conjunction with ER-A cover
  2. Alternative settings for base and nominal load levels in conjunction with ER-AK/..-AH/..-AB covers

Dimensioned drawing

ER-A - Dimensioned drawing [mm]

Technical data

ER-A - Technical data

Article ER-A
Model Standard
Air flow volume 30 m³/h / 60 m³/h / (Level 1/level 2)
Air direction Air extraction
Degree of protection IP X5
Installation site Wall / Ceiling
System type Decentralised
Housing material Synthetic material
Colour Traffic white, similar to RAL 9016
Weight 0,47 kg
Weight including packaging 0,62 kg
Filter class ISO Coarse 30 % (G2)
Width 281 mm
Height 281 mm
Depth 33 mm
Width with packaging 310 mm
Height with packaging 300 mm
Depth with packaging 40 mm
Airstream temperature at IMax 40 °C
Start delay 60 s
Sound pressure level 15 dB(A) / 35 dB(A) / combined with ER GH; 31 dB(A) / 41 dB(A) combined with ER GH AP/APB/ Specification according to DIN 18017-3 with an equivalent absorption area AL = 10 m²
Approval number Z-51.1-478
Packing unit 1 piece
Range B
GTIN (EAN) 4012799843610
Article number 0084.0361

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA7, low (dB(A))

20

LWA7, high (dB(A))

39

LWA7= housing and free inlet sound power level in dB.

in combination with ER GH; 35 dB(A) / 45 dB(A) in combination with ER GH AP/APB

Accessories / Spare parts

ER-A - Accessories / Spare parts

Specific accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
Time delay switch VZ 6 0157.0820 on request
  • On the notes
Time delay switch VZ 12 0157.0821 on request
  • On the notes
Time delay switch VZ 24 C 0157.0822 on request
  • On the notes
Interval switch VZI 10 0157.0823 on request
  • On the notes
Timer ZS 4 0157.0088 on request
  • On the notes
Hygrostat HY 230 0157.0126 on request
  • On the notes
Hygrostat HY 230 I 0157.0127 on request
  • On the notes
Radio switch XS 1 No longer available for delivery 0157.0344 on request
  • On the notes
Radio receiver XE 1 No longer available for delivery 0157.0343 on request
  • On the notes

Spare parts

Product type Name Art. No. Price*(EUR) Action
Cover – upper part ABDO ER-A/AK/AH E059.2047.9100 on request
  • On the notes

Product description

Productdescription

ER-A

short description

Cover for ER EC fan insert, standard model

Product description

ER-A – standard model

  • Standard cover for ER EC with filter change indicator (time strip).
  • Base load: 30 m³/h / full load 60 m³/h.
  • Full load level on/off via light switch or separate switch.
  • Switching to full load level (60 m³/h) with start delay of approx. 60 sec.
  • Full load overrun time approx. 15 min.

Special features

  • Flow-optimised, attractive design
  • Filter can be changed without tools.
  • With filter change indicator.

Features

  • The unit can be run in continuous operation at the base load level.
  • IP X5 degree of protection for safety in the bathroom.
  • Colour: traffic white, similar to RAL 9016.
  • For single-room air extraction using a single fan.
  • ISO Coarse 30 % filter (G2), filter change without tools.
  • It is possible to rotate the cover by ± 5°, to compensate for housings which have been fitted at an angle.
  • Not speed controllable.
  • Switching option: The base load can be switched on or off by an additional switch (see the wiring diagrams online).

*Factory settings

Table of contents

Wiring diagram

ER-A - Wiring diagram

Connection variant 1, full load for ER-A, ER-AK, ER-AH, ER-AB

opt - optional

MS - motor control

Full load can be switched, no base load operation

Connection is made in the housing



Connection variant 2, base load/full load for ER-A, ER-AK, ER-AH, ER-AB

opt - optional

MS - motor control

Full load can be switched with permanent base load

Connection is made in the housing



Connection variant 3, base load/full load for ER-A, ER-AK, ER-AH, ER-AB

opt - optional

MS - motor control

Base and full load can be switched

Connection is made in the housing



Connection variant for interval, humidity, movement for ER-AK, ER-AH, ER-AB

MS - motor control

Connection is made in the housing



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings