Decentralised ventilation unit with heat recovery

geniovent.x 900 F L-G-SO

Article number: 0041.0260
Decentralised RLT air handling unit with very good heat recovery. With cross-counterflow heat exchanger and... more information

Product data sheet
geniovent.x 900 F L-G-SO IM0020318.PNG Decentralised RLT air handling unit with very good heat recovery. With cross-counterflow heat exchanger and preheating register, outside air and outgoing air connections on left, air outlet at top, CO2 sensor integrated in unit. With app for mobile unit control system
geniovent.x 900 F L-G-SO IM0023839.PNG Decentralised RLT air handling unit with very good heat recovery. With cross-counterflow heat exchanger and preheating register, outside air and outgoing air connections on left, air outlet at top, CO2 sensor integrated in unit. With app for mobile unit control system
geniovent.x 900 F L-G-SO IM0019952.PNG Decentralised RLT air handling unit with very good heat recovery. With cross-counterflow heat exchanger and preheating register, outside air and outgoing air connections on left, air outlet at top, CO2 sensor integrated in unit. With app for mobile unit control system
geniovent.x 900 F L-G-SO IM0016031.PNG Decentralised RLT air handling unit with very good heat recovery. With cross-counterflow heat exchanger and preheating register, outside air and outgoing air connections on left, air outlet at top, CO2 sensor integrated in unit. With app for mobile unit control system

Characteristic curve

geniovent.x 900 F L-G-SO - Characteristic curve

  1. Configuration range

Dimensioned drawing

geniovent.x 900 F L-G-SO - Dimensioned drawing [mm]

  1. Exhaust air
  2. Supply air
  3. Outside air
  4. Outgoing air
  5. Revision area
  6. View from above

geniovent.x 900 F L-G-SO - Dimensioned drawing [mm]

  1. Ceiling mounting geniovent.x 600-900 FL. View of the unit from the ceiling.
  2. Optional with fixing bracket rotated by 180°
  3. Designed for ceiling mounting, e.g. with M10 threaded rods.
  4. Optional, the fixing bracket can be moved upwards by 36 mm.
  5. Optional, the fixing bracket can be moved up by 36 mm and rotated by 180°.

Technical data

geniovent.x 900 F L-G-SO - Technical data

Article geniovent.x 900 F L-G-SO
Air flow volume 200 m³/h / 830 m³/h
SFP value 0,29 W/(m³/h)
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Nominal output 186 W
Stand-by power consumption < 1 W
Imax 15 A
Degree of protection IP 40
Installation site Inside
Material Sheet steel, galvanised
Housing material Sheet steel, galvanised
Heat exchanger material Synthetic material
Inner coating material Melamine resin foam with fleece
Colour Pure white, similar to RAL 9010
Weight 200 kg
Weight including packaging 250 kg
Filter class ISO ePM1 50-65% (F7) / ISO ePM10 60% (M5)
Connection diameter 250 mm
Connection diameter of condensation drain 7 mm (inside), 10 mm (outside)
Width 2.115 mm
Height 482 mm
Depth 831 mm
Width with packaging 2.250 mm
Height with packaging 950 mm
Depth with packaging 950 mm
Degree of heat provision 91 %
Heat exchanger construction type Counter current
Bypass Yes
Frost protection integrated 1.5 kW
Supplementary heating optional
Enthalpy heat exchanger No
Antifreeze circuit Yes
Filter monitoring with time control
CO2 regulation (optional) integrated
Smoke gas switch optional
Air quality control (optional) VOC sensor for geniovent.x
Outside air shutters, automatic closing integrated
Presence sensor PIR motion sensor, optional
KNX connection (optional) K-SM
MODBUS interface integrated
BACnet interface integrated
Ethernet interface integrated
Control unit included in scope of delivery. RB-ZF4
Control unit (optional) RLS T1 SYS
EnOcean wireless integration (optional) E-SM
Sound pressure level 35 dB(A) / at 0.7 * Vmax and 20 Pa pressure loss each OSA and OGA, with a room attenuation of approx. 16 dB
Packing unit 1 piece
Range X
GTIN (EAN) 4012799412601
Article number 0041.0260

Product description

Productdescription

geniovent.x 900 F L-G-SO

short description

Decentralised RLT air handling unit with very good heat recovery. With cross-counterflow heat exchanger and preheating register, outside air and outgoing air connections on left, air outlet at top, CO2 sensor integrated in unit. With app for mobile unit control system

Product description

Version

  • With cross-counterflow heat exchanger and preheating register, outside and outgoing air connections to the left, outlet at the top.

Features

  • Decentralised RLT air handling unit with very high heat recovery for use in classrooms, nurseries, offices, doctors' surgeries, shops, meeting rooms and similar.
  • The unit is ceiling-mounted and can also be partially integrated into suspended ceilings.
  • On the room air side, the unit can be fitted with free air discharge and intake as well as with supply and exhaust air connections.
  • Supply air grilles with adjustable air guide slats are already integrated in the unit.
  • The exhaust air opening is located on the left-hand side of the unit.
  • The unit can optionally be fitted with a duct system for the supply and/or exhaust air.
  • The integrated automatically closing shutters for outside and outgoing air close in the event of a power failure or when the unit is switched off.
  • The generously dimensioned heat exchangers with their efficiency of up to approx. 95 % and the very low internal pressure loss ensure low primary energy consumption and high energy gains.
  • All units are fitted with a condensate lift pump.

Housing

  • Design based on VDI 6022 / VDI 3803.
  • High-quality, double-walled housing made of galvanised sheet steel.
  • The insulation is 20-60 mm and consists of a combination of special foams of thermal conductivity group 040.
  • The acoustic insulation material of the interior insulation is made of normally flammable special foam of building material class B2 (DIN 4102-1).
  • The visible areas of the unit’s cladding consist of design panels in the colour pure white, similar to RAL 9010, smooth matt.
  • With the special sliding suspension ('slotted hole'), the units can be mounted directly under the ceiling.

Standard heat exchanger

  • Highly efficient cross-counterflow plate heat exchanger made of plastic (PS) with a maximum degree of heat provision of approx. 95 %

Fans

  • Single inlet, highly energy-efficient fans with backward curved 3D impeller made of fibre-reinforced plastic.
  • Electronically commutated (EC) external rotor motor with integrated electronics and mains adapter.

Control

  • CO2 sensor integrated in the exhaust air (as standard) enables smart demand-driven ventilation operation.
  • The air volume is continuously adjusted to the actual air requirement – this enables maximum efficient ventilation unit operation.
  • Optional external sensors or higher-level building control system possible.
  • Frost protection function depending on the outgoing air temperature via preheater (for units with "E" enthalpy heat exchanger, the preheating register is an optional accessory).
  • All geniovent.x devices can be controlled via application using the integrated LAN interface.
  • The units can therefore be operated on the move or from home, e.g. smartphone.
  • Live reports, user administration, control and adjustment via tablet, laptop and PC.
  • USB connection as a standard feature for commissioning, control system update and service.
  • All units have several operating modes:
    • 2 automatic operating modes (Auto Sensor / Auto Time)
    • 4 manual operating modes (ECO exhaust air / ECO supply air / MANUAL / OFF)
  • Using the time programmes (standard and holiday time programme), not only ventilation levels can be selected but also functions set (e.g. night cooling, flush mode, motion detector mode) or times for demand-driven operation (e.g. sensor mode) chosen.
  • All geniovent.x units are characterised by an energy-optimised frost protection strategy that is adapted to actual requirements.
  • In addition, all units have a multifunction contact for controlling, e.g., an unregulated pump or operating, fault and filter change indicator or preheating register or supplementary heat register or external shutters or cooling.
  • Two input contacts (12 V and 230 V) are available for, e.g., safety shutdown.
  • Various inputs/outputs enable a control connection to other technical devices or switching points (e.g. unit release or fume cupboard operation)

Control system

  • Continuously variable demand-driven adaptation of air volumes.
  • 4 temperature sensors in the outside air, outgoing air, supply air and exhaust air.
  • 1 CO2 sensor in the exhaust air connection.
  • Up to 3 external sensors of different types (CO2, VOC, humidity) or push-button and switching contacts (motion detector, external start/stop, fume cupboard operation and night cooling and flush mode) can be connected.
  • Inputs for safety shutdown via 12V contact or 230V contact (e.g. smoke detector, fire alarm, differential pressureless fireplace).
  • Various inputs and outputs allow the a control connection of the ventilation unit to other technical building devices.

RLS 1 WR control unit

  • Supplied as a simple control panel.
  • Switching the ventilation levels, maintenance display, fault messages.

RLS T1 SYS touchscreen control panel, optional

  • Touchscreen control panel for geniovent.x units with control.
  • Graphic, high-resolution colour TFT display with easy-to-use, intuitive menu navigation.
  • For operation and configuration of various time programmes, operating modes, ventilation levels, automatic night cooling, flush mode, etc. as well as to display status information and alarm messages.
  • Integrated room temperature sensor.
  • Multi-unit capability: up to 10 different geniovent.x units can be controlled with the control unit.
  • Updateable.

Modbus

  • Integrated MODBUS interface (TCP/IP and RTU) enables an integration in the building control system.

BACnet

  • Integrated BACnet interface (TCP/IP) enables an integration in the building control system.

EnOcean

  • Optional EnOcean plug-in module E-SM for integrating the ventilation unit into the "EnOcean world" "www.enocean-alliance.org" Not possible in conjunction with the RLS T1 SYS touchscreen control panel!

KNX

  • Optional KNX plug-in module K-SM allows for connection to building control system, “www.knx.org”.

Additional circuit board ZP 1

  • Optional additional circuit board ZP 1 for controlling e.g. a second heater in the geniovent.x ventilation unit, 3-way shutter or regulated pump or air shutter of a zone control.

Table of contents

Wiring diagram

geniovent.x 900 F L-G-SO - Wiring diagram

geniovent.x circuit board connection diagram

A2 - CDV Controller

A3 - Mains connection 230V/50Hz/16A Fuse protection to be supplied by the customer

W3 - Connection duct (to be supplied by the customer) for external safety device with potential-free contact 12 V/2 A

X01 - Slot for optional EnOcean/KNX communication plug-in module

ZP1 - Expansion board ZP1 control system of supplementary heater (for units with pre- and re-heater)



geniovent.x Connection diagram for condensate pump option

A1 - Condensate pump. Optional. Connection at units with sensitive heat exchanger

A2 - CDV Controller

A3 - Mains adapter. 12 VDC power supply, motion detector optional

V/ZUL - Fan supply air

V/ABL – Fan exhaust air

KL/AL - Shutter outside air

KL/FL - Shutter outgoing air



geniovent.x Connection diagram for pre-heater, re-heater, bypass drive

ABL - Exhaust air temperature sensor

AL - Outside air temperature sensor

A1 - Signal contact potential-free max. 250VAC / 30VDC, 5A ohmic. Observe configuration!

A2 - CDV Controller

BY - Bypass

B1 - Bypass drive (manufacturer: Bosch)

F - Sensor

FL - Outgoing air temperature sensor

H - heater

H1 - heater 1 (pre- or re-heater). Optional

H2 - heater 2 (re-heater). Optional

K - Contact

SL - Control cable

XB* - Plug connection only at unit variant GVX.S! 5-pin plug connection

ZP1 - Expansion board ZP1

ZUL - Supply air temperature sensor



geniovent.x Connection diagram for fans, control panel

A1 - Alternative use as ModBus RTU interface. Note configuration! ModBus RTU cannot be combined with RLS T1 SYS!

A2 - CDV Controller

O - Optional

SL - Control cable

SL V/ABL - Control cable for exhaust air fan

SL V/ZUL – control cable for supply air fan

ZP1 - Expansion board ZP1. Control for supplementary heat register (for units with pre- and re-heater)



geniovent.x Connection diagram CO2 and VOC sensor, break button

A1 - Note sensor input configuration

A2 - CDV Controller

A3 - Internal CO2 sensor

A4 - External CO2 sensor, optional

A5 - External VOC sensor, optional

A6 - Pause Switch, optional

S - Sensor

SL - Control cable

SL/ÖL - Oilflex control cable



geniovent.x Connection diagram External On/Off, BMZ switch-off, KP fault, smoke switch

A1 - Condensate pump malfunction, optional. Connection for appliances with sensitive heat exchangers

A2 - CDV Controller

A3 - Hekatron ORS 144K smoke switch, internal units optional. Power supply via terminals X12

AB/BMZ - BMZ switch-off

F1 - External on/off function, night cooling or flush mode. Release unit / function start via closed potential-free contact. Note sensor input configuration.

S - Sensor

SL/ÖL - Oilflex control cable



geniovent.x Connection diagram for motion detector, control panel, break button, external on/off switch

A1 - Bosch ISC-BPR-W12 motion detector, optional. Power supply via 12VDC power supply unit. Note sensor input 2 configuration. For power supply connection, see page 2.

A2 - CDV Controller

BD - Control panel

F1 - External on/off function, night cooling or flush mode. Release device/function type enabled via closed potential-free contact. Note configuration of sensor input 4.

NT - Mains adapter

PT1 - Pause button optional. Connection of optional components to input. Sensors 3 and 4 only possible if control panel RB ZF 4 is not used. Note configuration of sensor input 3.

S - Sensor

SL - Control cable

SL/ÖL - Oilflex control cable



geniovent.x Connection diagram Cable connections Power supply, touch control panel RLS T1 SYS / standard control panel RB ZF 4

A2 - CDV Controller

BD - Control panel

O - Optional

SL - Control cable

SV - Power supply



geniovent.x Connection diagram Cable connections Optional circuits via control line / USB socket / Ethernet socket

A1 - Connection (SW3-SW9) for external sensors/contacts. For component-dependent assignment, see sheets 5, 6, 7.

Information: When connecting external sensors using wires SW3-SW9, the wires must be connected on the controller side!

A2 - CDV Controller

AS BMZ - Switch-off BMZ

ET/BU – Ethernet/RJ45 socket maico@home/BACnet TCP/ModBus TCP

ME1 - Signal contact potential-free max. 250VAC / 30VDC, 5A ohmic. Please note the configuration!

PK - Patch cable extension Cat 5

SL - Control cable

USB IS - USB / socket commissioning software

VL - Extension



geniovent.x Connection diagram for RLS T1 SYS touch control panel for connecting multiple devices (1 to 10 devices)

A2 - CDV Controller

G - Device

SL - Control cable

TP/DL – Twisted pair data cable

O/BM - RLS T1 SYS. Optional bus master unit

5 - At using the RLS T1 SYS control panel as the system control panel, the maximum length of the RS-485 data cable must be limited to 500 metres.

A maximum of 10 ventilation units can be controlled via an RLS T1 SYS.

At use of the RLS T1 SYS as a system control panel, refer to the operating instructions for the necessary device settings.

In the event of communication disturbances, the data lines (A, B) at both ends must be terminated with 120 ohm resistors.



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings