Axial roof fan

EZD 50/6 B

Article number: 0087.0211
Manufacturer: MAICO
Axial roof fan, horizontal air outlet, DN 500, alternating current
Application examples: Production facility, Workplace, Commercial premises, Restaurant, Showroom
Product data sheet
EZD 50/6 B IM0009965.PNG Axial roof fan, horizontal air outlet, DN 500, alternating current

Characteristic curve

EZD 50/6 B - Characteristic curve

Dimensioned drawing

EZD 50/6 B - Dimensioned drawing [mm]

Technical data

EZD 50/6 B - Technical data

Article EZD 50/6 B
Air flow volume 4.040 m³/h
Air volumenom 2.560 m³/h / in opt. efficiency
Pressure pfs, nom 55 Pa / in opt. efficiency
Rotating speed nnom 945 1/min / in opt. efficiency
Rotating speed 947 1/min
Impeller type axial
Speed controllable
Reversing capacity
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Nominal output 245 W / in opt. efficiency
Inom 1,1 A / in opt. efficiency
Imax 1,3 A
Degree of protection IP 55
Insulation class B
Installation site Roof
Installation position vertical
Material Sheet steel, galvanised
Colour Silver
Weight 33 kg
Weight including packaging 40 kg
Nominal size 500 mm
Width 940 mm
Height 940 mm
Depth 420 mm
Width with packaging 941 mm
Height with packaging 941 mm
Depth with packaging 510 mm
Airstream temperature at nominal current -20 °C up to 60 °C
Airstream temperature at IMax -20 °C up to 60 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799872115
Article number 0087.0211
Article EZD 50/6 B
Total efficiency η 30,1 %
Measurement category C
Efficiency category static
Efficiency level N 40,3
Year of manufacture see rating plate
Manufacturer’s name / official registration number / manufacturer's place of establishment Maico Elektroapparate-Fabrik GmbH / Freiburg registration court, HRB 601233 / Villingen-Schwenningen
Art. No. 0087.0211
PBEP / Air volumeBEP / Pfs, BEP 0,245 kW / 4.350 m³/h / 61 Pa
nBEP 945 1/min
Specific ratio ≈ 1
Information about dismantling and disposal see mounting instructions
Information about installation, operation and repairs see mounting instructions
Objects used to measure efficiency which are not described by the measurement category -
Sound power levelLWA7 79 dB(A)

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA7, S5 (dB(A))

50

64

71

71

75

72

67

57

79

LWA7= housing and free inlet sound power level in dB.

Accessories

EZD 50/6 B - Accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
Control shutter JRE 50 0151.0394 on request
  • On the notes
Servomotor MS 8 0157.0760 on request
  • On the notes
Servomotor MS 8 P 0157.0761 on request
  • On the notes
Protective grille, metal SG 50 0150.0120 on request
  • On the notes
Flexible coupling ELA 50 0092.0271 on request
  • On the notes
Flexible cuff EL 50 0092.0092 on request
  • On the notes
Counter flange GF 50 0056.0008 on request
  • On the notes
Counter socket GS 50 0055.0174 on request
  • On the notes
Suction nozzle AD 50 0180.0625 on request
  • On the notes
Socket sound absorber SD 50 0092.0344 on request
  • On the notes
Main switch, service switch HS 3 0157.0736 on request
  • On the notes
Rotary switch DS 10 0157.0410 on request
  • On the notes
Reversing switch W 1 0157.0101 on request
  • On the notes
Reversing switch WU 1 0157.0102 on request
  • On the notes
Contactor US 16 T 0157.0769 on request
  • On the notes
Speed controller STX 2,5 0157.1562 on request
  • On the notes
Speed controller, distribution board STSX 2,5 0157.1564 on request
  • On the notes
Reversing switch UWK 1 0157.0817 on request
  • On the notes
5-step transformer TRE 1,6-2 0157.0158 on request
  • On the notes
5-step transformer, control cabinet TRE 1,6 S-2 0157.0162 on request
  • On the notes
5-step switch for TRE...S -2/ TR...S-2 5-step transformers ESS 20 0157.0749 on request
  • On the notes
Thermostat THR 10 Discontinued product 0157.0774 on request
  • On the notes
Thermostat THR 10-1 0157.0191 on request
  • On the notes
Thermostat TH 10 0157.0764 on request
  • On the notes
Thermostat TH 16 0157.0748 on request
  • On the notes
Thermostat THD 10 Discontinued product 0157.0775 on request
  • On the notes
Temperature control system EAT 6 G/1 0157.0808 on request
  • On the notes
Temperature control system EAT 6 TG Discontinued product 0157.0755 on request
  • On the notes
Air flow monitor LW 9 0157.0779 on request
  • On the notes
Hygrostat HY 230 0157.0126 on request
  • On the notes
Hygrostat HY 230 I 0157.0127 on request
  • On the notes
Air quality controller EAQ 10/1 Discontinued product 0157.0777 on request
  • On the notes
Roof socket for flat roofs SO 50 0093.0364 on request
  • On the notes
Roof socket for pitched roofs SDS 50 0093.1029 on request
  • On the notes
Roof socket for corrugated and trapezoidal roofs SOWT 50 0093.1032 on request
  • On the notes
Speed controller ST 2,5 No longer available for delivery 0157.0811 on request
  • On the notes
Speed controller STU 2,5 No longer available for delivery 0157.0815 on request
  • On the notes
Speed controller, distribution board STS 2,5 No longer available for delivery 0157.0255 on request
  • On the notes
Speed controller, reversing switch STW 2,5 No longer available for delivery 0016.0142 on request
  • On the notes
Temperature control system, power module EALT 6 No longer available for delivery 0157.0756 on request
  • On the notes
Hygrostat HY 10 AP No longer available for delivery 0157.0358 on request
  • On the notes
Hygrostat HY 10 UP No longer available for delivery 0157.0357 on request
  • On the notes

Product description

Productdescription

EZD 50/6 B

short description

Axial roof fan, horizontal air outlet, DN 500, alternating current

Product description

Brief description

  • Housing, base plate, intake nozzle and rain protection cover made of galvanised sheet steel.
  • Galvanized protective grille on the discharge side, protection against accidental contact in accordance with DIN EN ISO 13857.
  • Sturdy eyebolts enable transport by crane.
  • 8-blade impeller made of glass-fibre reinforced polyamide.
  • Thermal overload protection as a standard feature.
  • Fans meet the requirements of the European Ecodesign Directive (EC) No.327/2011 Directive 2009/125/EC.
  • Vibration-free running due to dynamically balanced impeller and motor (shaft-rotor), according to quality class 6.3, DIN ISO 1940, part 1.
  • High efficiency on the ventilation side, low operating noise.
  • Increased durability due to high-quality materials such as quiet ball bearings.
  • Fans are maintenance-free.
  • Reversible operation of the fans possible.
  • Customer-specific special voltages available, as special designs, on request and at extra cost.
  • Can be switched to ventilation or air extraction with separate switch (exception EZD ... E).

Air flow direction

  • The air flow direction is marked.
  • Standard exhaust air mode, air flow direction with air blown across motor.

AC motor

  • Asynchronous motor.
  • Rated voltage 230 V, 50 Hz.
  • Fans “... B” and “... D”: Capacitor motors with operating capacitor in terminal box.
  • Fans “... E”: Shaded-pole motors.
  • Degree of protection for EZD... D and ... E IP 54.
  • Degree of protection for EZD... B IP 55.
  • Speed controllable.
  • Units can be steplessly controlled with optional speed controllers or they can be steplessly switched with an optional 5-step transformer.
  • Reversible. Exception: For fans with shaded-pole motor (“... E”).
  • Reversing mode: The volumetric flow is reduced by approx. 35 % with abnormal air flow direction.
  • Thermal overload protection as a standard feature.

Electrical connection

  • Connecting cable, approx. 1.7 m long.

Safety information

  • The fan may be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN ISO 13857, e.g., with Maico SG protective grille.
  • A proper fixed installation in a horizontal installation position, a permanent electrical supply cable and correct air supply via shaft or duct is stipulated.

Special versions

  • The following special versions are available on request, at an extra cost:
    • Special voltages and frequencies.
    • Fans with enhanced anti-corrosion protection.
    • Impellers made of aluminium.
  • Information on operation at temperatures occasionally below -20°C available upon request.
  • If operating with frequency converters, the factory must be consulted.
  • Feasibility must be checked in each case.

Table of contents

Wiring diagram

EZD 50/6 B - Wiring diagram

EZD..B left-hand operation (air extraction) = standard


EZD..B right-hand operation (ventilation)


EZD ../.. B with STX.../STTSX... speed controller


EZD ..B with STW speed controller


EZD ..B with STX/STSX.. speed controller and UWK 1 reversing switch


Predecessor - successor

EZD 50/6 B - Predecessor

Product type Name Art. No. Action
Axial roof fan EZD50-6A No longer available for delivery 0087.0411
  • On the notes

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings