Cover

ER-A

Article number: 0084.0361
Manufacturer: MAICO
Cover for ER EC fan insert, standard model
Application examples: Bathroom, Kitchen, Multiple family unit, Day room, Dining room
ER-A IM0017663.PNG Cover for ER EC fan insert, standard model

Characteristic curve

ER-A - Characteristic curve ER EC with air outlet at rear

  • ER-A IM0018411.PNG Cover for ER EC fan insert, standard model

I - level 1

II - level 2

  1. Factory settings for base and nominal load level in conjunction with ER-A cover
  2. Alternative settings for base and nominal load levels in conjunction with ER-AK/..-AH/..-AB covers

ER-A - Characteristic curve ER EC with air outlet at side

  • ER-A IM0017658.PNG Cover for ER EC fan insert, standard model

I - level 1

II - level 2

  1. Factory settings for base and nominal load level in conjunction with ER-A cover
  2. Alternative settings for base and nominal load levels in conjunction with ER-AK/..-AH/..-AB covers

Dimensioned drawing

ER-A - Dimensioned drawing [mm]

  • ER-A IM0017288.PNG Cover for ER EC fan insert, standard model

Technical data

ER-A - Technical data

Article ER-A
Model Standard
Air flow volume 30 m³/h / 60 m³/h / (Level 1/level 2)
Rotating speed 800 1/min / 1.250 1/min
Air direction Air extraction
SEC average -13,1 kWh/(m²*a)
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Power consumption 2,5 W / 5 W
Degree of protection IP X5
Mains cable 4 x 1,5 mm²
Installation site Wall / Ceiling
System type Decentralised
Housing material Synthetic material
Colour Traffic white, similar to RAL 9016
Weight 0,6 kg
Filter class G2
Width 281 mm
Height 281 mm
Depth 33 mm
Airstream temperature at IMax 40 °C
Sound pressure level 15 dB(A) / 35 dB(A) / Specifications in accordance with DIN 18017-3 at an equivalent absorption area AL = 10 m.2
Packing unit 1 piece
Range B
GTIN (EAN) 4012799843610
Article number 0084.0361

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA7, low (dB(A))

20

LWA7, high (dB(A))

39

LWA7= housing and free inlet sound power level in dB.

Accessories / Spare parts

ER-A - Accessories / Spare parts

Specific accessories

Product typeNameArt. No.Price*(EUR)Action
Recessed-mounted housingER GH0084.0350 on request
  • On the notes
Recessed-mounted housingER GH-VWRNew development0093.1564 on request
  • On the notes
Fan insertER EC0084.0360 on request
  • On the notes
Air filter, replacementZF EC+0093.0610 on request
  • On the notes
Air filter, replacementZF EC+ bulk container0093.0611 on request
  • On the notes
Air filter, replacementZF ECD+New development0093.1562 on request
  • On the notes

General accessories

Product typeNameArt. No.Price*(EUR)Action
Radio switchXS 1Discontinued product0157.0344 on request
  • On the notes
Radio receiverXE 10157.0343 on request
  • On the notes
Time delay switchVZ 60157.0820 on request
  • On the notes
Time delay switchVZ 120157.0821 on request
  • On the notes
Time delay switchVZ 24 C0157.0822 on request
  • On the notes
Interval switchVZI 100157.0823 on request
  • On the notes
TimerZS 40157.0088 on request
  • On the notes
HygrostatHY 2300157.0126 on request
  • On the notes
HygrostatHY 230 I0157.0127 on request
  • On the notes

Spare parts

Product typeNameArt. No.Price*(EUR)Action
Cover – upper partABDO ER-A/AK/AHE059.2047.9100 on request
  • On the notes

Product description

Productdescription

ER-A

short description

Cover for ER EC fan insert, standard model

Product description

ER-A – Standard model

  • Standard cover with filter change display.
  • Not speed-controllable.
  • The unit runs in continuous operation at the base load level at 30 m³/h.
  • Full load level on/off via light switch or separate switch.
  • Switching to full load level (60 m³/h) with start delay of approx. 60 sec.
  • Full load overrun time approx. 15 min.
  • Switching option: The base load can be switched on or off by an additional switch (see the wiring diagrams online).

Features

  • Contemporary design.
  • Suitable for continuous operation.
  • IP X5 degree of protection for safety in the bathroom.
  • Colour: traffic white, similar to RAL 9016.
  • For single room air extraction using a single fan.
  • With filter change display.
  • Trouble-free filter change without using tools.
  • It is possible to rotate the cover by ± 5°, to compensate for housings which have been fitted at an angle.
  • Protection class II.
  • Energy-saving EC motor.
  • Motor with thermal overload protection.
  • Maintenance-free, with enclosed ball bearings on both sides.

Table of contents

Wiring diagram

ER-A - Wiring diagram

Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Cookies are used on this website, which are necessary for technical reasons, so that we can present users our offers. A cookie that saves your current privacy settings is also used (selection cookie). With the exception of the above-mentioned selection cookie, technically non-essential cookies and tracking mechanisms that enable us to provide you with an optimal user experience as well as customised offers (marketing cookies and tracking mechanisms) are only used if you have previously approved their use by clicking ACCEPT. Details and options for changing your settings at a later date can be found in our cookie settings.

ACCEPT ALL COOKIES Continue with necessary cookies


Acknowledgements | Data protection