Pressure and temperature control system

EAT EC

No longer available for delivery
Article number: 0157.0119
Manufacturer: MAICO
Electronic pressure and temperature control system for controlling EC fans in continuously variable manner... more information

Product data sheet
EAT EC IM0015926.PNG Electronic pressure and temperature control system for controlling EC fans in continuously variable manner (including MDR EC and ESR EC)

Characteristic curve

Dimensioned drawing

Technical data

EAT EC - Technical data

Article EAT EC
Operating range 0 - 500 Pa / 0 - 1000 Pa
Type of voltage Alternating current
Rated voltage 230 V
Output signal 0 V - 10 V
Frequency 50 Hz
Degree of protection IP 54
Voltage at the output 1 x 24 AC 2,8 VA
Type of installation Surface-mounted
Housing material Synthetic material
Weight 1,06 kg
Weight including packaging 1,26 kg
Width 188 mm
Height 159 mm
Depth 110 mm
Width with packaging 210 mm
Height with packaging 190 mm
Depth with packaging 130 mm
Ambient temperature 40 °C
Temperature setting range 0 °C up to 40 °C
Packing unit 1 piece
Range E
GTIN (EAN) 4012799571193
Article number 0157.0119

Accessories / Accessories of

EAT EC - Accessories / Accessories of

General accessories

Product type Name Art. No. Price*(EUR) Action
Differential pressure transmitter DS 500 0157.0118 on request
  • On the notes

is a general accessory of

Product type Name Art. No. Price*(EUR) Action
Centrifugal roof fan DRD EC centrifugal roof fans - - -
Sound-insulated ventilation box ESR EC sound-insulated ventilation box - - -
Channel fan DPK EC channel fans - - -
Sound-insulated channel fan DSK EC sound-insulated channel fans - - -
Surface-mounted exhaust air element, fire protection Surface-mounted exhaust air element, Centro fire protection - - -
Centrifugal roof fan DRD EC centrifugal roof fans - - -
Sound-insulated ventilation box EKR FU sound-insulated exhaust air box - - -
Exhaust air element Centro exhaust air element - - -
Sound-insulated ventilation box ESR -2 EC sound-insulated ventilation box - - -
Centrifugal roof fan MDR 18 EC 0087.0020 on request
  • On the notes
Centrifugal roof fan MDR 22 EC 0087.0022 on request
  • On the notes
Centrifugal roof fan MDR 25 EC 0087.0024 on request
  • On the notes
Centrifugal roof fan MDR 31 EC 0087.0026 on request
  • On the notes
Centrifugal roof fan MDR 35 EC 0087.0028 on request
  • On the notes
Centrifugal roof fan MDR 40 EC 0087.0029 on request
  • On the notes
Centrifugal roof fan MDR 45 EC 0087.0030 on request
  • On the notes
Centrifugal roof fan EHD 10 EC Discontinued product 0073.0559 on request
  • On the notes
Centrifugal roof fan EHD 12 EC Discontinued product 0073.0560 on request
  • On the notes
Centrifugal roof fan EHD 15 EC Discontinued product 0073.0561 on request
  • On the notes
Centrifugal roof fan EHD 16 EC Discontinued product 0073.0562 on request
  • On the notes
Centrifugal roof fan EHD 20 EC Discontinued product 0073.0563 on request
  • On the notes
Centrifugal roof fan EHD 25 EC Discontinued product 0073.0564 on request
  • On the notes
Centrifugal roof fan EHD 31 EC 0073.0565 on request
  • On the notes
Centrifugal roof fan EHD 15/2 EC New development 0073.0591 on request
  • On the notes

Product description

Productdescription

EAT EC

short description

Electronic pressure and temperature control system for controlling EC fans in continuously variable manner (including MDR EC and ESR EC)

Product description

  • Versatile electronic control system for controlling one or two EC fans in continuously variable manner.
  • Depending on the sensors connected, temperature, differential temperature or pressure control is possible.
  • Five operating modes available: Automatic/manual mode/continuous operation/inactive or off.
  • Different control inputs for temperature sensors and also active sensors, such as pressure sensors with 0-10 V signal.
  • Temperature sensor included in the scope of delivery.
  • Two controlled output signals of 0-10 V as control signal for one or two EC fans.
  • Option for connecting shutter servomotors (230 V or 24 V).
  • 2 pressure values can be specified (day/night).
  • Alarm contact.
  • Timer with daily and weekly program.
  • Quick and easy start-up thanks to illuminated two-line digital display with plain text display and membrane keypad.
  • Very little power consumption.

Table of contents

Wiring diagram

EAT EC - Wiring diagram

Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings