Cover

ER-AH NFC

New development
Article number: 0084.0461
Cover for ER EC fan insert, model with humidity control and smart time module and NFC interface
Application examples: Bathroom, Kitchen, Multiple family unit, Day room, Dining room
Product data sheet
ER-AH NFC IM0023746.PNG Cover for ER EC fan insert, model with humidity control and smart time module and NFC interface

Characteristic curve

ER-AH NFC - Characteristic curve ER EC 2.1 and ER EC RF17 with ER GH at side air outlet

  1. Factory settings for basic and nominal load levels in conjunction with cover ER-A...
  2. Alternative settings for basic and nominal load levels in conjunction with the ER-AK NFC /..-AH NFC /..-AB NFC covers.

ER-AH NFC - Characteristic curve ER EC 2.1 with ER GH rear exhaust and ER GH AP/APB

  1. Factory settings for basic and nominal load levels in conjunction with cover ER-A...
  2. Alternative settings for basic and nominal load levels in conjunction with the ER-AK NFC /..-AH NFC /..-AB NFC covers.

Dimensioned drawing

ER-AH NFC - Dimensioned drawing [mm]

Technical data

ER-AH NFC - Technical data

Article ER-AH NFC
Model Humidity control with smart time module and NFC parameterisation
Air flow volume 15 m³/h / 20 m³/h / 30 m³/h / 40 m³/h / 60 m³/h / 100 m³/h / Variable settings in 5 m³/h increments from 15 to 100 m³/h adjustable. ER-A: Level 1 = 30 m³/h, Level 2 = 60 m³/h. -AB: ER-AK/ER level 1 and level 2 = variable in 5 m³/h increments from 15 - 100 m³/h. ER-AH: Level 1 = 15-40 m³/h, level 2 = 60-100 m³/h, each adjustable in 5 m³/h increments.
Air direction Air extraction
Degree of protection IP X5
Installation site Wall / ceiling
System type Decentralised
Housing material Synthetic material
Colour Traffic white, similar to RAL 9016
Weight 0,6 kg
Weight including packaging 0,75 kg
Filter class ISO Coarse 30 % (G2)
Width 281 mm
Height 281 mm
Depth 33 mm
Width with packaging 295 mm
Height with packaging 305 mm
Depth with packaging 47 mm
Airstream temperature at IMax 40 °C
Sound pressure level 17 dB(A) / 17 dB(A) / 18 dB(A) / 23 dB(A) / 35 dB(A) / 48 dB(A) / combined with ER GH; 25 dB(A) / 25 dB(A) / 28 dB(A) / 32 dB(A) / 41 dB(A) / 50 dB(A) combined with ER GH AP/APB/ Specification in accordance with DIN 18017-3 with an equivalent absorption area AL = 10 m²
Approval number Z-51.1-478
Packing unit 1 piece
Range B
GTIN (EAN) 4012799844617
Article number 0084.0461

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA, S1 (dB(A))

21

LWA, S2 (dB(A))

21

LWA, S3 (dB(A))

22

LWA, S4 (dB(A))

27

LWA, S5 (dB(A))

39

LWA, S6 (dB(A))

52

Combined with ER GH; 29 dB(A) / 29 dB(A) / 32 dB(A) / 36 dB(A) / 45 dB(A) / 54 dB(A) combined with ER GH AP/APB/ Specification in accordance with DIN 18017-3 with an equivalent absorption area AL = 10 m²

Accessories / Accessories of

ER-AH NFC - Accessories / Accessories of

Specific accessories

is a special accessory of

Product type Name Art. No. Price*(EUR) Action
Fan insert ER EC 2.1 0084.0365 on request
  • On the notes
Fan insert ER EC RF17 0093.0614 on request
  • On the notes
Fan insert ER EC No longer available for delivery 0084.0360 on request
  • On the notes

Product description

Productdescription

ER-AH NFC

short description

Cover for ER EC fan insert, model with humidity control and smart time module and NFC interface

Product description

ER-AH NFC – Model with snart time module, humidity control and NFC interface

  • Barrier-free product as the fan switches itself on and off via the smart humidity control.
  • All settings via the intuitive MAICO@NFC APP, no need to access the circuit board or handle 230 V components.
  • Individual adjustment of the air flow volume (base load 15–40 m³/h, nominal load 40–100 m³/h) is possible.
  • The cover enables the ER EC 2.1 to operate in four stages: base load, nominal load, interval control and humidity control. The air flow rates for each of the four stages can be adjusted individually.
  • Electric plug connector for quickly connecting cover with fan, without tools.
  • Humidity control selectable via the MAICO@NFC app: Linear (automatic) or 2-stage humidity control (manual).
  • Intelligent humidity control with seasonal adjustment. Continuously variable adjustment of the air flow rate between 30 m³/h and the set max. air flow rate based on the relative humidity of the room air. Switch-on humidity does not have to be set. Fan independently monitors the room air humidity and extracts air automatically.
  • Convenient 2-stage humidity control with two freely adjustable set points for relative humidity and individually adjustable air flow rates.
  • On/off switching of the full load level possible via light switch or separate switch, with adjustable start delay (0–120 seconds).
  • Adjustable overrun time for full load level (0–30 min).
  • During manual operation (e.g. using light switch), the set start delay and overrun time apply.
  • Adjustable interval control (0*/1/2/4/6/12, operating time adjustable from 10 to 60 min) for ventilating rooms that are used irregularly.
  • LED filter change indicator with adjustable filter life of 3–12 months.
  • Configuration lock prevents unwanted interference by unauthorised users.
  • The log function of the MAICO@NFC app enables time-saving documentation of configurations and device information.
  • Approval & service reports can be exported directly as PDF files via the MAICO@NFC app.
  • Protection class II.

*Factory settings

Special features

  • Flow-optimised, attractive design
  • Filter can be changed without tools.
  • With filter change indicator.

Features

  • The unit can be run in continuous operation at the base load level.
  • IP X5 degree of protection for safety in the bathroom (protection zone 1).
  • Colour: traffic white, similar to RAL 9016.
  • For single-room air extraction using a single fan.
  • ISO coarse 30 % filter (G2), filter change without tools.
  • It is possible to rotate the cover by ± 5°, to compensate for incorrectly fitted housings.
  • Not speed-controllable.
  • Switching option: The base load can be switched on or off by an additional switch (see the wiring diagrams online).

*Factory settings

Table of contents

Wiring diagram

ER-AH NFC - Wiring diagram

Connection variant 1, full load for ER-A, ER-AK, ER-AH, ER-AB, ER-AK NFC, ER-AH NFC, ER-AB NFC

opt - optional

MS - motor control

Full load can be switched, no base load operation

Connection is made in the housing



Connection variant 2, base load/full load for ER-A, ER-AK, ER-AH, ER-AB, ER-AK NFC, ER-AH NFC, ER-AB NFC

opt - optional

MS - motor control

Full load can be switched with permanent base load

Connection is made in the housing



Connection variant 3, base load/full load for ER-A, ER-AK, ER-AH, ER-AB, ER-AK NFC, ER-AH NFC, ER-AB NFC

opt - optional

MS - motor control

Base and full load can be switched

Connection is made in the housing



Connection variant for interval, humidity, movement for ER-AK, ER-AH, ER-AB, ER-AK NFC, ER-AH NFC, ER-AB NFC

MS - motor control

Connection is made in the housing



Predecessor - successor

ER-AH NFC - Predecessor

Product type Name Art. No. Action
Cover ER-AH No longer available for delivery 0084.0363

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings