Cover

ER-A

Article number: 0084.0361
Manufacturer: MAICO
Cover for ER EC fan insert, standard model
Application examples: Bathroom, Kitchen, Multiple family unit, Day room, Dining room
ER-A IM0017663.PNG Cover for ER EC fan insert, standard model

Characteristic curve

ER-A - Characteristic curve ER EC with air outlet at rear

I - level 1

II - level 2

  1. Factory settings for base and nominal load level in conjunction with ER-A cover
  2. Alternative settings for base and nominal load levels in conjunction with ER-AK/..-AH/..-AB covers

ER-A - Characteristic curve ER EC with air outlet at side

I - level 1

II - level 2

  1. Factory settings for base and nominal load level in conjunction with ER-A cover
  2. Alternative settings for base and nominal load levels in conjunction with ER-AK/..-AH/..-AB covers

Dimensioned drawing

ER-A - Dimensioned drawing [mm]

Technical data

ER-A - Technical data

Article ER-A
Model Standard
Air flow volume 30 m³/h / 60 m³/h / (Level 1/level 2)
Rotating speed 800 1/min / 1.250 1/min
Air direction Air extraction
SEC average -13,1 kWh/(m²*a)
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Power consumption 2,5 W / 5 W
Degree of protection IP X5
Mains cable 4 / 1,5 mm²
Installation site Wall / Ceiling
System type Decentralised
Housing material Synthetic material
Colour Traffic white, similar to RAL 9016
Weight 0,6 kg
Filter class G2
Width 281 mm
Height 281 mm
Depth 33 mm
Airstream temperature at IMax 40 °C
Sound pressure level 15 dB(A) / 35 dB(A) / Specifications in accordance with DIN 18017-3 at an equivalent absorption area AL = 10 m.2
Packing unit 1 piece
Range B
GTIN (EAN) 4012799843610
Article number 0084.0361

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA7, low (dB(A))

20

LWA7, high (dB(A))

39

LWA7= housing and free inlet sound power level in dB.

Accessories

ER-A - Accessories

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Recessed-mounted housing ER GH 0084.0350 on request
  • On the notes
Fan insert ER EC 0084.0360 on request
  • On the notes
Air filter, replacement ZF EC+ 0093.0610 on request
  • On the notes
Air filter, replacement ZF EC+ bulk container 0093.0611 on request
  • On the notes
Air filter, replacement ZF ECD+ New development 0093.1562 on request
  • On the notes

General accessories

Product type Name Art. No. Price*(EUR) Action
Radio switch XS 1 0157.0344 on request
  • On the notes
Radio receiver XE 1 0157.0343 on request
  • On the notes
Time delay switch VZ 6 0157.0820 on request
  • On the notes
Time delay switch VZ 12 0157.0821 on request
  • On the notes
Time delay switch VZ 24 C 0157.0822 on request
  • On the notes
Interval switch VZI 10 0157.0823 on request
  • On the notes
Timer ZS 4 0157.0088 on request
  • On the notes
Hygrostat HY 230 0157.0126 on request
  • On the notes
Hygrostat HY 230 I 0157.0127 on request
  • On the notes

Product description

Productdescription

ER-A

short description

Cover for ER EC fan insert, standard model

Product description

ER-A – Standard model

  • Standard cover with filter change display.
  • Not speed-controllable.
  • The unit runs in continuous operation at the base load level at 30 m³/h.
  • Full load level on/off via light switch or separate switch.
  • Switching to full load level (60 m³/h) with start delay of approx. 60 sec.
  • Full load overrun time approx. 15 min.
  • Switching option: The base load can be switched on or off by an additional switch (see the wiring diagrams online).

Features

  • Contemporary design.
  • Suitable for continuous operation.
  • IP X5 degree of protection for safety in the bathroom.
  • Colour: traffic white, similar to RAL 9016.
  • For single room air extraction using a single fan.
  • With filter change display.
  • Trouble-free filter change without using tools.
  • It is possible to rotate the cover by ± 5°, to compensate for housings which have been fitted at an angle.
  • Protection class II.
  • Energy-saving EC motor.
  • Motor with thermal overload protection.
  • Maintenance-free, with enclosed ball bearings on both sides.

Table of contents

Wiring diagram

ER-A - Wiring diagram

Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

Search

Here you can search for products, documents, contents pages etc.

Our website uses cookies in order to provide you an optimal service. OK

Acknowledgements Data protection